M1 Series Specifications
3
Cat. No. 01022940
M1 Series Specifications
NOTE Specifications for M1 RO 230V (international) are in
“M1 RO International Specifications” on page 60
1S
2S
3S
4S
2L
3L
4L
1F
2F
Nominal Capacity, GPD [m³/hr]*
250
[0.04]
500
[0.08]
750
[0.12]
1000
[0.16]
1200
[0.19]
1700
[0.27]
2200
[0.35]
2000
[0.32]
4000
[0.63]
Dimensional, Series M1 Units
Width - in [mm]
34.5 [876]
38.5
[978]
34.5 [876]
38.5
[978]
34.5 [876]
Depth - in [mm]
8.7 [221]
Height - in [mm]
34.8 [884]
45.5 [1156]
Operating Weight, lb [kg]
77 [35]
81 [37]
92 [42]
96 [44]
88 [40]
103 [47]
111 [50]
97 [44]
129 [59]
Unit Connections
Inlet (Tube) - in
1/2"
Product (Tube) - in
1/2"
Concentrate (Tube) - in
3/8"
Electrical
Motor Horsepower, hp [kW]
0.333 [0.25]
0.75 [0.56]
Power Requirement (VAC/phase/Hz)
115/1/60
Full Load Current, amp (@115V)
8
12
Hydraulic - Prefilter
Housing Quantity
1
Cartridge Rating, micron
5
Cartridge Length - in [mm]
10 [254]
Hydraulic - RO
RO Housing Quantity
1
2
3
4
2
3
4
1
2
RO Element Quantity
1
2
3
4
2
3
4
1
2
RO Element Size - in [mm]
2.5x21 [63.5x533.4]
2.5x40 [63.5x1016]
4x40 [101.6x1016]
RO Array
1
1:1
1:1:1
1:1:1:1
1:1
1:1:1
1:1:1:1
1
1:1
Product Flow - gpm [L/min]*
0.17
[0.64]
0.35
[1.32]
0.52
[1.97]
0.69
[2.61]
0.83
[3.14]
1.18
[4.47]
1.53
[5.79]
1.40
[5.30]
2.8
[10.6]
Concentrate Flow - gpm [L/min]*
0.51
[1.93]
0.35
[1.32]
0.52
[1.97]
0.69
[2.61]
0.83
[3.14]
1.18
[4.47]
1.53
[5.79]
4.17
[15.78]
2.78
[10.52]
Required Inlet Feed Flow - gpm [L/
min]
0.68
[2.57]
0.7
[2.65]
1.04
[3.94]
1.38
[5.22]
1.66
[6.28]
2.36
[8.93]
3.06
[11.58]
5.56
[21.04]
5.56
[21.04]
Pump Flow @ 150 psi, gpm [L/min]
1.6 [6.06]
2.7 [10.44]
3.1
[11.73]
5.6 [21.2]
Maximum Module Feed Pressure psig
[kPa]
150 [1034]
Nominal Module Feed Pressure psig
[kPa]
†
95
[654.6]
100
[689]
103
[709.7]
104
[716.6]
96
[661.4]
97
[668.3]
101
[695.9]
95
[654.6]
101
[695.9]
Max. Product Pressure psig [kPa]
40 [275.6]
Inlet Pressure Min., dynamic psig [kPa]
20 [137.8]
Maximum, dynamic psig [kPa]
50 [344.5]
Operating Temp °F [°C]
33-100 [1-38]
Recovery (%)*
Design
25
50
50
50
50
50
50
25
50
Minimum
15
15
40
40
40
40
40
15
40
Salt Rejection, Nominal (%)
98
†Calculated using a 0.85 fouling factor
*Nominal capacity based on new RO membranes operating on a properly pretreated feed water of 500 ppm TDS as NaCl,
77 °F (25 °C), Silt Density Index (SDI) below 3, and supplying water to atmosphere. Productivity will vary depending on
the actual feed water quality and temperature. See
“Feed Water Limits” on page 77
.
Summary of Contents for M1 Series