CULITEK IMCT-66 Instruction Manual Download Page 1

Undercounte

r Ice Machines

A Professional Line of Commercial Refrigerated Equipment

Instruction Manual

Undercounte

r Ice Machine

s

MODEL

S

:

  

IMCT-

66, IMCT-77, IMCT-120, 

IMCT-160, UMCT-210, IMCT-280 

This manual contains important information regarding your Culitek unit.  Please read this manual 

thoroughly prior to equipment set-up, operation and maintenance.  Failure to comply with regular 

maintenance guidelines outlined in this manual may void the warranty.

Summary of Contents for IMCT-66

Page 1: ...chines MODELS IMCT 66 IMCT 77 IMCT 120 IMCT 160 UMCT 210 IMCT 280 This manual contains important information regarding your Culitek unit Please read this manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maintenance guidelines outlined in this manual may void the warranty ...

Page 2: ...st 8 and 6 on each side Clearance in front should be at least 12 This is to allow for proper air discharge from the unit while it s running If the minimal clearance on all sides is reduced ice capacity will be reduced For best results do not install next to heat producing appliances 2 The ambient temperature where this unit is going to be installed should have a minimum of 40 F and a maximum of 10...

Page 3: ...rator and will form ice cubes in the ice tray ICE FALL When the machine has reached its capacity the pump will shut down and the frost valve will open allowing hot air into the evaporator In approximately 1 2 minutes the ice from the evaporator will fall into the ice bin In order to avoid injury do not put your hands into the ice bin during this process SHUTDOWN If the machine is running and needs...

Page 4: ...unit will circulate the descaler drain and flush it through the internal water system This process will take about 20 30 minutes Once completed the machine will stop circulating 6 To clean the internal components in a pail mix together 1 oz of descaler to 12 ounces of water The components that need to be sanitized are the water distributor ice thickness sensor adjustment screw water level sensor a...

Page 5: ... the water line Check the water level Make sure inlet valve is working Check water pressure Clear pipeline if needed Slow ice production Condenser is dirty Ambient temperature is too high Not enough airflow clearance around the unit Clean the air filter and condenser Lower the ambient temperature Check to make sure there is adequate space for airflow around the unit TROUBLESHOOTING Code Annotation...

Page 6: ...Exploded Diagram for IMCT 66 ...

Page 7: ...Exploded Diagram for IMCT 77 ...

Page 8: ...ty and the additional four 4 year compressor warranty as described above These warranties are exclusive and in lieu of all other warranties including implied warranty and merchantability or fitness for a particular purpose There are no warranties which extend beyond the description on the face hereof 5 TRANSPORTATION COSTS Will accept parts covered under this warranty freight collect provided that...