Important Notice 

— 

Read this data sheet and compare the capabilities of the unit to your actual water treatment needs� Culligan recommends that 

you have your water supply tested to determine these needs before purchasing a water treatment unit�
Culligan knows the more informed you are about your water treatment system, the more confident you will be about its performance� It’s because 

of this and more than seventy years of commitment to our customers that Culligan is providing this Performance Data Sheet to its customers�

Manufacturer

 

Culligan International Company 

 

 

9399 W� Higgins Rd�, Suite 1100, Rosemont, IL 60018 USA 

 

 

1-800-CULLIGAN or 1-847-430-2800

  

www�culligan�com

Product:

   Culligan

®

 Aquasential

®

 RO and Smart RO Advanced Drinking Water Systems 

Models: 

  Aquasential RO, Aquasential RO (2yr), Aquasential Smart RO, Aquasential Smart RO (2yr)

Product Specifications 

Daily Production Rate:  

Aquasential RO = 27�8 gpd   

Electrical Requirements:  

12VDC, 20W (for Smart RO only) 

 

 

 

Aquasential Smart RO = 34�1 gpd 

 

 

 

 

Operating Temp� Range:  

33-100°F (0�5–38°C)  

 

 

Working Press� Range:  

40–120 psi (2�8–11 kg/cm²)   

Use Guidelines:

•  These systems must be installed according to local plumbing codes on the cold water line�

•  These systems requires regular replacement of all filters to maintain proper operation� Depending on usage and influent water 

quality, the carbon, Mineral Boost, and particulate filters should be changed at least annually and the reverse osmosis membrane 

should be replaced every 3-5 years� Varying chlorine, sediment or TDS levels may affect replacement frequency�

CAUTION! 

 

Do not use with water that is microbiologically unsafe or of unknown quality without adequate 

disinfection before or after the systems. Systems certified for cyst reduction may be used on 

disinfected water that may contain filterable cysts.

The Aquasential

®

 RO and Smart RO Advanced Drinking Water Systems are tested and certified by WQA to CSA 

B483�1, NSF/ANSI 372, NSF/ANSI 42 for the reduction of aesthetic chlorine, taste and odor, nominal particulate class 1 

and chloramine, and NSF/ANSI 53 for the reduction of cyst, lead, mercury, VOC, MTBE, perfluooroctanoic acid (PFOA) 

and perfluorooctane sulfonate (PFOS), and NSF/ANSI 58 for the reduction of cyst, TDS, turbidity, pentavalent arsenic, 

barium, cadmium, hexavalent and trivalent chromium, copper, lead*, nitrate/nitrite*, radium 226/228, fluoride and 

selenium, and NSF/ANSI 401 for the reduction of phenytoin, ibuprofen, naproxen, estrone, bisphenol A, nonylphenol, 

atenolol, DEET, linuron, carbamazepine, trimethoprim, metolachlor, TCEP, TCPP and meprobamate, NSF Protocol 

P231 for bacteria, virus and some cysts reduction, as verified and substantiated by test data�
The substances removed by these systems are not necessarily in the customer’s untreated water�
¹ Recovery rating means the percentage of the influent water to the membrane portion of the systems that are available to the user as 

reverse osmosis treated water when the systems are operated without a storage tank or when the storage tank is bypassed� These 

systems have been tested and shown to operate at their calculated recovery rating under standard laboratory conditions�
* Smart RO is not evaluated by WQA for lead or nitrate/nitrite�
To maintain product certification and ensure uniform performance, the product is retested on a consistent basis�
These systems have been tested and shown to operate at their calculated recovery rating under standard laboratory conditions�
These reverse osmosis systems contains a replaceable component critical to the efficiency of the systems� Replacement of the reverse 

osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure the same efficiency and 

contaminant reduction performance�
Refer to your Owner's Guide and printed limited Warranties (P/N 01040605) for more specific product information� To avoid contamination 

from improper handling and installation, your systems should only be installed and serviced by your Culligan dealer� Performance will 

vary based on local water conditions� The substances reduced by these systems are not necessarily in your water�

Buyer Signature  _______________________     Date  ____________
Seller Signature  _______________________     Date  ____________

18

01040605  A  06/21

Performance Data Sheet

Summary of Contents for Aquasential RO

Page 1: ...Aquasential RO and Smart RO Advanced Drinking Water Systems Models from 2021 DCO 210105 06 03 21 CAT 01040605 Rev A 2021 Culligan International Company...

Page 2: ...Analytical Laboratory is certified to perform coliform and E coli testing We strive to provide our customers with the testing they need at the lowest possible cost with the quickest turn around time S...

Page 3: ...Customer 5 Thank You 7 Specifications 9 Application Operation 11 Navigation 14 Things to Check Before You Call 16 Care Cleaning 17 Performance Data Sheet 18 Records Data 32 Culligan Limited Warranty 3...

Page 4: ...paragraphs are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and careful attention are conditions which cannot be built into...

Page 5: ...und fault circuit interrupter GFCI GROUNDING INSTRUCTIONS This appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a pat...

Page 6: ...is 25 2 C The full battery charging cycle 6 0V to 8 4V takes approximately 8 5 hours As a safety precaution charging terminates after 11 25 hours To start charging plug the 12V power supply in the fro...

Page 7: ...for specific performance claims as verified and substantiated by test data See performance data sheet included in this manual for specific claims Model ESP32 WROOM 32D used in Aquasential Smart RO Con...

Page 8: ...ion Sciences et D veloppement conomique Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouil...

Page 9: ...er than 10 gpg will reduce the life of the membrane The Arsenic cartridge must be installed after the RO membrane All specialty cartridges must have a Performance Indicator Device PID installed to tra...

Page 10: ...eral TD Min 1 1 year or 1 000 gallons TD Min 2 2 year or 2 000 gallons Specialty Remineralization Min 1 1 year or 1 000 gallons Min 2 2 year or 2 000 gallons Specialty Arsenic AS3 1 1 year or 1 000 ga...

Page 11: ...te Total Dissolved Solids The minimum driving force which is necessary to stop or reverse the natural osmosis process is termed osmotic pressure As the total dissolved solids level of the feed water i...

Page 12: ...e only a certain percentage of contaminants can pass through Reverse Osmosis can reduce up to 99 of contaminants Advanced Filtration The advanced filtration cartridges are specifically designed to red...

Page 13: ...h lab For more information please contact your local Culligan dealer Additional information about the arsenic in water can be found through the EPA s website at www epa gov There are two forms of arse...

Page 14: ...ed Wi Fi blinks during Bluetooth pairing Blue blink Wi Fi blinks during Wi Fi pairing Green blink Wi Fi when Wi Fi connection lost Red blink LED Indicators on the RO unit 1 Year Filter 2 Year Filter I...

Page 15: ...is in use Figure 2 Faucet LED indicators NOTE Wi Fi icon will only illuminate red if the device was previously connected but now can no longer connect router unplugged changed Wi Fi password router h...

Page 16: ...sure seem low there won t be very much water in the storage tank Check the shut off valve on the storage tank to be sure it is open Constant Running to Drain The system should run a small amount of wa...

Page 17: ...iciency of the system in order to determine when the RO membrane should be replaced and ensure the system is working properly Any time the water is going to be turned off to the unit the power should...

Page 18: ...articulate class 1 and chloramine and NSF ANSI 53 for the reduction of cyst lead mercury VOC MTBE perfluooroctanoic acid PFOA and perfluorooctane sulfonate PFOS and NSF ANSI 58 for the reduction of cy...

Page 19: ...00 10 1 3 96 5 97 6 99 1 99 2 99 2 99 1 99 2 99 2 Flouride 8 0 10 1 5 96 3 95 2 97 6 96 8 96 8 97 6 96 8 96 8 Radium 226 2282 25 pCi L 10 5 pCi L 97 8 98 2 99 0 99 0 99 0 99 0 99 0 99 0 Selenium 0 10...

Page 20: ...PID NSF ANSI Standard 53 Substance Influent Challenge Concen tration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model TD 1 Model TD 2 Aqua sential RO Aq...

Page 21: ...97 5 Atenolol Tenormin 200 ng L 20 30 ng L 85 0 94 2 94 2 94 2 94 2 94 2 94 2 94 2 DEET DEET 1 400 20 200 ng L 85 71 98 7 98 7 98 7 98 7 98 7 98 7 98 7 Linuron Linuron 140 20 20 ng L 85 71 96 6 96 6 9...

Page 22: ...tance Influent Challenge Concen tration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model TD Min 1 Model TD Min 2 Aqua sential RO Aqua sential Smart RO A...

Page 23: ...7 5 97 5 Atenolol Tenormin 200 ng L 20 30 ng L 85 0 94 2 94 2 94 2 94 2 94 2 94 2 94 2 DEET DEET 1 400 20 200 ng L 85 71 98 7 98 7 98 7 98 7 98 7 98 7 98 7 Linuron Linuron 140 20 20 ng L 85 71 96 6 96...

Page 24: ...0 088 0 005 1 1 Dichloroethylene 0 083 0 001 Cis 1 2 Dichloroethylene 0 170 0 001 Trans 1 2 Dichloroethylene 0 086 0 001 1 2 Dichloropropane 0 080 0 001 Cis 1 3 Dichloropropylene 0 079 0 001 Dinoseb 0...

Page 25: ...oethane 0 081 0 001 Tetrachloroethylene 0 081 0 001 Toluene 0 078 0 001 2 4 5 tp Silvex 0 270 0 002 Tribromoacetic Acid 0 042 0 001 1 2 4 Trichlorobenzene 0 160 0 001 1 1 1 Trichloroethane 0 084 0 005...

Page 26: ...Concentration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model Aquasential RO Pre 1 RO 50 and Post Adv 1 Aquasential Smart RO Pre 1 RO 75 and Post Adv...

Page 27: ...rivalent reduction See Arsenic Fact section for an explanation of reduction performance NSF ANSI Standard 53 Substance Influent Challenge Concen tration Maximum Permissible Product Water Concen tratio...

Page 28: ...6 97 6 Lead 0 16 0 003 0 005 98 1 98 1 Nitrate5 27 0 10 10 0 72 7 72 7 Nitrite 3 0 10 1 0 73 9 73 9 Radium 226 2283 25pCi L 5pCi L 5pCi L 99 0 99 0 Selenium 0 104 0 0016 0 00205 98 5 98 5 Cyst4 50 000...

Page 29: ...99 2 Fluoride 8 2 0 3 0 039 96 8 96 8 Lead 0 16 0 002 0 002 Nitrate5 27 0 10 10 0 Nitrite 3 0 10 1 0 Radium 226 2283 25pCi L 5pCi L 5pCi L 99 0 99 0 Selenium 0 104 0 0016 0 00182 98 5 98 5 Cyst4 50 0...

Page 30: ...Tank 34 1 gpd Prod Rate without Storage Tank To Atmosphere 34 1 gpd Efficiency Rating2 54 7 Recovery Rating3 52 8 Influent Challenge Concentration Mg L 737 Max Permissible Product Water Concentration...

Page 31: ...d on water supplies containing a detectable free chlorine residual or on water supplies that have been demonstrated to contain only pentavalent arsenic Treatment with chloramine combined chlorine is n...

Page 32: ...No Date Installed For Service Call Culligan at Date Serviced Cartridge s Changed Feed TDS Product TDS 1 Port Prefilter 2 Port RO Membrane 3 Port Specialty Filter 4 Port Postfilter 32 01040605 A 06 21...

Page 33: ...iod specified above for the entire conditioner As a manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing a water treatment system The qualit...

Reviews: