IMPORTANT:
The communication network must be installed in a daisy chain topology. Consult the
wiring diagrams to see the maximum cable distance according to the wire gauge.
IMPORTANT:
The recommended installation wire gauge is 18 AWG (diameter of 1.02mm or cross
sectional area of 0.82mm
2
) when using communication wires at a length of 4000 feet
(1200 meters). The cable must be twisted pair and shielded.
WARNING
Installation must only be performed by qualified service personnel.
NOTICE
When tightening small terminal blocks, use a torque between 4.43lbf*in
(0.5N*m) and 5.2lbf*in (0.6 N*m) to fasten a wire gauge from 16AWG (diameter of
1.29mm or cross sectional area of 1.30mm
2
) to 18AWG (diameter of 1.02mm or
cross sectional area of 0.82mm
2
).
The communication network must be installed in a daisy chain topology. The order of the wires is
very important. At both ends of network, the End-of-Line must be activated. If the wiring can’t be
done in a single chain, you might need to deactivate the end-of-line (EOL) resistor to improve com-
munication. AP/Cumberland does not warranty the proper operation if the topology network is not
daisy chain.
Figure 3-1
Daisy Chain Topology
Connecting a loadcell
There is a possibility to connect up to 8 loadcells with to EDGE
Bin Scale 3 Wires LC
. A 5V voltage refer-
ence of 200mA maximum is available for all outputs SIG+ (LC(x) - SIG+). The outputs LC(x) – SIG+ are
the excitation voltage for the loadcell. The signal SIG- is the feedback of the loadcell.
NOTE:
A minimum wire gage of 24 AWG (diameter of 0.51mm or cross sectional area of 0.20mm
2
) is
required for a proper operating. The maximum cable length allowed (including cable extensions)
is 50ft. (15m). The cable must be twisted and shielded.
30
891–00577
EDGE Bin Scale 3 Wires LC
Summary of Contents for 074-11772
Page 26: ...NOTES 26 891 00577 EDGE Bin Scale 3 Wires LC...
Page 34: ...Chapter 3 Basic connections Figure 3 3 Loadcell Wiring 34 891 00577 EDGE Bin Scale 3 Wires LC...
Page 38: ...NOTES 38 891 00577 EDGE Bin Scale 3 Wires LC...
Page 48: ...Chapter 6 Setup Figure 6 2 Tank group setup screen 48 891 00577 EDGE Bin Scale 3 Wires LC...
Page 59: ...891 00577 EDGE Bin Scale 3 Wires LC 59...
Page 64: ...NOTES 64 891 00577 EDGE Bin Scale 3 Wires LC...
Page 66: ...NOTES 66 891 00577 EDGE Bin Scale 3 Wires LC...
Page 68: ...NOTES 68 891 00577 EDGE Bin Scale 3 Wires LC...
Page 78: ...NOTES 78 891 00577 EDGE Bin Scale 3 Wires LC...
Page 80: ...NOTES 80 891 00577 EDGE Bin Scale 3 Wires LC...
Page 82: ...NOTES 82 891 00577 EDGE Bin Scale 3 Wires LC...
Page 84: ...NOTES 84 891 00577 EDGE Bin Scale 3 Wires LC...
Page 88: ...NOTES 88 891 00577 EDGE Bin Scale 3 Wires LC...
Page 90: ...NOTES 90 891 00577 EDGE Bin Scale 3 Wires LC...
Page 94: ...NOTES 94 891 00577 EDGE Bin Scale 3 Wires LC...
Page 100: ...NOTES 100 891 00577 EDGE Bin Scale 3 Wires LC...