background image

Welcome To Your New World of Better Living with Culligan Water.

Congratulations on selecting the Aquasential

®

 RO and Smart RO Advanced Drinking Water Systems� With Culligan’s 

many years of knowledge and experience in water treatment, you can be confident that the model you selected has been 

designed and engineered to provide years of service with a minimum of care and attention�
If this is your first experience having filtered, conditioned water in your home, you’ll love the amazing difference it makes� 

We promise that you’ll never want to be without it again�
The Culligan

®

 Aquasential

®

 RO and Smart RO Advanced Drinking Water Systems are designed to meet the needs of 

applications for high quality water� This manual contains important information about the units, including information 

needed for operating and maintenance procedures�
This manual is based on information available at the time it was finalized, approved, and published� Continuing design 

refinement could cause changes that may not be included in this publication�
Your local independently operated Culligan dealer employs trained service and maintenance personnel who are 

experienced in the installation, function and repair of Culligan equipment� This publication is written specifically for these 

individuals and is intended for their use�
The Aquasential® RO and Smart RO Advanced Drinking Water Systems utilize a high capacity reverse osmosis 

membrane which uses a tightly woven membrane that acts as a barrier to substances� Water is pushed up against this 

membrane at pressure� Depending on the weave of the membrane only a certain percentage of substances can pass 

through� These systems’ high capacity membrane can reduce up to 95% of substances�
The Aquasential

®

 RO and Smart RO Advanced 

Drinking Water Systems are tested and certified 

by WQA to NSF/ANSI 58, NSF/ANSI 42, NSF/

ANSI 53, NSF/ANSI 401, NSF/ANSI 372, CSA 

B483�1 and NSF Protocol P231 and conform to 

these standards for specific performance claims 

as verified and substantiated by test data� See 

performance data sheet included in this manual  

for specific claims�
Model: ESP32-WROOM-32D used in Aquasential Smart RO� 

Contains FCC ID: 2AC7Z-ESPWROOM32D and IC: 21098-ESPWROOM32D�
This device complies with part 15 of the FCC Rules subject to the following two conditions: (1) This device may not cause harmful 

interference (2) This device must accept all interference received including interference that may cause undesired operation�
Le présent appareil est conforme aux CNR Innovation, Sciences et Développement économique Canada applicables aux 

appareils radio exempts de licence� L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil nedoit pas 

produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est 

susceptible d’en compromettre le fonctionnement�
This device complies with Health Canada’s Safety Code� The installer of this device should ensure that RF radiation is not 

emitted in excess of the Health Canada’s requirement�
Cet appareil est conforme avec Santé Canada Code de sécurité 6� Le programme d’installation de cet appareil doit s’assurer 

que les rayonnements RF n’est pas émis au-delà de I’exigence de Santé Canada�
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to 

operate the equipment�
Les changements ou modifications non expressément approuvés par la partie responsable de la conformité pourraient annuler 

l’autorité de l’utilisateur à utiliser cet équipement�
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC 

Rules� These limits are designed to provide reasonable protection against harmful interference in a residential installation� 

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications� However, there is no guarantee that interference will not 

7

01040605  A  06/21

Thank You!

Summary of Contents for Aquasential RO

Page 1: ...Aquasential RO and Smart RO Advanced Drinking Water Systems Models from 2021 DCO 210105 06 03 21 CAT 01040605 Rev A 2021 Culligan International Company...

Page 2: ...Analytical Laboratory is certified to perform coliform and E coli testing We strive to provide our customers with the testing they need at the lowest possible cost with the quickest turn around time S...

Page 3: ...Customer 5 Thank You 7 Specifications 9 Application Operation 11 Navigation 14 Things to Check Before You Call 16 Care Cleaning 17 Performance Data Sheet 18 Records Data 32 Culligan Limited Warranty 3...

Page 4: ...paragraphs are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and careful attention are conditions which cannot be built into...

Page 5: ...und fault circuit interrupter GFCI GROUNDING INSTRUCTIONS This appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a pat...

Page 6: ...is 25 2 C The full battery charging cycle 6 0V to 8 4V takes approximately 8 5 hours As a safety precaution charging terminates after 11 25 hours To start charging plug the 12V power supply in the fro...

Page 7: ...for specific performance claims as verified and substantiated by test data See performance data sheet included in this manual for specific claims Model ESP32 WROOM 32D used in Aquasential Smart RO Con...

Page 8: ...ion Sciences et D veloppement conomique Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouil...

Page 9: ...er than 10 gpg will reduce the life of the membrane The Arsenic cartridge must be installed after the RO membrane All specialty cartridges must have a Performance Indicator Device PID installed to tra...

Page 10: ...eral TD Min 1 1 year or 1 000 gallons TD Min 2 2 year or 2 000 gallons Specialty Remineralization Min 1 1 year or 1 000 gallons Min 2 2 year or 2 000 gallons Specialty Arsenic AS3 1 1 year or 1 000 ga...

Page 11: ...te Total Dissolved Solids The minimum driving force which is necessary to stop or reverse the natural osmosis process is termed osmotic pressure As the total dissolved solids level of the feed water i...

Page 12: ...e only a certain percentage of contaminants can pass through Reverse Osmosis can reduce up to 99 of contaminants Advanced Filtration The advanced filtration cartridges are specifically designed to red...

Page 13: ...h lab For more information please contact your local Culligan dealer Additional information about the arsenic in water can be found through the EPA s website at www epa gov There are two forms of arse...

Page 14: ...ed Wi Fi blinks during Bluetooth pairing Blue blink Wi Fi blinks during Wi Fi pairing Green blink Wi Fi when Wi Fi connection lost Red blink LED Indicators on the RO unit 1 Year Filter 2 Year Filter I...

Page 15: ...is in use Figure 2 Faucet LED indicators NOTE Wi Fi icon will only illuminate red if the device was previously connected but now can no longer connect router unplugged changed Wi Fi password router h...

Page 16: ...sure seem low there won t be very much water in the storage tank Check the shut off valve on the storage tank to be sure it is open Constant Running to Drain The system should run a small amount of wa...

Page 17: ...iciency of the system in order to determine when the RO membrane should be replaced and ensure the system is working properly Any time the water is going to be turned off to the unit the power should...

Page 18: ...articulate class 1 and chloramine and NSF ANSI 53 for the reduction of cyst lead mercury VOC MTBE perfluooroctanoic acid PFOA and perfluorooctane sulfonate PFOS and NSF ANSI 58 for the reduction of cy...

Page 19: ...00 10 1 3 96 5 97 6 99 1 99 2 99 2 99 1 99 2 99 2 Flouride 8 0 10 1 5 96 3 95 2 97 6 96 8 96 8 97 6 96 8 96 8 Radium 226 2282 25 pCi L 10 5 pCi L 97 8 98 2 99 0 99 0 99 0 99 0 99 0 99 0 Selenium 0 10...

Page 20: ...PID NSF ANSI Standard 53 Substance Influent Challenge Concen tration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model TD 1 Model TD 2 Aqua sential RO Aq...

Page 21: ...97 5 Atenolol Tenormin 200 ng L 20 30 ng L 85 0 94 2 94 2 94 2 94 2 94 2 94 2 94 2 DEET DEET 1 400 20 200 ng L 85 71 98 7 98 7 98 7 98 7 98 7 98 7 98 7 Linuron Linuron 140 20 20 ng L 85 71 96 6 96 6 9...

Page 22: ...tance Influent Challenge Concen tration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model TD Min 1 Model TD Min 2 Aqua sential RO Aqua sential Smart RO A...

Page 23: ...7 5 97 5 Atenolol Tenormin 200 ng L 20 30 ng L 85 0 94 2 94 2 94 2 94 2 94 2 94 2 94 2 DEET DEET 1 400 20 200 ng L 85 71 98 7 98 7 98 7 98 7 98 7 98 7 98 7 Linuron Linuron 140 20 20 ng L 85 71 96 6 96...

Page 24: ...0 088 0 005 1 1 Dichloroethylene 0 083 0 001 Cis 1 2 Dichloroethylene 0 170 0 001 Trans 1 2 Dichloroethylene 0 086 0 001 1 2 Dichloropropane 0 080 0 001 Cis 1 3 Dichloropropylene 0 079 0 001 Dinoseb 0...

Page 25: ...oethane 0 081 0 001 Tetrachloroethylene 0 081 0 001 Toluene 0 078 0 001 2 4 5 tp Silvex 0 270 0 002 Tribromoacetic Acid 0 042 0 001 1 2 4 Trichlorobenzene 0 160 0 001 1 1 1 Trichloroethane 0 084 0 005...

Page 26: ...Concentration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model Aquasential RO Pre 1 RO 50 and Post Adv 1 Aquasential Smart RO Pre 1 RO 75 and Post Adv...

Page 27: ...rivalent reduction See Arsenic Fact section for an explanation of reduction performance NSF ANSI Standard 53 Substance Influent Challenge Concen tration Maximum Permissible Product Water Concen tratio...

Page 28: ...6 97 6 Lead 0 16 0 003 0 005 98 1 98 1 Nitrate5 27 0 10 10 0 72 7 72 7 Nitrite 3 0 10 1 0 73 9 73 9 Radium 226 2283 25pCi L 5pCi L 5pCi L 99 0 99 0 Selenium 0 104 0 0016 0 00205 98 5 98 5 Cyst4 50 000...

Page 29: ...99 2 Fluoride 8 2 0 3 0 039 96 8 96 8 Lead 0 16 0 002 0 002 Nitrate5 27 0 10 10 0 Nitrite 3 0 10 1 0 Radium 226 2283 25pCi L 5pCi L 5pCi L 99 0 99 0 Selenium 0 104 0 0016 0 00182 98 5 98 5 Cyst4 50 0...

Page 30: ...Tank 34 1 gpd Prod Rate without Storage Tank To Atmosphere 34 1 gpd Efficiency Rating2 54 7 Recovery Rating3 52 8 Influent Challenge Concentration Mg L 737 Max Permissible Product Water Concentration...

Page 31: ...d on water supplies containing a detectable free chlorine residual or on water supplies that have been demonstrated to contain only pentavalent arsenic Treatment with chloramine combined chlorine is n...

Page 32: ...No Date Installed For Service Call Culligan at Date Serviced Cartridge s Changed Feed TDS Product TDS 1 Port Prefilter 2 Port RO Membrane 3 Port Specialty Filter 4 Port Postfilter 32 01040605 A 06 21...

Page 33: ...iod specified above for the entire conditioner As a manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing a water treatment system The qualit...

Reviews: