10. Display Unit Calibration and Setup
Full Bin Calibration
1. Once an empty bin calibration has been
performed, a full bin calibration must be
performed after filling the bin the first time.
This procedure can also be done more than
once, but should only be necessary the first
time. A full calibration will not be allowed if
the feed is not added.
NOTE: This load cell technology is a patented
calibration, and calibration is not actually
complete until a bin has cycled through its
contents one complete time.
2. Fill the bin to as close to the maximum weight
as practical. The unit will interpret to above
the full bin calibration if the weight of feed
added at a later time is more than at the time
of calibration. The display unit will interpolate
up to twice the full bin calibration weight. If
the weight is more than this, then a
“Perform FullBin” message will be displayed.
3. Press the CAL button from the normal
display mode. “FullBin: lb nnnnn” will display.
Use the UP/DOWN arrow buttons to select
each digit. Pressing the ENTER button will
select that digit and the cursor will scroll to
the next position. After ENTER has been
pressed for the last digit, the unit will return
to the normal display and the weight entered
will be displayed.
4.
Please note that to abort this operation,
pressing the CAL button will leave this mode
and return to the normal display.
5. Possible error messages:
(See Troubleshooting Section on Page 52.)
a. “Perform: FullBin”
b. “FullBin: Add Feed”
c. “FullBin: Dec Feed”
d. “FullBin: Do Empty”
e. “FullBin: No Cells”
f. “Perform Empty”
Figure 10G Load Cell Error (Cell 4)
Figure 10H Load Cell Error (Cell 4)