background image

1
2

3

4

5

6

7

8

9

10

11

12

Automatic Voltage Regulators

increase low or decrease high voltage to a computer 
safe 110/120 volts. The AVR automatically provides 
battery back-up power if line voltage drops below 90 
volts or exceeds 140 volts.

AVR

INCONSISTENT

UTILITY POWER

CONSISTENT 

SAFE POWER

Min

V

ESTIMATE RUN_TIME

INPUT

LOAD CAPACITY

BATT. CAPACITY

OUTPUT

BATTERY

A.V.R

FAULT

NORMAL

NORMAL

SILENT

OVER

LOAD

100

IN

OUT

CP900AVRLCD / CP1100AVRLCD/ 

CP1350AVRLCD / CP1500AVRLCD

User’s Manual

K01-0000002-01

In purchasing a CP900AVRLCD / CP1100AVRLCD / CP1350AVRLCD / CP1500AVRLCD in the United States or Canada, the original end 
user  receives  a  Limited  Warranty  and  Connected  Equipment  Guarantee  from  Cyber  Power  Systems  (USA),  Inc.  (for  ease  of  reading, 
referred to as "CyberPower"). The Limited Warranty and the Connected Equipment Guarantee are intended to be the original end-user's 
exclusive rights and remedies. The Limited Warranty and the Connected Equipment are separate, all though they are related.

Limited  Warranty.  The  original  end  user  (referred  to  as  the  "Initial  Customer")  receives  an  express  limited  warranty  (referred  to  as  the 
"Limited Warranty") for the CP900AVRLCD / CP1100AVRLCD / CP1350AVRLCD / CP1500AVRLCD purchased from CyberPower (referred 
to as the "Product"). The Limited Warranty is for the Product itself. The terms of the Limited Warranty are explained below.

Connected Equipment Guarantee. CyberPower also provides the Initial Customer with protection in the event that the Product is not free 
from  defects  in  materials  and  workmanship,  and  certain  equipment  connected  to  the  Product  is  damaged  (the  "Connected  Equipment 
Guarantee"). The Connected Equipment Guarantee protects the Initial Customer for damage to equipment plugged into the Product. The 
terms of the Connected Equipment Guarantee are explained below.

The Limited Warranty and the Connected Equipment Guarantee are subject to the terms set forth below. Additionally, State or local law may 
adjust the terms of the Limited Warranty or the Connected Equipment Guarantee or may impose additional obligations, or additional "implied 
warranties." To the extent necessary to comply with those laws, the terms of the Limited Warranty and the Connected Equipment Guarantee 
should be read to adjust to those requirements only to the extent necessary to comply with such local law.

If you are an Initial Customer, you are asked to read the following terms and conditions carefully before using the Product. By using the 
Product you consent to be bound by and become a party to the Limited Warranty and Connected Equipment Guarantee. If you do not agree 
to the terms and conditions of the Limited Warranty and Connected Equipment Guarantee, you should return the Product for a full refund 
prior to using it.

REGISTRATION

CyberPower requests that you complete and return the Warranty Registration Card enclosed with the Product or register the Product at its 
website (www.cyberpowersystems.com) to establish that you are the Initial Customer of the Product, and therefore entitled coverage under 
the Limited Warranty and the Connected Equipment Guarantee. (Registration is not required for Limited Warranty coverage, but note if you 
do not complete a registration card you will be required to provide proof of purchase, as described below, to have the benefits of this Limited 
Warranty.)

LIMITED WARRANTY

CyberPower warrants to you, the Initial Purchaser, that the Product will be free from defects in material and workmanship for three years 
from the date of original purchase, subject to the terms of this Limited Warranty.

Any  Implied  Warranty  of  Merchantability  or  for  Fitness  for  a  Particular  Purpose,  if  applicable  to  the  Product,  is  limited  in  duration  to  the 
period of ownership by the Initial Customer. This provision shall NOT create any Implied Warranty or Merchantability or of Fitness for a 
Particular Purpose that would not otherwise apply to the Product. 

NOTE: Some jurisdictions do not allow limitations on how long an 

implied warranty lasts, so the above limitation may not apply to you.

To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty.

Exclusive Remedies Under Limited Warranty.

Your exclusive remedy and CyberPower's' sole obligations are as follows for the Product:
If  (a)  the  CyberPower  Product  you  purchased  and  still  own  is  defective  in  material  or  workmanship  under  this  Limited  Warranty  or  any 
applicable  warranty  imposed  by  law,  and  (b)  all  Limited  Warranty  requirements  have  been  met,  CyberPower  will  repair  or  replace  the 
product if it proves to be defective in material or workmanship during the Warranty Period. 

Making a Limited Warranty Claim.

To make a Limited Warranty claim on a Product, you must do the following:
1. Complete and return the CyberPower Warranty Registration Card, or provide reasonable proof of purchase (for example, a sales receipt) 
that  establishes  you  as  the  Initial  Customer  (the  original  end-user  consumer  purchaser)  of  the  Product  and  prove  that  the  Product  was 
purchased within three (3) years of the event for which you want to make a claim for warranty service.
2. Call CyberPower at (952) 403-9500 or (877) 297-6937 (toll free), write to CyberPower at 5555 12th Ave. East, Suite 110, Shakopee, MN 
55379, or e-mail CyberPower at [email protected], within ten (10) days of the event for which you want to make a claim.
3. When you contact CyberPower, identify the Product, the Purchase Date, and request Return Materials Authorization (RMA) information 
from CyberPower.
4. Pack and ship the Product to CyberPower as instructed in your RMA. Show the RMA code on the shipping label or include it with the 
Product. 

You MUST prepay all shipping costs and you are responsible for packaging and shipment.

CyberPower will inspect and examine the Product within ten (10) days of receipt. If the Product is not as warranted, CyberPower will repair 

(SAVE THESE INSTRUCTIONS)

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the 
unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

CAUTION!   

To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity  controlled  indoor  area  free  of  conductive 

contaminants.  (Please see specifications for acceptable temperature and humidity range).

CAUTION! 

 To reduce the risk of electric shock, do not remove the cover except to service the battery.  No user serviceable parts inside 

except for battery.

CAUTION!  

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.

CAUTION!  

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.  Do not plug into an outlet that is not 

grounded.  If you need to de-energize this equipment, turn off and unplug the unit.

CAUTION!  

To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a 

computer component.

CAUTION!  

To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in 

accordance with the national Code, ANSI / NFPA 70.

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!  

CyberPower Systems does not sell products for life support or medical 

applications.    DO  NOT  use  in  any  circumstance  that  would  affect  operation  or  safety  of  any  life  support  equipment  or  with  any  medical 
applications or patient care.

DO  NOT  USE  WITH  OR  NEAR  AQUARIUMS!   

To  reduce  the  risk  of  fire  or  electric  shock,  do  not  use  with  or  near  an  aquarium.   

Condensation from the aquarium can cause the unit to short out.

DO NOT USE WITH LASER PRINTERS!  

The power demands of these devices will overload and possibly damage the unit.

UNPACKING

Inspect the UPS upon receipt. The box should contain the following:
(1) UPS unit; (1) User’s manual; (1) PowerPanel

®

 Personal Edition software CD; (1) USB device cable; (1) Telephone cable; (1) Warranty 

registration card; (1) Coaxial Cable 

OVERVIEW

The CP900AVRLCD / CP1100AVRLCD / CP1350AVRLCD / CP1500AVRLCD provides automatic voltage 
regulation  for  inconsistent  utility  power.  The  CP900AVRLCD  /  CP1100AVRLCD  /  CP1350AVRLCD  / 
CP1500AVRLCD features 890/1080/1500/1500 Joules of surge protection, and provides battery backup 
during  power  outages.    The  CP900AVRLCD  /  CP1100AVRLCD  /  CP1350AVRLCD  /  CP1500AVRLCD 
ensures consistent power to your computer system and its included software will automatically save your 
open files and shutdown your computer system during a utility power loss.

AUTOMATIC VOLTAGE REGULATOR

The CP900AVRLCD / CP1100AVRLCD / CP1350AVRLCD / CP1500AVRLCD stabilize inconsistent utility power.  The incoming utility power 
may be damaging to important data files, but with Automatic Voltage Regulation, the computer will not experience damaging voltage levels.  
An Automatic Voltage Regulator automatically increases low or decreases high voltage to a consistent, computer safe 110v/120v.  The unit’s 
powerful sealed lead-acid batteries will provide power only if the incoming voltage drops below 90v or increases above 140v.

HARDWARE INSTALLATION GUIDE

1. Your new UPS may be used immediately upon receipt.  However, recharging the batteries for at least 16 hours is recommended to ensure 

that  the  battery’s  maximum  charge  capacity  is  achieved.   A  loss  of  charge  may  occur  during  shipping  and  storage.    To  recharge  the 
batteries, simply leave the unit plugged into an AC outlet.  The unit will charge in both the ON as well as the OFF position.

2. With the UPS unit off and unplugged, connect your computer, monitor, and any externally powered data storage device (Zip drive, Jazz 

drive, Tape drive, etc…) into the battery power supplied outlets.  Plug your peripheral equipment (printer, scanner, speakers) into the full-
time surge protection outlets.  

DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum or other large electrical 

device into the UPS.  The power demands of these devices will overload and possibly damage the unit.

3. To surge protect a network connection, connect a network cable from the wall jack outlet to the IN jack of the UPS. 

Then connect a network cable from the OUT jack on the UPS to the network device.

4. Plug the UPS into a 2 pole, 3 wire grounding receptacle (wall outlet).  Make sure the wall branch outlet is protected by a fuse or circuit 

breaker and does not service equipment with large electrical demands (e.g. refrigerator, copier, etc…).  The warranty prohibits the use of 
extension cords, outlet strips, and surge strips.

5. Press the power switch to turn the unit on.  The power on indicator light will illuminate and the unit will “beep” once.
6. If an overload is detected, an audible alarm will sound and the unit will emit one long beep.  To correct this, turn the UPS off and unplug at 

least one piece of equipment from the battery power supplied outlets.  Wait 10 seconds.  Make sure the circuit breaker is depressed and 
then turn the UPS on.

7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
8. To  store  your  UPS  for  an  extended  period,  cover  it  and  store  with  the  battery  fully 

charged.  While in storage recharge the battery every three months to ensure battery 
life.

HOW TO CONFIGURE THE OSX UPS 

FUNCTION IN ENERGY SAVER

1. With the computer and the UPS off, connect the USB cable that was included with the 

unit to an available USB port on the computer. 

2. Turn the UPS on and start the computer. 
3. Once the computer has started open system preferences. 
4. In system preferences click on Energy Saver.
5. Choose Settings for UPS and adjust your runtimes.

DESCRIPTION

1    Power Switch 

Used as the master on/off switch for equipment connected to the battery power supplied outlets.

2    Power On Indicator

This  LED  is  under  the  power  switch.  It  illuminates  when  the  utility  condition  is  normal  and  the  UPS  outlets  are 
providing power, free of surges and spikes. 

  3    LCD Module Display.

High resolution and intelligent LCD display shows all the UPS information with icons and messages. For more information please check the 
“Definitions for Illuminated LCD Indicators” section.  

  4    LCD Display Toggle/Selected Switch

The switch can be used to select the LCD display contents including Input Voltage, Output Voltage and Estimated Run 
Time. The toggle frequency is set to one time per second. Holding the switch for more than two seconds while running 
on battery will silence the buzzer.  

  5    Battery and Surge Protected Outlets

The  unit  has  four  battery  powered/surge  protected  outlets  for  connected  equipment  and  ensures  temporary 
uninterrupted operation of your equipment during a power failure.

  6    Full-Time Surge Protection Outlets

The unit has four always on surge suppression outlets.

  7    Electrical Wiring Fault Indicator

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.  If 
this is illuminated, user is advised to disconnect all electrical equipment from the outlet and have an electrician check to ensure the outlet is 
properly wired. The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet.

  8    Communication Protection Ports

Communication protection ports will protect any standard modem, fax , telephone line, broadband network or Ethernet connection.

  9    Circuit Breaker

Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection. 

 10    Serial/USB Ports to PC

The ports allow connection and communication from the USB or DB-9 serial port on the computer to the UPS unit.  The USB port will 
communicate with PowerPanel

®

 Personal Edition and the  DB-9 port is for use with a serial cable and the Microsoft

®

 UPS Service.

Note: Only one of these two ports can be used to communicate with your computer at one time.
Note: To install PowerPanel

®

 Personal Edition Software the computer will need Microsoft

®

 Internet Explorer 5.0 or higher installed.

Note: If using the Serial Port please read the directions to configure the Microsoft UPS service on our website 

http://www.cyberpowersystems.com/ups_service.asp

 . If you need a serial cable please contact CyberPower technical support at

[email protected]

 

 11    Coax/Cable/DSS Surge Protection

The Coax/Cable/DSS surge protection ports will protect any cable modem, CATV converter, or DSS receiver.

 12    Outlets Designed for AC Adapters

The unit has four outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets.

CAUTION! 

Read  and  follow  the  IMPORTANT  SAFETY  INSTRUCTIONS  before  servicing  the  battery.    Service  the  battery  under  the 

supervision of personnel knowledgeable of batteries and their precautions.

CAUTION! 

Use only the specified type of battery.  See your dealer for replacement batteries.

CAUTION! 

The  battery  may  present  a  risk  of  electrical  shock.    Do  not  dispose  of  battery  in  a  fire  as  it  may  explode.  Follow  all  local 

ordinances regarding proper disposal of batteries.  Almost any retailer that sells lead-acid batteries collects used batteries for recycling, as 
required by most state laws.

CAUTION! 

Do not open or mutilate the batteries.  Released electrolyte is harmful to skin and eyes and may be toxic.

CAUTION! 

A battery can present a high risk of short circuit current and electrical shock.  Take the following precautions before replacing the 

battery:
1.Remove all watches, rings or other metal objects.
2.Only use tools with insulated handles.
3.Do not lay tools or metal parts on top of battery or any terminals.
4.Wear rubber gloves and boots.
5.Determine if the battery is inadvertently grounded. If grounded, remove the source of ground. 

CONTACT WITH GROUNDED BATTERY

   CAN RESULT IN ELECTRICAL SHOCK!

Model

CP900AVRLCD

CP1100AVRLCD

 

CP1350AVRLCD

CP1500AVRLCD

Capacity

900VA / 560W

1100VA / 640W

 

1350VA / 810W

1500VA / 900W

Input Voltage on Utility

90V to 140V

Input Frequency

60 Hz ± 3 Hz

On-Battery Output Voltage

120Vac ± 5%

Transfer Time

4ms Typical

Max. Load for UPS Outlets

900VA / 560W

1000VA / 580W

 

1285VA / 750W

1500VA / 900W

Max. Load for Full-Time 
Surge Protection outlets (8 Outlets)

12 Amps

On-Battery Output Wave Form

Simulated Sine Wave Form

Operating Temperature

+ 32°F to 95° F / 0° C to 35° C

Operating Relative Humidity

0 to 95% NON-CONDENSING

Size (L x W x H)

                             

13 5/16” x 4” x 9 7/8”

                               

33.8 x 10.0 x 24.9cm

Net Weight

22.2 lbs

24.4 lbs

                                    25.6 lbs

Typical Battery Recharge Time

8 hours typical from total discharge

Typical Battery Life

                     3 to 6 years, depending on number of discharge/recharge cycles

Battery Type

                        Spill-proof, Maintenance-free, sealed lead-acid

Safety Approvals

UL1778(UPS), cUL107., FCC/DoC Class B

Model

iMac G4

Desktop PC  

Desktop PC

Desktop PC 

Desktop PC

with 17”LCD Monitor

with 19”LCD Monitor

with 21”LCD Monitor

with CRT Monitor

CP900AVRLCD

105 minutes

79 minutes

51 minutes

47 minutes

40 minutes

CP1100AVRLCD

145 minutes

79 minutes

51 minutes

47 minutes

40 minutes

CP1350AVRLCD

148 minutes

89 minutes

57 minutes

52 minutes

47 minutes

CP1500AVRLCD

170 minutes

90 minutes

57 minutes

55 minutes

49 minutes

IMPORTANT SAFETY WARNINGS

INSTALLING YOUR UPS SYSTEM

BASIC OPERATION

TROUBLE SHOOTING

DEFINITIONS FOR ILLUMINATED LED INDICATORS

Limited Warranty and Connected Equipment Guarantee

TECHNICAL SPECIFICATIONS

  1. Turn off and unplug all connected equipment.
  2. Turn the UPS off and unplug it from the AC power source.
  3. Turn the UPS upside down.
  4. Remove the retaining screw.
  5. Slide the battery compartment cover (front panel) completely off of the unit.
  6. Remove the batteries from the compartment.
  7. Disconnect the battery wires from the batteries.
  8. Install the replacement batteries by connecting the red wire and black wire to the same color 

wires from the battery pack.

  9. Put the batteries back into the compartment.
10. Slide back the battery compartment cover and tighten the retaining screw. 
11. Recharge the UPS for 8-16 hours to fully charge the battery. 

The LCD display indicates a variety of UPS 

operational conditions. All descriptions apply 

when the UPS is plugged into an AC outlet 

and turned on or when the UPS is on battery.  

INPUT  voltage  meter: 

This  meter  measures  the  AC  voltage  that  the  UPS  system  is 

receiving from the utility wall outlet. The UPS is designed, through the use of automatic 
voltage  regulation,  to  continuously  supply  connected  equipment  with  stable,  110/120 
output voltage. In the event of a complete power loss, severe brownout, or over-voltage, 
the  UPS  relies  on  its  internal  battery  to  supply  consistent  110/120  output  voltage.  The 
INPUT voltage meter can be used as a diagnostic tool to identify poor-quality input power.

OUTPUT voltage meter: 

This meter measures, in real time, the AC voltage that the UPS 

system is providing to the computer, such as normal line mode, AVR mode, and battery 
back up mode.

Note: The OUTPUT voltage meter shows the status of the battery back up outlets.

ESTIMATE RUN TIME: 

This displays the run time estimate of the UPS with the current 

battery capacity and load.  

NORMAL icon: 

This icon appears when the UPS is working under normal conditions.

BATTERY icon: 

During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to 

indicate the UPS is operating from its internal batteries. During a prolonged brownout or blackout, the alarm will sound continuously (and the 
BATT.CAPACITY meter shows one 20% capacity segment shaded) to indicate the UPS’s batteries are nearly out of power. You should save 
files and turm off your equipment immediately.

AVR

 

(Automatic Voltage Regulator) icon:

 This icon appears whenever your UPS is automatically correcting low AC line voltage without 

using battery power. This is a normal, automatic operation of your UPS, and no action is required on your part. 

SILENT MODE icon:

This icon appears whenever the UPS is in silent mode. The buzzer does not  beep during silent mode until the battery 

reaches low capacity.

OVER LOAD icon: 

This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To clear the overload, 

unplug some of your equipment from the battery-supplied outlets until the icon turns off and the alarm stops.

FAULT icon: 

This  icon  appears  if  there  is  a  problem  with  the  UPS.  Contact  CyberPower  Systems  at  [email protected]  for 

further help and support.

BATT.  CAPACITY  meter: 

This  meter  displays  the  approximate  charge  level  (in  20%  increments)  of  the  UPS’s  internal  battery.  During  a 

blackout or severe brownout, the UPS switches to battery power, the BATTERY icon appears, and the charge level decreases.

LOAD CAPACITY meter: 

This meter displays the approximate output load level (in 20% increments) of the UPS’s battery outlets.

Alarm

Condition

On

Off

Off

Normal

On

On/Off

2 beeps 

per 30 seconds

On

On/Off

Rapid beeps

On

On/Off

Long beeps

On

On

None

POWER

ON

WIRING

FAULT

Utility failure—The UPS is providing battery power to the battery power-

supplied outlets.

Utility failure—The UPS is providing battery power.The rapid beeps mean 

that the battery will run out of charge within a few minutes.

Battery overload—Occurs in the battery power-supplied outlets. Turn off 

the UPS and unplug at least one piece of equipment from the UPS. Wait 

10 seconds, press the circuit breaker reset button, then turn the UPS on.   

Electrical wiring fault—This means there’s a wiring problem within the 

utility AC power outlet. A wiring problem could be a bad ground, missed 

ground, or reversed wiring. You should disconnect all equipment from 

the outlet and have it checked by an electrician.  

REPLACING THE BATTERY

DEFINITIONS FOR ILLUMINATED LCD INDICATORS

REMINDER: 

Batteries  are  consider  HAZARDOUS  WASTE  and  must  be  disposed  of  properly.    Almost  any  retailer  that  sells  lead-acid 

batteries collects used batteries for recycling, as required by most state laws.

Additional troubleshooting information can be found at

www.cyberpowersystems.com/support.htm

Problem

Possible Cause

Solution

Full-time surge protection outlets 

stop providing power to equipment. 

Circuit breaker button is projecting 

from the side of the unit.

Circuit breaker has 

tripped due to an 

overload.

Turn the UPS off and unplug at least one piece of equipment.  

Wait 10 seconds, reset the circuit breaker by depressing the 

button, and then turn the UPS on.

The UPS does not perform 

expected runtime.

Recharge the battery by leaving the UPS plugged in.

Contact CyberPower Systems about replacement batteries at 

[email protected]

Battery is slightly worn out.

Battery not fully charged.

The UPS will not turn on.

The on/off switch is designed 

to prevent damage by rapidly 

turning it off and on.

Turn the UPS off.  Wait 10 seconds and then turn the UPS on.

The unit is not connected to an 

AC outlet.

The unit must be connected to a 110/120v 60Hz outlet.

The battery is worn out.

Contact CyberPower Systems about replacement batteries at 

[email protected]

Mechanical problem.

Contact CyberPower Systems at 

[email protected]

PowerPanel

®

 Personal Edition is 

inactive (all icons are gray).

The USB cable is not 

connected.

Connect the USB cable to the UPS unit and an open USB port 

on the back of the computer.  You must use the cable that 

came with the unit.

The USB cable is connected 

to the wrong port.

Check the back of the computer for an additional USB port.  

Move the cable to this port.

The unit is not providing 

battery power.

Shutdown your computer and turn the UPS off.  Wait 10 

seconds and turn the UPS back on.  This should reset the unit.

EXPECTED RUNTIME IN MINUTES

(Due to the differences in computer components, the runtime will vary.)

or replace the Product and return it to you at CyberPower's expense, or, if CyberPower is unable to or decides not to repair or replace the 
Product (if defective) within a reasonable time, CyberPower will refund to you the full purchase price you paid for the Product (purchase 
receipt showing price paid is required).

CONNECTED EQUIPMENT GUARANTEE

If  you  are  the  Initial  Purchaser  and  the  Product  is  still  covered  by  the  Limited  Warranty,  the  Connected  Equipment  Guarantee  provides 
protection for damage to equipment connected to the Product ("Connected Equipment"), subject to certain terms and limitations.
The Connected Equipment Guarantee is not "first dollar" coverage. It is secondary.  If you have any other source of payment for your loss, 
such as insurance, another warranty, or an extended warranty or purchase protection plan (“Primary Coverage”), CyberPower’ will pay only 
to the extent that that the Primary Coverage does not cover the loss.  CyberPower's obligation is reduced by any amounts that you are 
entitled to recover from the Primary Coverage, whether or not you make a claim for recovery under any applicable Primary Coverage.
The  Limited  Warranty  does  not  cover  Connected  Equipment,  but  as  is  explained  below,  to  be  covered  under  the  Connected  Equipment 
Guarantee, the Connected Equipment must have been damaged due to a failure of the Product. The Connected Equipment must have been 
damaged due to a defect in materials or workmanship of the Product
In  the  event  of  damage  to  the  Connected  Equipment,  your  exclusive  remedies,  and  CyberPower’s  sole  obligations,  are  as  follows  for 
Connected Equipment. If (a) the Product purchased and owned by you is defective in material or workmanship; (b) the Limited Warranty         
requirements  have  been  met  (except  that  the  three  year  limitation  of  the  Limited  Warranty  does  not  limit  the  Connected  Equipment 
Guarantee, which is for the lifetime of the Product), and; (c) none of the limitations or exclusions on warranty coverage apply (or than the 
three year limit), CyberPower will (as CyberPower elects, as permitted by law), repair, replace, or pay the Agreed Damage Amount (defined 
below)  for,  the  item(s)  of  your  electronic  equipment  directly  and  properly  connected  to  the  product  (the  "Connected  Equipment")  if  that 
Connected Equipment is (x) damaged by AC power line transients, spikes, or surges on properly installed, grounded, and code-compliant 
120 volt power lines in the United States and Canada, or by transients, surges or spikes on standard telephone equipment lines, or Base 
10/100T  Ethernet  lines  that  are  properly  installed  and  connected  (a  "Power  Disturbance")  and  (y)  is  directly  plugged  into  and  properly 
connected  to  a  CyberPower  Product  in  its  original  condition  which  is  properly  operated  when  a  Power  Disturbance  passes  through  the 
CyberPower Product and (y.1) exhausts the protection capacity of the CyberPower Product or (y.2) damages the CyberPower Product. This 
provision sets out the only liability of any character of CyberPower for direct, indirect, special, consequential, and/or incidental damages 
under our Limited Warranty, applies only to Connected Equipment, and all such Liability is limited to the Agreed Damage Amount.

Making a Connected Equipment Guarantee Claim.

To make a Warranty claim for damage to Connected Equipment under the Connected Equipment Guarantee, you must do the following:
1.  Complete  and  return  the  CyberPower  Warranty  card  or  provide  reasonable  proof  of  purchase,  for  example,  a  sales  receipt  that 
establishes you as the original end-user consumer purchaser of the Product.
2. Call CyberPower at (952) 403-9500 or (877) 297-6937 (toll free), write to CyberPower at 5555 12th Ave East, Suite 110, Shakopee, MN 
55379, or e-mail CyberPower at [email protected] within ten (10) days of the date of the event for which you wish to make a 
claim for warranty service.
3. When you contact CyberPower, identify the Product, the Purchase Date, and the item(s) of Connected Equipment. Have information on 
all applicable insurance or other resources of recovery/payment that are available to the Initial Customer and the name of the power utility 
supplier for the location of the Connected Equipment and Request a Claim Number.
4. Pack and ship the product to CyberPower and, if requested, the item(s) of Connected Equipment, a repair cost estimate for the damage 
to the Connected Equipment, and all claim forms that CyberPower provides to you. Show the Claim Number on the shipping label or include 
it with the product. 

Initial Customer shall prepay all shipping costs, must pay the cost of the repair estimate, and is responsible for 

packaging and shipment.

CyberPower’s Duties.

CyberPower  will  inspect  and  examine  the  Product  and  the  item(s)  of  Connected  Equipment  (or  at  CyberPower's  election,  your  written 
statement and repair cost estimate for those item(s)). You must return the product for inspection.
If  the  damage  to  Connected  Equipment  is  covered  by  the  Connected  Equipment  Guarantee,  CyberPower  will  (in  addition  to  Limited 
Warranty  remedies  for  the  CyberPower  Product  itself)  repair  (or  pay  the  costs  of  repair)  or  replace  the  Connected  Equipment  or,  at  the 
option of CyberPower, as permitted by law, pay to the Initial Customer the "Agreed Damage Amount" (up to the aggregate limits stated 
below) for all item(s) of Initial Customer's Connected Equipment. The "Agreed Damage Amount" for all items of Initial Customer's Connected 
Equipment shall be the lesser of the amount determined under Clause (1) or (2) below, reduced by any amounts described in Clause (3) 
below:
1. The fair market value of the Connected Equipment as established by the lower of (a) the price list of Orion Blue Book on the date of 
occurrence (or if such price list is no longer published, a published or announced price list reasonably selected by CyberPower), or (b) the 
average price the same or similar items are being sold for on 
E-bay, or (c) the lowest price the same or similar items can be purchased for in the United States; or 
2. The aggregate ceiling amount for all Connected Equipment: CyberPower CP900AVRLCD - $300,000.00. CP1100AVRLCD - $375,000.00. 
CP1350AVRLCD - $425,000.00. CP1500AVRLCD - $500,000.00.
3. The amount(s) of all payment you have or are entitled to receive from insurance, other warranties, extended warranties, or from other 
sources or persons for the Connected Equipment or damage to such equipment so that CyberPower’s maximum liability shall be reduced to 
reflect all such other payments or sources of recovery 
If CyberPower replaces the connected equipment or pays to the Initial Customer the Agreed Damage Amount, the Initial Customer shall 
transfer ownership of all item(s) to CyberPower without warranty by the Initial Customer, but free of lien or other interest.

CONDITIONS COMMON TO THE LIMITED WARRANTY AND THE CONNECTED EQUIPMENT GUARANTEE

The  Limited  Warranty  and  the  Connected  Equipment  Guarantee  are  the  only  and  the  exclusive  express  warranty  of  CyberPower  with 
respect to the Product. This exclusion of other express warranties applies to written and oral express warranties.

LIMITATION: THE LIMITED WARRANTY AND THE CONNECTED EQUIPMENT GUARANTEE DOES NOT COVER

The Limited Warranty and the Connected Equipment Guarantee are intended to exclusive rights and remedies and replace any other rights, 
to the extent allowed by law.
1.  As  to  the  CyberPower  Product,  the  limited  warranty  does  not  cover  or  apply  to:  misuse,  modification,  operation  or  storage  outside 
environmental limits for the Products, in transit, in shipment, or in storage, damage or deterioration, improper operation or maintenance, or 
use with items or equipment not designed or intended for use with the product.
2.  As  to  Connected  Equipment,  the  Connected  Equipment  Guarantee  covers  only  damage  within  the  specific  terms  of  the  Connected 
Equipment Guarantee to Connected Equipment (and only up to the applicable aggregate ceiling amount). 
3. The Connected Equipment Guarantee does not cover damage to Connected Equipment or apply if the Product has been operated in a 
failure mode or not in compliance with CyberPower operating instructions and manuals, or if the Connected Equipment has been operated 
in a failure mode or not in compliance with the instructions and manuals of its manufacturer/vendor.

The Limited Warranty and the Connected Equipment Guarantee Do Not Apply Unless The Initial Customer:

1. Has properly connected the Product and the Connected Equipment to properly wired and grounded outlets (including compliance with 
electrical and safety codes of the most current electrical code (ANS/NFPA 70), without the use of any adapters, extension cords or other 
connectors.
2. Has provided a suitable and proper environment for use and installation of the Product and Connected Equipment.
3. Has properly installed and operated the CyberPower Product and Connected equipment.
4. Has operated the Product at all times within the limitations on the Product’s VA capacity as stated in this User Manual.

CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following:

1. Loss of or damage to data, records, or software or the restoration of data or records, or the reinstallation of software.
2. Damage from causes other than AC Power Line Transients, spikes, or surges on properly installed, grounded and code-compliant 120 
volt power lines in the United States and Canada; transients, surges or spikes on standard telephone land lines, PBX telephone equipment 
lines  or  Base  10T  Ethernet  lines,  when  properly  installed  and  connected.  (This  exclusion  applies,  for  example,  to  fluctuations  in  data 
transmission or reception, by CATV or RF transmission or fluctuations, or by transients in such transmission.
3. Damage from any circumstance described as excluded above with respect to the product.
4. Damages from fire, flood, wind, rain, rising water, leakage or breakage of plumbing, abuse, misuse or alteration of either the product or 
the Connected Equipment.

Exclusion of Consequential and Other Damages.

The sole and exclusive remedies of the Initial Customer are those provided by the Limited Warranty and Connected Equipment Guarantee. 
CyberPower  excludes  any  liability  for  personal  injury  under  the  Limited  Warranty  and  Connected  Equipment  Guarantee.  CyberPower 
excludes any liability for direct, indirect, special, incidental or consequential damages, whether for damage to or loss of property [EXCEPT 
FOR  (AND  ONLY  FOR)  the  specific  limited  agreement  of  CYBERPOWER  to  provide  certain  warranty  benefits  regarding  "Connected 
Equipment" under the "CYBERPOWER Connected Equipment Guarantee"], loss of profits, business interruption, or loss of information or 
data.  NOTE:  Some  States  or  Provinces  do  not  allow  the  exclusion  or  limitation  of  incidental  or  consequential  damages,  so  the  above 
limitation may not apply to you.

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES.

CyberPower  does  not  sell  the  Products  for  use  in  high-risk  activities.  The  Product  is  not  designed  or  intended  for  use  in  hazardous 
environments requiring fail-safe performance, including the operation of nuclear facilities, aircraft navigation or communication systems, air 
traffic control, weapons systems, life support or medical applications or for use in any circumstance in which the failure of the Product could 
lead directly to death, personal injury, or severe physical or property damage, or that would affect operation or safety of any medical or life 
support device (collectively, "High Risk Activities"). CyberPower expressly disclaims any express or implied warranty of fitness for High Risk 
Activities. CyberPower does not authorize use of any of its products use in any High Risk Activities. 

ANY SUCH USE IS IMPROPER AND IS A MISUSE OF CYBERPOWER PRODUCTS.

The Limited Warranty and the Connected Equipment Guarantee are governed by the laws of the United States and the State of Minnesota, 
without reference to conflict of law principles. The application of the United Nations Convention of Contracts for the International Sale of 
Goods is expressly excluded.
Contact Information: CyberPower's address is 5555 12th Ave East, Suite 110, Shakopee, MN 55379 and its phone number is (952) 403-
9500  or  Toll-free:  (877)  297-6937.  CyberPower  is  the  warrantor  under  this  Limited  Warranty.  You  may  also  contact  CyberPower  on  the 
Internet at www.cyberpowersystems.com.

FCC Notice

This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules.  
These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  in  residential  installation.    This  equipment 
generates,  uses  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the  instructions,  may  cause 
harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If 
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by one or more of the following measures:  (1) Reorient or relocate the receiving 
antenna.  (2) Increase the separation between the equipment and receiver.  (3) Connect the equipment into an outlet on a circuit different 
from  that  to  which  the  receiver  is  connected.      (4)  Consult  the  dealer  or  an  experienced  radio/TV  technician  for  help.    Any  special 
accessories needed for compliance must be specified in the instruction.  

CAUTION:  

A shielded-type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio 

and television reception.  It is essential that only the supplied power cord be used.  Use only shielded cables to connect I/O devices to this 
equipment. 

CAUTION:  

Any changes or modifications not expressly approved by the guarantee of this device could void the user’s authority to operate 

the equipment.

TO REPLACE THE BATTERY

Reviews: