Quality of Water (Conductivity or Resistivity)
Ions in the water conduct electricity. Electric current flows easier with high concentrations of ions than it does with low
concentrations. High quality water is low in ion concentration therefore, has a high resistance to electric current. The mea-
surement of electrical conductivity or resistivity provides an accurate measurement of ionic concentration in the water.
Sodium Chloride
(mg/l)
TDS, mg/l
(as CaCO
3
)
Conductivity
(µS/cm)
Resistivity
(ohms)
TDS, grains/gal
(as CaCO
3
)
0.024
0.020
0.050
20,000,000
0.0011
0.026
0.022
0.055
18,000,000
0.0012
0.033
0.028
0.07
14,000,000
0.0016
0.039
0.033
0.08
12,000,000
0.0019
0.047
0.04
0.1
10,000,000
0.0023
0.094
0.08
0.2
5,000,000
0.0047
0.235
0.20
0.5
2,000,000
0.0116
0.47
0.40
1.0
1,000,000
0.0233
0.63
0.53
1.3
750,000
0.030
0.94
0.8
2
500,000
0.046
2.35
2.0
5
200,000
0.117
4.70
4.0
10
100,000
0.234
9.41
8.0
20
50,000
0.467
23.5
20
50
20,000
1.17
47.0
40
100
10,000
2.34
94.1
80
200
5,000
4.68
470
400
1,000
1,000
23.4
941
800
2,000
500
46.8
= Typical performance range for two-bed deionizer