Regeneration Flow Diagrams
53
Cat. No. 01024000
Acid Draw
Backwash Inlet (C1), Backwash Outlet (C4) valves and the Cation valve (C2) are now closed. Flow through the pressure
regulator directs water to the top of the tank. The acid chemical pump is activated and acid from the chemical container is
fed at connection CP. The mixture of acid and water (normally 6 percent) is directed to the top of the resin bed. The Acid
flows down through the bed removing the Cations collected during Service Cycle. The excess acid and the waste cations
exit the Cation Column and flow through to Drain (C3). This drain water is acidic (low pH) and must be neutralized prior to
sending it to the city sewage system
C1
C4
A5
C2
A3
A1
A2
A4
C3
A6
C5
CP
AP
PR
2
ACID
PUMP
ON
ACID
SUPPLY
TO
NEUTRALIZATION
TANK
HYDROCHLORIC
ACID
Figure 17.
Acid draw cycle.
The percentage of the acid can be adjusted with use of the adjustment knobs on the air regulating valve (see
bottom of the tank. The specific gravity of the solution is used to determine the percentage of acid. Refer to the specific
gravity chart contained in the
"Appendix B Regeneration Specifications" on page 77
.