  IMPORTANT SAFETY INSTRUCTIONS 

(SAVE THESE INSTRUCTIONS)

 

This manual contains important safety instructions. Please read and follow all instructions carefully 

during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, 

install, or operate your UPS. 

 

CAUTION! 

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled 

indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and 

humidity range.) 

CAUTION! 

To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid 

exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space 

heaters or furnaces. 

CAUTION!

 Do not attach non-computer-related items, such as medical equipment, life-support 

equipment, microwave ovens, or vacuum cleaners to UPS. 

CAUTION!

 Do not plug the UPS input into its own output. 

CAUTION! 

Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any 

other liquid-containing vessels on or near the unit. 

CAUTION!

 In the event of an emergency, press the OFF button and disconnect the power cord from the 

AC power supply to properly disable the UPS. 

CAUTION!

 Do not attach a power strip or surge suppressor to the UPS. 

CAUTION!

 If the UPS is with metal chassis, for safety purpose, grounding is a must during UPS 

installation in order to reduce leakage current below 3.5mA.Attention hazardous through electric shock. 

Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through 

supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at 

the quick connectors of the battery when maintenance or service work inside the UPS is necessary. 

CAUTION!

 Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery. 

CAUTION!

 Servicing of batteries should be performed or supervised by personnel knowledgeable of 

batteries and the required precautions. Keep unauthorized personnel away from batteries. 

CAUTION! 

When replacing the batteries, use the same number and type of batteries. 

CAUTION!

 Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the 

battery or batteries. Released electrolyte is harmful to the skin and eyes. 

CAUTION! 

Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

CAUTION! 

A battery can present a risk of electric shock and high short circuit current. The following 

precaution should be observed before replacing batteries: (1) Remove watches, rings, or other metal 

objects.(2) Use tools with insulated handles.(3) Wear rubber gloves and boots.(4) Do not lay tools or 

metal parts on top of batteries. (5) Disconnect charging source prior to connecting or disconnecting 

batteries terminal. 

 

INSTALLING YOUR UPS SYSTEM 

 

UNPACKING 

 

Inspect the UPS upon receipt. The box should contain the following: 

(1)UPS Unit

1; (2) Power Cord 

1; (3)USB Cable

1; (4)Telephone communication cable x1; (5)User 

Manual

1; (6)Management software Disk

 

OVERVIEW 

 

The Value1200ELCD/1500ELCD/2200ELCD provides automatic voltage regulation for inconsistent 

utility power, and provides battery backup during power outages. The 

Value1200ELCD/1500ELCD/2200ELCD ensures consistent power to your computer system and its 

included software will automatically save your open files and shut down your computer system during a 

utility power loss. 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

 

1. 

Insure that the equipment plugged into the battery power-supplied outlets does not exceed the 
UPS unit’s rated capacity (1200VA/720W for Value1200ELCD, 1500VA/900W for Value1500ELCD, 

2200VA/1320W for Value2200ELCD). If rated unit capacities are exceeded, an overload condition 

may occur and cause the UPS unit to shut down or the circuit breaker strip.

 

2. 

There are many factors that can affect the amount of power that your computer system will require.   
For optimal system performance keep the load below 80% of the unit’s rated capacity. 

 

HARDWARE INSTALLATION GUIDE 

 

1. 

Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 

8 hours is recommended to ensure that the battery's maximum charge capacity is achieved. 

Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit 

plugged into an AC outlet. The unit will charge in both the on and off position. 

2. 

With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered 

data storage device (Zip drive, Jazz drive, Tape drive, etc. into the battery power supplied outlets. 

DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large 

electrical device into the battery power supplied outlets. The power demands of these 

devices will overload and possibly damage the unit.

 

3. 

Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch 

outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical 

demands (e.g. air conditioner, refrigerator, copier, etc. Avoid using extension cords. 

4. 

Depress the power switch to turn the unit on. The power on indicator light will illuminate and the 

unit will "beep". 

5. 

If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To 

correct this, turn the UPS off and unplug at least one piece of equipment from the battery power 

supplied outlets. Wait 10 seconds. Make sure the circuit breaker is depressed and then turn the 

UPS on. 

6. 

To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

7. 

To store your UPS for an extended period, cover it and store with the battery fully charged. 

Recharge the battery every three months to ensure battery life. 

   

     

   

BASIC OPERATION 

 

FRONT PANEL DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. 

LCD Display 

The LCD will display the UPS status including input voltage, output voltage, runtime, percentage of 
load and battery…etc.

 

 

2. 

Power On/Off Switch 

           

Press the power switch to turn the UPS ON or OFF. 

 

3. 

LCD Function Selected Switch 

The switch can be used to select the LCD display contents Including input/output voltage and 

estimated run time, etc. 

 

REAR PANEL DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. 

AC Inlet

   

Connect to utility power through the input power cord 

 

2. 

Input Circuit Breaker 

The circuit breaker provides optimal overload protection.

 

 

3. 

AC outlet 

The UPS provides outlets for connected equipment to insure temporary uninterrupted operation 

during a power failure and against surges and spikes. 

*Note: 5 outlet types available including: 

Schuko, UK, French, Australian and ASEAN type. 

 

4. 

Communication Protection Ports

 

Communication protection ports will protect any standard modem, fax, telephone line, or network 

cable. 

 

5. 

Serial Port to PC

 

 

This port allows connection and communicates from the DB-9 serial on the computer to the UPS 

unit. The UPS communicates its status to the 

PowerPanel

®

 Personal Edition

 software. 

 

 

 

 

 

 

 

 

 

           

Schuko 

 