5
SSR/CHS/001
TABLE 5
PTP Synchronization specification
PARAMETER
MIN.
TYP.
MAX.
UNITS
CONDITION/DETAILS
Time accuracy
Measured over the full temperature range with temperature
changing at up to 1°C per minute.
mean error
–
10
40
ns
Mean of PPS errors calculated over ±60 seconds from any
reading.
instantaneous error
–
20
250
ns
After synchronization is achieved, with no loss of connection
to Grandmaster.
Time to synchronize
Measured from a power-up of the test chassis, using a
Meinberg M600 IEEE 1588 Grandmaster, supplying PTPv1
messages to the SSR/CHS/001 via OnTime T208 switch,
configured in IEEE 1588 transparent mode.
1 μs
–
50
–
s
250 ns
–
75
–
s
TABLE 6
PTP grandmaster
PARAMETER
MIN.
TYP.
MAX.
UNITS
CONDITION/DETAILS
Grandmaster accuracy
digital IRIG
-2
–
2
μs
GPS
-2
–
2
μs
Error relative to precise reference clock, GPS signal from
antenna which has a clear view of the sky.
PTP address
IP address
–
224.0.0.
129,
224.0.0.
107
–
–
PTP, UDP port numbers are 319 and 320. PTPv2 in P2P
mode uses additional IP address (224.0.0.107) for delay
measurement.
PTP sync interval
1588v1
–
2
–
s
Sync interval when operating as a PTPv1 Grandmaster, or
when connected to an external PTPv1 Grandmaster.
1588v2
–
1
–
s
Sync interval when operating as a PTPv2 Grandmaster, or
when connected to an external PTPv2 Grandmaster.
TABLE 7
Differential ended audio inputs
PARAMETER
MIN.
TYP.
MAX.
UNITS
CONDITION/DETAILS
Inputs
–
–
2
–
Sampling rate
VOICE[1:0]
–
64
–
ksps