Safety instructions

•  read this guide carefully before installing the 

appliance, and keep it with care in an accessible 
place for any future consultation by the various 
operators.

• Moreover, the manual must always accompany 

the product through its life, even in case of 
transfer.

• Before any movement or installation, check 

that the room is suitable and systems comply 
with the installation country standards and the 
specifications indicated on the appliance rating 
plate.

• all installation, assembly and non-routine 

maintenance operations must be performed 
exclusively by qualified technicians that are 
authorised by the Dealer, in compliance with the 
regulations in force in the user country, and with 
the regulations on systems and work safety.

• Before performing any installation or 

maintenance, disconnect the electricity supply.

• unauthorised actions, tampering or 

modifications that do not follow the information 
provided in this manual can cause damages, 
injuries or fatal accidents and null and void the 
warranty.

• It is forbidden to install the hood in environments 

at risk of explosion.

• Installation or maintenance that fails to comply 

with the instructions in this manual may cause 
damage, injury or fatal accidents.

• Persons not involved with the appliance 

installation may not pass through or stand in the 

work area during appliance assembly.

• The serial plate provides important technical 

information. This is vital in case of a request for 
maintenance or repair of the equipment: please 
do not remove, damage or modify it.

• failure to follow these regulations may cause 

damage or even fatal injury, subsequently 
invalidating the guarantee and relieving the 
Manufacturer of all liability.

The company cannot be held liable for any print or transcription 
errors, reserving the right to make changes where deemed 
suitable without prior notice. 
Partial reproduction without the Manufacturer's consent 
is prohibited. Measurements are purely indicative and not 
binding. 
The original language used to prepare this manual is english: 
the Manufacturer is not responsible for any translation/
interpretation or print errors.

Symbols used in the manual and on 

the labels applied to the machine

Indicates that caution is required when performing 
an operation described in a paragraph that bears this 
symbol. The symbol also indicates that maximum 
operator awareness is required in order to avoid 
unwanted or dangerous consequences

reference to another chapter where the subject is 
dealt with in more detail.

Manufacturer’s tip

Indicates that the surfaces marked with this symbol 
may be hot and must therefore be touched carefully

Dangerous voltage

The symbol identifies the terminals which, connect-
ed to each other, carry the various parts of a device 
or system to the same potential (not necessarily the 
earth potential)

Indicates that it is necessary to read carefully the 
paragraph marked with this symbol before installing, 
using and maintaining the equipment

3

 INsTaLLaTION

Summary of Contents for Donatello KDN 435

Page 1: ...Donatello HOOD Pre installation and installation manual KDN 435 KDN 635 KDN 635L KDN 935 ...

Page 2: ...ical data hood triple oven 13 Donatello KDN 635L hood technical data hood single oven 14 Donatello KDN 635L hood technical data hood double oven 15 Donatello KDN 635L hood technical data hood triple oven 16 Donatello KDN 935 hood technical data hood single oven 17 Donatello KDN 935 hood technical data hood double oven 18 Donatello KDN 935 hood technical data hood triple oven 19 3 INSTALLATION 20 S...

Page 3: ...tion complies with the current regulations on health and safety and systems in the workplace is protected from the weather has a maximum temperature of between 5 41 F and 35 C 95 F has a maximum humidity of 70 between the hood and the ceiling there is a distance of about 600 mm 24 in shorter distances could damage ceilings made of particularly delicate and heat sensitive materials e g wood there i...

Page 4: ...aust system can be installed in neutral versions Fig 3 The following must be installed during installation the pipe A supplied by the Manufacturer the connection B supplied by the Manufacturer a flue D blocking it with a metallic clamp C NEITHER supplied by the Manufacturer The flue must be exclusively used by the equipment have a 150 mm diameter Ø5 91 in to guarantee correct draught up to a maxim...

Page 5: ... for single phase cabling Installed cable section 3x1 mm2 silicone cable Maximum capacity m3 h 700 DN 935 Units of measurement DN935NT neutral KDN935AS with extraction fan Electrical supply 50 60 Hz Volt AC 230 Maximum absorption kW max 0 13 Connection cable n x mm2 Installed cable type H07RN F three pole cable for single phase cabling Installed cable section 3x1 mm2 silicone cable Maximum capacit...

Page 6: ... B C A D E A Oven supply input B Circuit breaker only for American market C Equipotential D Hood supply input E Oven smoke exhaust F Hood fume inlet conduit G Extraction fan Key Donatello hood technical data ...

Page 7: ... 0 1 2 0 0 qv m3 h qv m3 h P W psf Pa psf mmcda Donatello hood technical data Fan technical data Characteristic curves acoustic features qv flow in m3 h psf Static pressure in mmcda and Pa P Incoming power in W SFP Specific power factor in W m3 s blue curves Compliance data with ISO 5810 Sound pressure level dB A Extraction Expulsion Radiated 59 56 42 Sound pressure level measured in free field at...

Page 8: ...8 Donatello KDN 435 hood technical data hood single oven ...

Page 9: ...9 Ed 0221 70702730 REV03 Donatello hood Pre installation Installation Donatello KDN 435 hood technical data hood double oven ...

Page 10: ...10 Donatello KDN 435 hood technical data hood triple oven ...

Page 11: ...11 Ed 0221 70702730 REV03 Donatello hood Pre installation Installation Donatello KDN 635 hood technical data hood single oven ...

Page 12: ...12 Donatello KDN 635 hood technical data hood double oven ...

Page 13: ...13 Ed 0221 70702730 REV03 Donatello hood Pre installation Installation Donatello KDN 635 hood technical data hood triple oven ...

Page 14: ...14 Donatello KDN 635L hood technical data hood single oven ...

Page 15: ...15 Ed 0221 70702730 REV03 Donatello hood Pre installation Installation Donatello KDN 635L hood technical data hood double oven ...

Page 16: ...16 Donatello KDN 635L hood technical data hood triple oven ...

Page 17: ...17 Ed 0221 70702730 REV03 Donatello hood Pre installation Installation Donatello KDN 935 hood technical data hood single oven ...

Page 18: ...18 Donatello KDN 935 hood technical data hood double oven ...

Page 19: ...19 Ed 0221 70702730 REV03 Donatello hood Pre installation Installation Donatello KDN 935 hood technical data hood triple oven ...

Page 20: ...nical information This is vital in case of a request for maintenance or repair of the equipment please do not remove damage or modify it Failure to follow these regulations may cause damage or even fatal injury subsequently invalidating the guarantee and relieving the Manufacturer of all liability The company cannot be held liable for any print or transcription errors reserving the right to make c...

Page 21: ...any corrosive or abrasive products or sharp or pointed instruments Check that all the parts making up the hood are in good condition and without any faults or breakages if that is not the case contact the Dealer for the procedures to follow Serial number plate reading Fig 6 The serial number is on the back of the appliance It provides important technical information that is vital in case of a requ...

Page 22: ...sitioned only over a Donatello oven Fig 7 Disconnect the power supply from the oven to which the hood will be connected Fix the hood to the oven below acting as shown in the figure Make sure that between the hood and the ceiling there is a dis tance of about 600 mm 24 in shorter distances could dam age ceilings made of particularly delicate and heat sensitive materials e g wood Fig 8 Open the side...

Page 23: ...is connected to comply with the current regulations in the country of use Pass the hood cable with the connector K through the hole you took the cap off previously T Block the cable with the locknut D Plug the hood connector K into the socket P in the oven electrical panel If required the cable can be replaced by the Dealer or its technical service or by a person with similar qualifica tions to pr...

Page 24: ... Motor start capacitor CTRL Speed variation board Installed cable type H07RN F three pole cable for single phase cabling Installed cable section 3x1 mm2 silicone cable Suction hood Wiring diagrams brown blue brown blue black yellow green yellow green blue brown ...

Page 25: ...aust system can be installed in neutral versions Fig 10 The pipe A and connection B both supplied by the Manufacturer must be installed during installation Fig 11 It is then necessary to install a flue D blocking it with a metal clamp C neither is supplied by the Manufacturer The flue D must be exclusively used by the equipment have a 150 mm diameter Ø5 91 in to guarantee correct draught up to a m...

Page 26: ...rect Checking the operation Start the appliance following the instructions in the Use and Maintenance manual monitor it during the whole test and check that all the electrical components work properly Finish off explaining to the user how to use the appliance in an optimal and safe way and how to carry out ordinary mainte nance and cleaning Positioning checks Reference chapter on page Has the prot...

Page 27: ...27 Ed 0221 70702730 REV03 Donatello hood Pre installation Installation Notes ...

Page 28: ...CUPPONE 1963 Cuppone F lli S r l Via Sile 36 31057 Silea TV ITALY T 39 0422 361143 F 39 0422 360993 info cuppone com www cuppone com ...

Reviews: