background image

Quick Reference 

930342E

© 2014, CyberData Corporation, ALL RIGHTS RESERVED

© 2014, CyberData Corporation, ALL RIGHTS RESERVED

930342E

Quick Reference 

Connections

Mounting the Enclosure 

Contacting CyberData

1-Sense (+)

2-GND

3-Relay COM

4-Relay NO
5-Line-In(+)

6-Line-In(-)

7-Line-Out(+)

8-Line-Out(-)

9-Spkr Out(+)

10-Spkr Out (-)

CLASS II WIRING

Speaker Connection

Line-Out Connection

Relay Connection

Sensor Connection

Line-In Connection

To mount the enclosure:

1. Prepare holes for the screws.

2. Plug in the power adapter and use the 

green 

Power

 light to verify that the 

power is on.

3. Plug the Ethernet cable into the V2 

Loudspeaker Amplifier. The yellow 

Link

 

light verifies the network connection.

4. For wall mounting, use the three 

#6 x 1-1/4-inch Pan Head Phillip screws 
to secure the speaker.

071057A

PHILLIP SCREW (3x)

#6x1 1/4" PAN HEAD

#6 PLASTIC ANCHOR (3x)

151014

531032

Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Web:

 

http://www.cyberdata.net/support/contactsupportvoip.php

RMA Dept: (831) 373-2601 ext. 136
Email: [email protected]
RMA Status:

 

http://www.cyberdata.net/support/rmastatus.html

Warranty information is available at:
Web:

 

http://www.cyberdata.net/support/warranty/index.html

Corporate Headquarters

CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA

Phone: 831-373-2601
Fax: 831-373-4193
www.CyberData.net

Getting Started

Download the 

VoIP V2 Loudspeaker Amplifier Operations Guide

 PDF file from the 

Documents

 page at:

http://www.cyberdata.net/products/voip/digitalanalog/loudspeakerampv2/docs.html

Create a plan for the locations of your paging amplifiers.

WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.

WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the 

installation instructions.

WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.

WARNING: The V2 Loudspeaker Amplifier enclosure is not rated for any AC voltages!

Wiring the 125V AC Plug

V2 Loudspeaker Amplifier Parts

Parameter

Factory Default Setting

IP Addressing

DHCP

IP Address

a

a. Default if there is not a DHCP server present.

10.10.10.10

Web Access Username

admin

Web Access Password

admin

Subnet Mask

a

255.0.0.0

Default Gateway

a

10.0.0.1

The green wire with the yellow stripe is a ground connection for Electrostatic Discharge (ESD) protection,
and should not be removed.

To wire the 125V AC plug, consult a licensed electrician and the local building codes in your area.

(1) Assembly

(1) Wall Mounting Kit

(3) #6 Plastic Anchors

(3) #6 x 1-1/4-inch Pan Head Phillip Screws

(1) Enclosure

(1) CAT 5e/CAT6 cable

Additional Parts

View Inside of the Enclosure

(1) PoE Power Injector

Installation Quick Reference

VoIP V2 Loudspeaker Amplifier 
(AC-Powered)

SIP Compliant

011095

The IP Endpoint Company

Reviews: