Positioning / Leveling the SE505 System
Adjust the height of the system to align with incoming and outgoing conveyor sections. System
height can be configured at a standard height or can be lowered 5 cm (2 inch.) by repositioning
the leveling foot block. Both methods are described in the following section.
Standard Conveyor Height
The standard height configuration allows the SE505 conveyor to be positioned from 91–104 cm
(36–41 inch) high.
➢
To adjust the system height (standard height)
1. Ensure that the floor is free of debris and the area provides adequate clearance on all sides of
the unit.
2. Push the SE505 unit into position, lining up the front rails of the incoming and outgoing
conveyor sections.
3. To adjust the leveling feet, loosen the locking nut with a wrench and then turn the
adjustment nut.
●
Turn the nut clockwise to raise the unit
●
Turn the nut counter-clockwise to lower the unit
Figure 30.
Leveling Foot
4. Use a level or machine height measurements to make sure that the system is level.
5. Manually slide a panel through the incoming and outgoing conveyor sections to make sure
that the SE505 conveyor rail is properly aligned. The panel should pass from the upstream
conveyor through the SE505 system and on to the downstream conveyor without any
resistance.
6. After adjusting the leveling feet, tighten the locking nuts.
i
Note:
Do not bolt the SE505 conveyors to incoming and outgoing conveyor sections. Vibrations
from other machines may impact SE505 performance.
Locking nut
Adjustment nut
Summary of Contents for SE505
Page 1: ...SE505 Hardware Manual ...
Page 6: ...Contents vi SE505 Hardware Manual ...
Page 10: ...x SE505 Hardware Manual ...
Page 72: ...Chapter 3 Installation 62 SE505 Hardware Manual ...
Page 168: ...Chapter 4 Replacing Components and Preventive Maintenance 158 SE505 Hardware Manual ...
Page 180: ...Index 170 SE505 Hardware Manual ...