T
ESTSING THE
S
ERIAL
P
ORTS
The 2 serial ports of the DNC 600S are SUB-D 9P, plugs J5 and J6.
Introduce and verify that the transmission parameters are programmed
as follows:
PARAMETERS RS232 / DIVERS
. . .
-- COMPUTER LINK –-
106 BAUD RATE 4800 STOP 1.0
PARITY ODD(1) EVEN(2) _ BITS 8
PROTOCOLE _ BCC ___
Set a test loopback connector on the serial line connector RS232 to be
tested.
Press
the
key to
The message
RUN
must flash.
start the test.
To stop the test, press the
(STOP) key.
If you wish as well to test the
Connect the transmission cable to the DNC and fit a short circuiting
loopback connector on the other end
cable:
of the cable to be tested.
est Loopback Connector
T
Pin 2 (RXD) wired to pin 3 (TXD)
Pin 4 (DTR) wired to pin 6 (DSR)
Pin 7 (RTS) wired to pin 8 (CTS)
RS 232 Transmission Cable
The shield must be
connected on the metallic
hood of the
Sub-D plugs.
APPENDIX H: TRANSFER
PAGE 79
Summary of Contents for DNC 600S
Page 3: ......
Page 5: ...This page has been left blank intentionally PAGE II USER GUIDE DNC 60 PS ...
Page 9: ...This page has been left blank intentionally PAGE VI LICENCE AGREEMENT ...
Page 13: ...PAGE 4 USER GUIDE DNC 600S This page has been left blank intentionally ...
Page 32: ...APPENDIX A CONVENTIONS PAGE 23 This page has been left blank intentionally ...
Page 62: ...This page has been left blank intentionally APPENDIX F PROGRAMMING WITH L ALPHA PAGE 53 ...
Page 63: ...PAGE 54 USER GUIDE DNC 600S ...
Page 86: ...APPENDIX G MISCELLANEAOUS PAGE 77 lank intentionally This page has been left b ...
Page 90: ...APPENDIX H TRANSFER PAGE 81 This page has been left blank intentionally ...
Page 112: ...ACCESSORIES ACCESSORIES PAGE 103 This page has intentionally been left blank ...
Page 116: ...INDEX PAGE 107 150BW Warranty III ...