The use of the PowerPanel Plus™ software is optional.
The UPS unit will provide full surge suppression and
battery backup without the software. You must use the software if you wish to have the automatic shutdown feature.
POWERPANEL PLUS™ MAIN MENU
1.
Log Button:
Click on the log button to
open the Log Window.
2.
Power Button:
Clicking on the power
button will stop the software.
3.
Minimize Button:
Click this button to
minimize the software.
4.
Setup Button:
Click the setup button to
open the Setup Window.
5.
Model:
This shows the model of the
CyberPower UPS that is being used.
6.
Version:
This shows the hardware version.
7.
Status Bar:
The area display messages
about the status of the software.
8.
Schedule Button:
Click this button to
access the Schedule Window.
POWERPANEL PLUS™ MAIN WINDOW DESCRIPTION
1. Input
Voltage:
This reading shows the current input voltage of the utility power. The input normally
appears in green, but will turn red if the input voltage is lower than 85v or higher than 150v.
2. Battery
Level:
This indicator displays the current charge on the battery. The indicator will display a red
color when a power failure occurs.
3. Frequency:
This indicator displays the frequency of the utility power.
4. Scheduled
On:
PowerPanel Plus™ can be scheduled to turn your computer system on. It can only be
set when a
Scheduled Off
is also set.
Scheduled On
settings that are set to occur within seven days
will be displayed. When the UPS is in standby, after the
Scheduled Off
, the using battery and check
battery indicators will flash in rotation.
5. Final
Countdown:
When PowerPanel Plus™ detects that the utility voltage is below 85 volts or above
150 volts, the
Final Countdown
will begin. When the countdown reaches zero, PowerPanel Plus™ will
save and close any open applications, and
then shut down the operating system in an
intelligent and orderly manner.
6.
Approximate Backup Time:
This indicator
shows the
approximate
amount of backup
time that is available, based upon the battery
capacity and the load on the system. This
indicator can appear in red, yellow, or green,
depending upon the number of minutes
available.
7. Scheduled
Off:
PowerPanel Plus™ can be
set to automatically shutdown the computer
system at a user specified time.
Scheduled
Off
settings that are set to occur within seven days will be displayed.
8. Temperature:
This indicator displays the internal operating temperature of the unit. If the temperature
exceeds 158°F (70°C), the indicator will change from green to red.
9. Load
Level:
This indicator shows the % of capacity of the battery outlets that is currently being used. If
the load level exceeds 90%, the indicator will change to a red color.
10. Output
Voltage:
This indicator shows the output voltage of the UPS.