FLOTON ST20 USER MANUAL
Sleep Apnea Breathing Therapy
Device
ENGLISH
Page 1: ...FLOTON ST20 USER MANUAL Sleep Apnea Breathing Therapy Device ENGLISH...
Page 2: ...INGS 8 LIABILTY 9 INTRODUCTION 10 INTENDED USE 10 CONTRAINDICATIONS 10 DESCRIPTION OF THE DEVICE AND HUMIDIFIER 11 FLOTON ST20 11 FRONT AND BACK VIEW 12 CONTROL PANEL 13 HUMIDIFIER 14 ACCESSORIES 15 A...
Page 3: ...PCV CPAP 20 RAMP AND AUTO DISPLAY 20 FUNCTIONS THE DEVICE 21 I SLOP SPEED OF RISING PRESSURE 21 E SENS SENSITIVITY OF EXPIRATION TRIGGERING 21 SPONTANEOUS MODE S MODE 21 TIMED MODE T MODE 21 CPAP MODE...
Page 4: ...SE 25 CHANGING FILTER 25 TROUBLESHOOTING 26 SERVICE 29 SPECIFICATIONS 29 DISPOSAL 30 QUALITY WARRANTY ERROR BOOKMARK NOT DEFINED ELECTRIC MAGNETIC INFORMATION 31 GUIDANCE AND MANUFACTURERS DECLARATION...
Page 5: ...Floton Auto CPAP 5 DISCLAIMER OF WARRANTY AND LIMITATION OF CURASA ERROR BOOKMARK NOT DEFINED CONTACT DETAILS 35...
Page 6: ...uments Manufacturer Date of manufacture Serial number Type B applied part Class II Double insulated The device accessories and the packaging have to be disposed correctly at the end of the usage Pleas...
Page 7: ...to the patient s airway Do not place the device near any items curtains bedding couch or heating devices air conditioners radiators vents that may disrupt the airflow around the device Before carryin...
Page 8: ...op using it immediately contact an authorized dealer The device can only be switched off completely when the power supply is disconnected from the wall socket Make sure the exhalation opening in the m...
Page 9: ...eding the level of 3V m in the test conditions of EN 60601 1 2 The operation of high frequency diathermy equipment Defibrillators or short wave therapy equipment Radiation e g X ray CT Magnetic fields...
Page 10: ...e and airway dryness increasing the comfort for the patient The therapeutic pressure is prescribed by a physician according to patient s condition CONTRAINDICATIONS The use of positive airway pressure...
Page 11: ...11 Sleep Apnea Breathing Therapy Device User Manual 11 DESCRIPTION OF THE DEVICE AND HUMIDIFIER FLOTON ST20...
Page 12: ...Equipment connected to the analog or digital interfaces must comply with the respective IEC standards e g IEC 950 for data processing equipment and IEC 60601 1 for medical equipment All configuration...
Page 13: ...13 Sleep Apnea Breathing Therapy Device User Manual 13 CONTROL PANEL...
Page 14: ...athing Therapy Device User Manual 14 HUMIDIFIER Warning The humidifiers DC power jack can only be used to connect to the device with the provided power cable for the humidifier Do not connect it with...
Page 15: ...rd and power supply adapter Connecting tube Hose with a pressure tube WARNING The device should be used only with the external AC DC adapter provided by manufacturer Use of other AC DC adapters may ca...
Page 16: ...amaged and if any accessories or parts are missing Put the device on a stable and even surface Make sure the air inlet in the back of the device is not blocked Connect the power supply adapter with th...
Page 17: ...o other additions and be below the maximum water line The temperature range of the humidifier can be adjusted according to patient s requirement When humidifier is connected correctly and the device i...
Page 18: ...mH2O per step VT Tidal Volume N A BPM Breaths per minute 5 to 40 1bpm per step Leak Leakage Volume per minute N A I SLOP Speed of rising pressure 1 to 6 1 per step E SENS Sensitivity of expiration tri...
Page 19: ...will be continuously on when the device is in stand by mode Device On Off means that motor is On or Off Power On Off means that power supply is On or Off INPUT KEYS Input keys are used for selecting f...
Page 20: ...ISPLAY ST T S APCV CPAP RAMP AND AUTO DISPLAY Warning IPAP cannot be set lower than EPAP When CPAP is enabled then IPAP and EPAP are limited to 20cmH2O Warning High EPAP pressure could cause discomfor...
Page 21: ...tion triggering If E_SENS is 1 the expiration triggering is most sensitive SPONTANEOUS MODE S MODE The inspiration and expiration phase is dependent on patient s spontaneous breathing During the inspi...
Page 22: ...NTROL MODE APCV ASSISTED PRESSURE CONTROL VENTILATION APCV mode is similar to the ST mode except that all breaths in a controlled cycle The APCV mode is a pressure limited device or patient triggered...
Page 23: ...sound to inform the patient that they should remove the mask The alarm can be switched off by pressing the on off key or will switch off automatically if power resumes CHECKING THE POWER FAILURE ALAR...
Page 24: ...To clean the exterior of the device use a dampened cloth and a mild detergent Allow the device to dry completely before plugging in the power cord 2 The mask and tubing should be cleaned daily For de...
Page 25: ...er is in the filter cassette at the back of the device Take it out and change it with a new one every week Never use the device without a filter Dirty inlet filters may cause high operating temperatur...
Page 26: ...x Breathing through mouth Use chin strap or full face mask Low therapeutic pressure ask your physician Irritated or dry eyes Leakage between mask and skin Adjust the mask s position and headgear If th...
Page 27: ...for effective therapy You may take up to 4 weeks to be accustomed to higher pressures When using the device breathe through nose with mouth closed and keep calm If you continue to experience discomfo...
Page 28: ...ice center Motor works normally but the output pressure is lower than the set pressure Patient hose or pressure tube is not correctly connected with the device Air leakage through mask or patient tube...
Page 29: ...variance 0 4 cm H2O 0 04kPa Ramp time 0 60min adjustable 1min step Noise 10 cm H2O 1 0kPa 30dB A Dimensions 170 mm L 117 mmW 93 mmH Weight 1 6Kg 1 4Kg without humidifier Water temperature 44 C Maximum...
Page 30: ...C Relative humidity 10 93 non condensing Atmosphere pressure 700hPa 1060hPa Transport or storage Temperature 20 C 55 C Relative humidity 10 93 non condensing Atmosphere pressure 500hPa 1060hPa DISPOS...
Page 31: ...at it is used in such an environment Emission test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The Floton ST20uses RF energy only for its internal function Therefore...
Page 32: ...l environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for...
Page 33: ...ance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These g...
Page 34: ...mitter W Separation distance according to the frequency of transmitter m 150 kHz to 80 MHz P V d 1 5 3 80 MHz to 800 MHz P E d 1 5 3 800 MHz to 2 5 GHz P E d 1 7 0 01 0 12 0 12 0 23 0 1 0 39 0 37 0 74...
Page 35: ...Apnea Breathing Therapy Device User Manual 35 CONTACT DETAILS Curative Medical Devices GmbH Manufacturer address Blasewitzer Str 41 01307 Dresden Germany Tel 49 351 4504500 Fax 49 351 4504511 info cur...