![Cyan L-AMP Engineering And Planning Manual Download Page 26](http://html.mh-extra.com/html/cyan/l-amp/l-amp_engineering-and-planning-manual_2701312026.webp)
Cyan Z-Series Engineering and Planning Guide
Release 5.0
P a g e
26
© 2013 Cyan, Inc. – All Rights Reserved.
700-0023-05-00 Rev. 1
-48V Z22 Shelf
Line Cards
Slots
A
B
1
2
CEMi
X
X
LAD-2P or LAD-2G
X
PME-216i (-48V)
X
X
PME-412
X
X
MSE-1482
X
X
SFT-8
X
X
2.5G-LME4
X
X
SFT-10G16
X
X
DTM-8 / DTM-8G
X
X
DTM-100G
X
X
FLX-216i
X
X
WSS-402
X
X
WSS-404
X
X
Important! – At least one Z-Series line card must be installed in slots 1 and/or 2 of the -48V
Z22 shelf to act as the shelf manager.
Note: A dual-slot DTM-100G line card installed in slots 1 and 2 does NOT provide shelf manager
redundancy.
1.1.3 CEMi Controller Card: +24 Volt
The CEMi +24V model is identical in function to the -48V CEMi controller card, but is designed to operate
in 24-volt applications supported by the Z22 +24V shelf model. Voltage range for the +24 volt CEMi card is
18 to 30 Vdc.
For CEMi controller card feature details and specifications, see
Common Equipment Module (CEMi)
starting on page 33.
1.1.4 Z22 Physical
•
Height: 3.5" / 88.9 mm (2
RU)
•
Width: 19.00" / 483 mm
•
Depth: 14.85" / 377 mm
•
Weight: 15 lbs. / 6.8 kg (with 2 CEMi cards and fan tray)
•
Operating temperature: -40°F to +149°F / -40°C to +65°C (I-Temp)