6.4 Foot pedal control
6.5 Emergency buttons
A. Foot pedal control.
Press the start feeding of the two rubber heating rollers.
Release the pedal to stop the rotation of the two rubber
rollers.
It is possible to activate/deactivate pedal operation
from the control panel (see par. 6.3).
Roller feeding speed is set on the control panel (see
par. 6.3).
Emergency button
When pressed, causes deactivation of the functional processes (immediate stop of all machine
movements and equipment dependent on it).
To reset operation, turn it clockwise and the button automatically comes back up.
The emergency button must not be used as an ordinary operating cycle stop command.
When they are hot, the high temperature rollers can deform if left stationary for prolonged periods of time.
They must always be kept in rotation for cooling.
If they need to be stopped, for example for an emergency stop, restart them as soon as possible.
When they are hot, the high temperature rollers can deform if stopped and left in contact with one another.
If they need to be stopped, move them away from one another.
When heated to a temperature exceeding 60°C, the high temperature rollers must always be in motion.
EXPRESS
USE AND MAINTENANCE MANUAL
EN
MANUAL CODE: 771027010
REVISION: 0
DATE: 29/11/2018
FLEXA S.r.l. - Partial or whole reproduction prohibited without authorisation
37
Summary of Contents for CWTLAM-160
Page 2: ......
Page 59: ......
Page 60: ...FLEXA Sr l reserves the right to make technical changes to this manual without prior notice...