Curtiss-Wright | PG Drives Technology
SK77981-14
80 | R-net Technical Manual | Chapter 3 – Programming
7.10
EMERGENCY STOP SWITCH - (EMERGENCY STOP)
This sets whether an Emergency Stop Switch must be used when latched operation is programmed.
The programmable options are Yes and No.
If set to Yes, then a normally closed Emergency Stop Switch must be connected into the External Profile Switch Jack on the
Joystick Module, whenever latched drive or latched actuator operation is programmed. If such a switch is not fitted, then
operation of the wheelchair will be inhibited.
If set to No, then an Emergency Stop Switch is not required. This setting should only be used after a full assessment of the risks
involved, i.e. there is no way of effecting an emergency stop from latched drive or actuator operation.
WARNING:
Curtiss-Wright accepts no liability for losses of any kind resulting from the use of a wheelchair with latched drive or actuator
operation and with no normally closed Emergency Stop Switch fitted.
7.11
OBP KEYCODE ENTRY
This sets the method of entry into On-Board Programming (OBP).
The programmable options are Yes and No.
If set to Yes, then a sequence of button presses can be used to enter OBP. The sequence is as detailed at the end of this sec tion.
If set to No, then a hardware Dongle must be connected into the system in order to enter OBP.
OBP keycode entry is as follows:
With the system switched off, hold down the Horn button and then hold down the On/Off button until there is a short
bleep. Note, the normal power-up sound will occur prior to this bleep.
Release the Horn button, but continue to hold down the On/Off button until there are two further short bleeps.
Release the On/Off button, there will now be a longer bleep and OBP mode will be entered.
WARNING:
If this parameter is set to Yes, then it may be possible for a wheelchair user to gain entry to the OBP function. Curtiss-Wright
accepts no liability for losses of any kind if this method of OBP is set. Curtiss-Wright also accept no liability for losses of any
kind if OBP access is gained by unauthorised personnel obtaining a dongle.
7.12
POWER-UP MODE – (POWER UP MODE)
This sets the Mode that is selected when the system is powered-up.
The programmable options are in the form of a drop down, as shown in the following diagram.