background image

F

IND

 

OUT

 

MORE

ON

 

THE

 

WEB

.

WILBURCURTIS.COM

SERVICE MANUAL – MODEL TLXG0201S000

W

ILBUR

 C

URTIS

 C

OMPANY

, I

NC

.

USING THE THERMOPRO SERVER

WARNING – THERMOPRO SERVERS MAY BE HEAVY WHEN FILLED. CARE MUST BE TAKEN 

WHEN TRANSPORTING TO AVOID DROPPING OR SPILLING.

Use only coffee or water in the insulated dispenser. Do not use the airpot to dispense any other beverage. 

Preheating the airpot is recommended.

1.  Place a clean and empty server centered under one of the brewcones of the ThermoPro brewer.

2.  Make sure the READY TO BREW indicator is lit.

3.  Fill brewcone with the correct measure of ground coffee.

4.  Press the desired brew button on the side of the brewer with the empty airpot. The ThermoPro airpot 

employs the Curtis Brew-Thru lid and it is not necessary to remove the top lid before brewing.

5.  Allow the brewcone to completely drip before removing airpot for remote service.

SERVICING AIRPOT/THERMOPRO SERVER

Completely clear the unit of any coffee by opening the faucet to drain over a sink. Unscrew and remove the lid 
and tube assembly. 

1.  REPLACING THE GAUGE GLASS

The gauge glass can be removed for maintenance or to replace if broken. 

1. Carefully take hold of the gauge glass guard and lift away the guard from the 

front of the unit. 

2. The sight glass guard contains two extra glass tubes for replacing a  broken 

gauge glass. These are held in slots designed into the guard that run the 

length of the guard (see fig. 1).

3. Once the gauge glass guard is removed, you will observe that the gauge 

glass is held by the black plastic elbow at the top. Pull back on the gauge 

glass tube while slightly lifting at the elbow (flexible silicone fitting at the elbow 

will allow you to tilt the gauge glass tube). Lift the gauge glass out from the 

top of the faucet.

4. The glass tube will come out with a small silicone seal attached, one on each 

end. You can pull these off for cleaning (take care to replace the silicone seal 

as it was removed, with the large opening sliding over the glass tube).

 2.  REMOVING THE BASE ASSEMBLY

    Remove the base assembly for faucet repair or to move the body of the unit  

  for placement on a remote serving stand.

1. Remove the wing nut at the centerline of the ThermoPro.

2. Pull tab, left side (fig. 2.).

3. Hold the handle and Twist ¼ turn to lift off of base. Before lifting off the unit, 

please notice the mark on the bottom right edge of the airpot marked, “ALIGN 

TO INSTALL”. This will assist in the assembly of the base and body of the unit.

3. REMOVING THE FAUCET

  To replace the faucet or the silicone elbow fitting for repair or cleaning:

1. Remove the base assembly as described above.

2. Remove the Liner Mounting Retainer at the bottom of the liner (held in place by 

a black plastic nut). There is a key slot in the stainless body of the unit that aligns 

with a pin on the liner retainer for assembly.

Reviews: