C500AP & C500APT
AIRPOT COFFEE BREWER

Service Manual

Carton Contents

Brewer, C500AP
Brew Cone, S/S
Fitting, Flare Elbow
Paper Filters
Service Manual

1
1
1

25

1

Qty

Item

C

®

®

Unpacking . . . . . . . . . .

Shipping List . . . . . . . . .

Rough-in Drawing . . . .

Start up . . . . . . . . . . . . .

Coffee Brewing . . . . .

Care & Maintenance

Troubleshooting . . . . . .

Wiring Diagram . . . . . .

Illustrated Parts List . . .

Warranty . . . . . . . . .

1

1

1

2

2

3

3

5

7

Back

Cover

Table of Contents

Throughout this service manual, whenever the airpot brewer model C500AP is mentioned,
this information is typical to both the C500AP and C500APT. All parts are common except
where noted.

-

Summary of Contents for C500AP

Page 1: ...aper Filters ServiceManual 1 1 1 25 1 Qty Item C Unpacking Shipping List Rough in Drawing Start up Coffee Brewing Care Maintenance Troubleshooting Wiring Diagram Illustrated Parts List Warranty 1 1 1...

Page 2: ...company C500AP Airpot Coffee Brewer UNPACKING 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 12345678901234567890123456789012123456789012345678901234567890121234567890123456 123456789...

Page 3: ...er line to the brewer using copper tubing with female flare fitting 3 Turn on water 4 With top cover removed locate the thermostat see illustration page 8 37 turn the thermostat shaft clockwise until...

Page 4: ...ank may occasionally require removing of lime build up The frequency is determined by local water conditions Daily Cleaning POSSIBLE CAUSE SOLUTION Make sure the brewer is receiving enough water press...

Page 5: ...ater continues to flow in valve is leaking clean or replace valve Pull wire off from probe terminal Touch the body of the heating tank with the end of this wire If water stops try cleaning the probe P...

Page 6: ...als 6 and A on the timer when it has been activated There should be 110 to 120V going to the dump valve If not then the timer is faulty Replace timer If the timer is functioning properly step 13 next...

Page 7: ...WIRING DIAGRAM 6...

Page 8: ...C500 AP Airpot Coffee Brewer ILLUSTRATED PARTS MAIN VIEW 7...

Page 9: ...ILLUSTRATED PARTS DETAIL BUBBLES D 19 18 C500 AP Airpot Coffee Brewer 8 B 59 59 60...

Page 10: ...T 1 GPM 120V 10W SCREW 4x3 8 PHIL PAN HEAD POWER CORD CORD GRIP FLARE ELBOW 1 4 x 3 8 SCREW 1 4 20x PHILLIPS PAN HEAD STAINLESS STEEL TIMER COVER TIMER COVER TOP THERMOSTAT HEATING TANK COMPLETE LESS...

Page 11: ...ER 52 53 54 55 56 57 59 60 63 SHOCK GUARD FOR HEATING ELEMENT WASHER 9 16 I D TEFLON ELEMENT HEATING 1 6KW 120V W JAM NUT SILICONE WASHERS CLIP THERMOSTATCAPILLARY PLUG TANK DRAIN PP RED INSULATION WR...

Page 12: ...e supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The...