Important Safeguards/Symbols

Models Included:

•   WB5GT63000
•   WB5GT30000
•   WB5GT19000

Service Manual – WB5GT Water Boiler

W

ilbur

 C

urtis

 C

o

., i

nC

.

This equipment is designed for commercial use. Any servicing other than cleaning and routine maintenance 

should be performed by an authorized Wilbur Curtis Company service technician.

•   DO NOT immerse the unit in water or any other liquid
•   To reduce the risk of fire or electric shock, DO NOT opens service panels. There are no user  service-

able parts inside. 

•   Keep hands and other items away from hot areas of the unit during operation.
•   Never clean with scouring powders or harsh chemicals.

CAUTION: 

DO NOT 

connect the unit to 

hot water supply. The 

inlet valve is not rated for hot 

water.

CAUTION: 

Follow 

this setup procedure 

before attempting 

to use this unit. Failure to 

follow these instructions can 

result in injury and/or void of 
warranty.

ISO 9001:2008 REGISTERED

WILBUR CURTIS CO., INC.

6913 Acco Street,

  Montebello, CA 90640-5403

For the latest information go to 

www.wilburcurtis.com

Tel: 800-421-6150

Fax: 323-837-2410

CAUTION: 

Equipment must be 

installed to comply 

with applicable federal, state, 

and local plumbing/electrical 

codes.

INSTALLATION

This Curtis unit is pre-set and ready to go from the factory. 
System Requirements:

  • Water Supply: 20 – 90 psi (minimum flow rate of 2.0 gpm)
  • Electrical: See electrical schematic.

3. Connect the unit to electrical outlet with appropriate amperage rating (See serial tag on machine).
4. Once power has been supplied to the unit, flip the toggle switch to the ‘ON’ position (located on the rear of 

the unit), the water tank will begin to fill. When the water level in the tank reaches the probe, the heating 

element will turn on. 

5. Water in the heating tank will require 60 to 70 minutes before reaching operating temperature (factory 

setting of 204°F).

NSF requires the following water connection:

1.  A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so 

that the unit can be moved for cleaning.

2.  This unit must be installed with adequate backflow protection to comply with applicable federal, 

state and local codes.

3.  Water pipe connections and fixtures directly connected to a portable water supply shall be sized, 

installed and maintained in accordance with federal, state, and local codes.

NOTE: A water filtration system must be used to help maintain trouble-free operation. Air must be 

purged from the cartridge prior to connection to equipment. In areas with extremely hard water, we 

highly recommend the use of a Curtis approved water filter. For our full line of filters, please log on to 

www.wilburcurtis.com.

SETUP STEPS

1.  The unit should be level (left to right - front to back), on a secure surface.  
2.  Connect the water line to the water inlet fitting on the rear of the unit. Wa-

ter volume going to the machine should be consistent. Use tubing sized 

sufficiently to provide a minimum flow rate of two gallons per minute.

1

For the latest specifications and information go to www.wilburcurtis.com

Technical support: 1-800-995-0417 M-F 5:30 

a

.

m

. - 4:00 

p

.

m

. PST

Email: [email protected]

Symbols:

WARNING

/

CAUTION

 – To advise about conditions that my result in property damage, 

personal injury or death

IMPORTANT

 – Notes about proper operation

Sanitation requirements

WARNING: 

Use the

leveling legs to level 

the brewer only. Do 

not use them to adjust brewer 

height. Do not extend them 

higher than necessary.

Summary of Contents for WB5GT19000

Page 1: ...When the water level in the tank reaches the probe the heating element will turn on 5 Water in the heating tank will require 60 to 70 minutes before reaching operating temperature factory setting of 2...

Page 2: ...P button for 10 seconds The temperature reading will change to Celsius 2 Release the TEMP button The LED screen will display the temperature in degrees Celsius default is 96 C AERATOR The aerator pump...

Page 3: ...2 12 14 35 PARTS LIST ITEM N PART N DESCRIPTION 1 2 3 4 5 5A 6 6A WC 58117 WC 5661 WC 43067a WC 2948 WC 102a b d WC 103c WC 847a b d WC 883c COVER TOP ALPGT D500GT D60GT TLP TCTS CBS GEMSS LID ASSY TA...

Page 4: ...SOR TEMPERATURE TANK GUARD SHOCK HEATING ELEMENT FOR SINGLE HEATING ELEMENT GUARD SHOCK HTNG ELMNT DOUBLE GUARD SHOCK RESET THERMOSTAT WC 522 THERMOSTAT HI LIMIT HEATER CONTROL DPST 277V 40A COMPOUND...

Page 5: ...ELECTRICAL SCHEMATIC 120 220V SINGLE PHASE MODEL WB5GT63000 5...

Page 6: ...6 ELECTRICAL SCHEMATIC 220V SINGLE PHASE MODEL WB5GT30000...

Page 7: ...ELECTRICAL SCHEMATIC 220V THREE PHASE MODEL WB5GT19000 7...

Page 8: ...ponents prepare a mild solution of detergent and warm water CAUTION Do not use cleansers bleach liquids powders or any other substance containing chlorine These products promote corrosion and will pit...

Page 9: ...This page intentionally blank...

Page 10: ...with all local electrical mechanical and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply Th...