background image

We encourage Culligan users to learn about Culligan products, but we believe that product knowledge is best obtained by 

consulting with your Culligan dealer� Untrained individuals who use this manual assume the risk of any resulting property 

damage or personal injury�

WARNING! 

 

Electrical shock hazard! Prior to servicing equipment, disconnect power supply to prevent electrical shock. 

WARNING! 

 

If incorrectly installed, operated, or maintained, this product can cause severe injury. Those who install, 

operate, or maintain this product should be trained in its proper use, warned of its dangers, and should 

read the entire manual before attempting to install, operate, or maintain this product. Failure to comply 

with any warning or caution that results in any damage will void the warranty.

WARNING! 

 

This device complies with Part 15 of the FCC rules subject to the two following conditions: 1) This 

device may not cause harmful interference, and 2) This device must accept all interference received, 

including interference that may cause undesired operation.

WARNING! 

 

This equipment complies with Part 15 of the FCC rules. Any changes or modifications not expressly 

approved by the manufacturer could void the user’s authority to operate the equipment. Changes or 

modifications not expressly approved by the party responsible for compliance could void the user’s 

authority to operate the equipment.

WARNING! 

 

Connect only to a circuit that is protected by a ground-fault circuit interrupter (GFCI).  

GROUNDING INSTRUCTIONS – This appliance must be grounded. In the event of a malfunction or 

breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for 

electric current. This appliance is equipped with a cord having an appliance-grounding conductor and 

a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in 

accordance with all local codes and ordinances.

WARNING! 

 

Improper connection of the appliance-grounding conductor can result in a risk of electric shock. 

Check with a qualified electrician or service representative if you are in doubt whether the appliance is 

properly grounded. Do not modify the plug provided with the appliance; if it will not fit theoutlet, have a 

proper outlet installed by a qualified technician.

WARNING! 

 

For Indoor Use Only. System is to use a Culligan P/N 01038111 (North America) or P/N 01040549 (EU)  

UL listed Class 2 direct 12 VDC plug-in power unit only.

WARNING! 

 

If connection is made to a potable water system, the system shall be protected against backflow.

WARNING! 

 

This system is to be supplied with cold water only.

CAUTION! 

 

This product is not to be used by children or persons with reduced physical, sensory or mental 

capabilities, or lack of experience or knowledge, unless they have been given supervision or 

instruction. Children should be instructed not to play with this appliance.

CAUTION! 

 

If the power cord from the power supply to the unit looks or becomes damaged, the cord and power 

supply should be replaced in order to avoid a hazard.

5

01040605  A  06/21

Attention Culligan Customer:

Summary of Contents for Aquasential RO

Page 1: ...Aquasential RO and Smart RO Advanced Drinking Water Systems Models from 2021 DCO 210105 06 03 21 CAT 01040605 Rev A 2021 Culligan International Company...

Page 2: ...Analytical Laboratory is certified to perform coliform and E coli testing We strive to provide our customers with the testing they need at the lowest possible cost with the quickest turn around time S...

Page 3: ...Customer 5 Thank You 7 Specifications 9 Application Operation 11 Navigation 14 Things to Check Before You Call 16 Care Cleaning 17 Performance Data Sheet 18 Records Data 32 Culligan Limited Warranty 3...

Page 4: ...paragraphs are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and careful attention are conditions which cannot be built into...

Page 5: ...und fault circuit interrupter GFCI GROUNDING INSTRUCTIONS This appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a pat...

Page 6: ...is 25 2 C The full battery charging cycle 6 0V to 8 4V takes approximately 8 5 hours As a safety precaution charging terminates after 11 25 hours To start charging plug the 12V power supply in the fro...

Page 7: ...for specific performance claims as verified and substantiated by test data See performance data sheet included in this manual for specific claims Model ESP32 WROOM 32D used in Aquasential Smart RO Con...

Page 8: ...ion Sciences et D veloppement conomique Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouil...

Page 9: ...er than 10 gpg will reduce the life of the membrane The Arsenic cartridge must be installed after the RO membrane All specialty cartridges must have a Performance Indicator Device PID installed to tra...

Page 10: ...eral TD Min 1 1 year or 1 000 gallons TD Min 2 2 year or 2 000 gallons Specialty Remineralization Min 1 1 year or 1 000 gallons Min 2 2 year or 2 000 gallons Specialty Arsenic AS3 1 1 year or 1 000 ga...

Page 11: ...te Total Dissolved Solids The minimum driving force which is necessary to stop or reverse the natural osmosis process is termed osmotic pressure As the total dissolved solids level of the feed water i...

Page 12: ...e only a certain percentage of contaminants can pass through Reverse Osmosis can reduce up to 99 of contaminants Advanced Filtration The advanced filtration cartridges are specifically designed to red...

Page 13: ...h lab For more information please contact your local Culligan dealer Additional information about the arsenic in water can be found through the EPA s website at www epa gov There are two forms of arse...

Page 14: ...ed Wi Fi blinks during Bluetooth pairing Blue blink Wi Fi blinks during Wi Fi pairing Green blink Wi Fi when Wi Fi connection lost Red blink LED Indicators on the RO unit 1 Year Filter 2 Year Filter I...

Page 15: ...is in use Figure 2 Faucet LED indicators NOTE Wi Fi icon will only illuminate red if the device was previously connected but now can no longer connect router unplugged changed Wi Fi password router h...

Page 16: ...sure seem low there won t be very much water in the storage tank Check the shut off valve on the storage tank to be sure it is open Constant Running to Drain The system should run a small amount of wa...

Page 17: ...iciency of the system in order to determine when the RO membrane should be replaced and ensure the system is working properly Any time the water is going to be turned off to the unit the power should...

Page 18: ...articulate class 1 and chloramine and NSF ANSI 53 for the reduction of cyst lead mercury VOC MTBE perfluooroctanoic acid PFOA and perfluorooctane sulfonate PFOS and NSF ANSI 58 for the reduction of cy...

Page 19: ...00 10 1 3 96 5 97 6 99 1 99 2 99 2 99 1 99 2 99 2 Flouride 8 0 10 1 5 96 3 95 2 97 6 96 8 96 8 97 6 96 8 96 8 Radium 226 2282 25 pCi L 10 5 pCi L 97 8 98 2 99 0 99 0 99 0 99 0 99 0 99 0 Selenium 0 10...

Page 20: ...PID NSF ANSI Standard 53 Substance Influent Challenge Concen tration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model TD 1 Model TD 2 Aqua sential RO Aq...

Page 21: ...97 5 Atenolol Tenormin 200 ng L 20 30 ng L 85 0 94 2 94 2 94 2 94 2 94 2 94 2 94 2 DEET DEET 1 400 20 200 ng L 85 71 98 7 98 7 98 7 98 7 98 7 98 7 98 7 Linuron Linuron 140 20 20 ng L 85 71 96 6 96 6 9...

Page 22: ...tance Influent Challenge Concen tration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model TD Min 1 Model TD Min 2 Aqua sential RO Aqua sential Smart RO A...

Page 23: ...7 5 97 5 Atenolol Tenormin 200 ng L 20 30 ng L 85 0 94 2 94 2 94 2 94 2 94 2 94 2 94 2 DEET DEET 1 400 20 200 ng L 85 71 98 7 98 7 98 7 98 7 98 7 98 7 98 7 Linuron Linuron 140 20 20 ng L 85 71 96 6 96...

Page 24: ...0 088 0 005 1 1 Dichloroethylene 0 083 0 001 Cis 1 2 Dichloroethylene 0 170 0 001 Trans 1 2 Dichloroethylene 0 086 0 001 1 2 Dichloropropane 0 080 0 001 Cis 1 3 Dichloropropylene 0 079 0 001 Dinoseb 0...

Page 25: ...oethane 0 081 0 001 Tetrachloroethylene 0 081 0 001 Toluene 0 078 0 001 2 4 5 tp Silvex 0 270 0 002 Tribromoacetic Acid 0 042 0 001 1 2 4 Trichlorobenzene 0 160 0 001 1 1 1 Trichloroethane 0 084 0 005...

Page 26: ...Concentration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model Aquasential RO Pre 1 RO 50 and Post Adv 1 Aquasential Smart RO Pre 1 RO 75 and Post Adv...

Page 27: ...rivalent reduction See Arsenic Fact section for an explanation of reduction performance NSF ANSI Standard 53 Substance Influent Challenge Concen tration Maximum Permissible Product Water Concen tratio...

Page 28: ...6 97 6 Lead 0 16 0 003 0 005 98 1 98 1 Nitrate5 27 0 10 10 0 72 7 72 7 Nitrite 3 0 10 1 0 73 9 73 9 Radium 226 2283 25pCi L 5pCi L 5pCi L 99 0 99 0 Selenium 0 104 0 0016 0 00205 98 5 98 5 Cyst4 50 000...

Page 29: ...99 2 Fluoride 8 2 0 3 0 039 96 8 96 8 Lead 0 16 0 002 0 002 Nitrate5 27 0 10 10 0 Nitrite 3 0 10 1 0 Radium 226 2283 25pCi L 5pCi L 5pCi L 99 0 99 0 Selenium 0 104 0 0016 0 00182 98 5 98 5 Cyst4 50 0...

Page 30: ...Tank 34 1 gpd Prod Rate without Storage Tank To Atmosphere 34 1 gpd Efficiency Rating2 54 7 Recovery Rating3 52 8 Influent Challenge Concentration Mg L 737 Max Permissible Product Water Concentration...

Page 31: ...d on water supplies containing a detectable free chlorine residual or on water supplies that have been demonstrated to contain only pentavalent arsenic Treatment with chloramine combined chlorine is n...

Page 32: ...No Date Installed For Service Call Culligan at Date Serviced Cartridge s Changed Feed TDS Product TDS 1 Port Prefilter 2 Port RO Membrane 3 Port Specialty Filter 4 Port Postfilter 32 01040605 A 06 21...

Page 33: ...iod specified above for the entire conditioner As a manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing a water treatment system The qualit...

Reviews: