To set individual sensitivity levels for UV, Fluorescence and Magnetics, press and hold down
SD
for 2-3 seconds. Press
KEY 4
to set sensitivity settings to
LOW
,
MED
or
HI
for COUNT
mode. In VALUE mode, each denomination ($1-$100) may be set independently to
LOW
,
MED
or
HI
. The
SPEED key
(
KEY 5
) is used to make a sub-selection and move the arrow prompt.
KEY 6
is used to set the option. In VALUE mode for each level (
LOW
,
MED
or
HI
) of each
denomination, the user has the option to set sensitivity from
1-10
or
OFF
.
The appropriate level of sensitivity will depend on the condition of the currency and the
counterfeit note frequency.
Thickness Adjustment Dial
This gray dial is located on top of the JetCount. The dial adjusts the tightness of the feeder in
which the notes pass through during JetCount operation. To make adjustments, turn the dial to
the right or left. If the machine is experiencing consistent chains or doubles, adjust the dial to
allow notes to pass through the JetCount without error.
Operating Modes
JetCount provides two basic operating modes for processing documents: COUNT
PROCESSING (COUNT) and CURRENCY PROCESSING (VALUE). Processing speed is
programmable for 600-1,600 documents per minute in both modes.
Mode
Description
COUNT PROCESSING
(COUNT)
Counts any currency, food stamps, coupons, etc., that fit the hopper and paper
size specifications. In this mode, JetCount is only counting “slips of paper” (no
currency scanning is taking place).
CURRENCY
PROCESSING
(VALUE)
When in the VALUE mode, the DENOM key or Direct Access Denomination keys
permit setting the JetCount so that each note passing through the machine is
counted as if it were a specific value of currency. JetCount may be set to count
each note as $1, $2, $5, $10 $20, $50 or $100.
Choosing a Mode of Operation
The machine is shipped with COUNT mode enabled. If the machine is equipped with VALUE
mode and
Direct Access keys
, press
VALUE
(
KEY 15
) to toggle between COUNT (Count
Processing) or VALUE (Currency Processing). In VALUE mode, you must select the value of
the denomination you are processing through the machine. JetCount will apply this value
The lower the sensitivity level, the greater the opportunity to pass a counterfeit
note. The higher the sensitivity level, the greater the opportunity to stop on a good
(non-counterfeit) note.
By turning the thickness adjustment dial to the right, the rollers are made tighter.
By turning the thickness adjustment dial to the left, the rollers are made looser,
thereby allowing notes to flow through the JetCount easier.