![Cumberland AP Cumberland EDGE Installation Manual Download Page 29](http://html1.mh-extra.com/html/cumberland/ap-cumberland-edge/ap-cumberland-edge_installation-manual_2698006029.webp)
Figure 4-1
Maintenance Parts
Replacing the Humidity Sensor
Information supplied by AIRMAR Technology Corp.
What You Should Know
The humidity sensor has an average life expectancy of 5-6 years according to the EDGE 110WX Weather
Station environment. After 5-6 years, replace it with another sensor by following the steps below.
1. Remove the two screws from the humidity sensor or blank.
2. Remove the sensor or blank.
3. Push the new humidity sensor into place and fasten it with the two screws supplied. Using a torque
wrench, apply 0.25 - 0.30Nm.
CAUTION
Do not over-tighten.
PNEG-2248
Weather Station