BAS34U24V

CyberShield UPSs are designed to provide a local power solution for

cable telephon

y

, wireless local loop (WLL), and fiber to the home

(FTTH) broadband equipment.

IMPORTANT SAFETY WARNINGS 

(SAVE THESE INSTRUCTIONS)

This manual contains important instructions regarding the installation and operation of this device.
Read this manual thoroughly before attempting to unpack, install, or operate this device.

OVERVIEW

LED INDICATOR

LED Indicator

 

Ethernet Port LED Indicator
AC Power Cord Connector
DC Output Connector (5W/0.21A)

 

Universal (Serial) Port

 

Ethernet Port

External Battery Connector

 

DC Output Connector(24W/1A)

 

1
2
3
4
5
6
7
8

Rail Slot

Locking Clip

9

10

1

2

9

10

3

4

5 6

7

8

BATTERY REPLACEMENT AND INSTALLATION 

BAS34U24V AND MOUNTING DETAILS 

Step 1:

a. Upside down the unit. 

b. Loosen four screws from enclosure. 

Step 2:

a. Tack away the battery cover.

Step 3:

a. Remove the battery from enclosure.

Step 4:

a. Disconnect the battery cable connector.

b. Install a new battery by connecting the

    cable connector.

a.

b.

Step 5:

a. Put the battery back into the compartment.

Step 6:

a. Replace the battery cover. 

Step 7:

a. Tighten up four screws from the enclosure.

Mounting on DIN Rail

Removing from DIN Rail

Step 8:

a. Upside down the unit to resume normal 

    operation. 

Step 9:

a. Connect the AC cable to activate the unit.

User’s Manual for

CyberShield

STATUS

DC

BATTERY

ETHERNET

PORT

 

Green

Red

Green

Green

Indicates normal mode of operation.
Indicates the battery is supplying the power.

1.Battery mode : LED is on.

2.Line mode : LED is off.

3.Low battery : LED is blinking.

1.Battery replacement required : LED is on.

2.Battery is absent : LED is blinking.

Yellow

The Remote Management Card is connected to the Network.

Indicates the Remote Management Card power.

1.Power on : LED is on.

2.Power off : LED is off.

3.Receiving/transmitting data packet : LED is blinking.

4.Reset finished : LED is blinking.

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

Do not store batteries or battery-powered devices in hot places — elevated temperatures 

can lead to capacity loss, leakage, or rupture. 

Do not dispose of batteries in a fire. The battery may explode if improperly disposed.

Recycle the battery in accordance with local regulations.

 

When replacing the battery, the replacement should have the same rating as followers,

18650 Lithium-ion Rechargeable Battery, 14.8V/6500mAh.

Do not remove the cover, except to service the battery, to reduce the risk of electric shock. 

To reduce the risk of electric shock, do not remove the cover. No user serviceable parts

inside including the battery. Please contact us or our dealer directly.

Do not disassemble, crush, puncture, or otherwise damage batteries. This can result in 

leakage or rupture. 

Do not open or mutilate the battery. Released material is harmful to the skin and eyes. It 

maybe toxic.

Never block or insert any objects into the keyholes or other openings of the UPS.

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled 

indoor area, free of conductive contaminants. (Please see specifications for acceptable 

temperature and humidity range). 

This unit must be DIN rail. Do not use the unit unless it is mounted correctly.

The unit is for indoor use only. Please avoid direct sunlight exposure.

Runtimes based on testing fully-charged, new batteries at normal operating conditions.  

Runtime curve is approximate and varies based on battery age, level of charge at test, 

environment, and other variables.

As long as utility power is on, you may leave the UPS and connected equipment on while replacing 

a new battery. (For service personnel reference only)

Indicator

Color

Description

Number

Condition