2. General Information
1. Installation must conform with local, state, and national codes, or in the absence
of local codes, with the Standard for the Storage and Handling of Liquefied
Petroleum Gases, in accordance with ANSI/NFPA 58 and/or the National Fuel
Gas Code, ANSI Z223.1, as applicable.
2. Follow safety, maintenance, and test firing instructions packaged with Heater.
3. Refer to model specifications label for gas type (LP or Natural Gas).
4. Check all connections for gas leaks.
5. Gas supply and regulator must be installed outside building.
6. The hose assembly should be protected from traffic, building materials, and any
contact with hot surfaces both during and while in storage.
7. Do not open heater doors, or remove a heater panel, or move or handle the
heater while it is operating, hot, or connected to power supply.
8. Turn power OFF before servicing. (Heater may start at any time if power is
connected.)
9. Heater is not recommended for heating human living quarters.
10. Not to be used for heating where flammable liquids and vapors are stored or
used.
11. Inadequate gas volume and (or) pressure will directly influence the combustion
efficiency of the heater. Adequate gas volume and (or) pressure is the
responsibility of the installer.
12. Adequate ventilation is required.
13. Combustion and ventilation air must not be obstructed.
14. Not for use with duct work other than types provided by manufacturer.
15. Position heater properly before use. Heater must be level and in accordance with
minimum clearances.
16. For safety, this heater is equipped with air flow proving switch and manual reset
high limit switch.
17. Keep temperature of fuel containers below 100°F (37.8°C). Containers must be
installed outside building.
18. Heater must not be operated for one hour following wash-down.