background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CTC Union Technologies Co.,Ltd. 

Far Eastern Vienna Technology Center 
(Neihu Technology Park) 
8F, No. 60 Zhouzi St., Neihu, Taipei 114, 
Taiwan 
 
 
 

 +886-2-26591021 

 +886-2-26590237 

E

  [email protected] 

[email protected] 
[email protected] 

H

  www.ctcu.com 

 

 
 
 
 

2011 CTC Union Technologies Co., LTD. 
All trademarks are the property of their respective owners. 
Technical information in this document is subject to 
change without notice.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for FRM220-FOM01

Page 1: ...houzi St Neihu Taipei 114 Taiwan T 886 2 26591021 F 886 2 26590237 E sales ctcu com info ctcu com marketing ctcu com H www ctcu com 2011 CTC Union Technologies Co LTD All trademarks are the property of their respective owners Technical information in this document is subject to change without notice ...

Page 2: ...te of this multiplexer employs either fixed transceiver or industry standard pluggable optics SFP that operate at OC3 STM 1 data rates 155M depending on model The aggregate can be chosen to support any of the following Single mode Multi mode Single fiber bi directional Coarse and Dense Wave Division Multiplexing CWDM and DWDM Features 1 channel unframed E1 T1 plus wire speed 10 100Base TX Ethernet...

Page 3: ...ches making it completely software configurable When placed in a stand alone chassis this device supports a text based serial terminal with an easy to use menu system for configuration When placed in a managed chassis FOM01 is configured and monitored through chassis NMC network management controller via console Telnet Web HTTP or SNMP 1 Stand alone with serial console and menu driven settings 2 R...

Page 4: ...Win7 FOM01 with CH01M uses the DB9 serial connector labeled CONSOLE and a DB9M to DB9F one to one cable to connect to the PC COM port Connect the DB9F labeled CONSOLE to the COM port of the management PC When placed in CH02M chassis connect console to CH02M s DB9F and slide the switch to the right slot number Settings Baud Rate 38 400 Data bits 8 Parity bits none Stop bits 1 Flow Control none Emul...

Page 5: ... to the main menu CTC UNION TECHNOLOGIES CO LTD FRM220 FOM01 Manager Ver 1 00 Local Version 1 000 1 000 0 000 1 200 FOM01 SFP CH01M Device Service Select 1 Service On 2 Service Off ESC Go to previous menu Please select an item 7 w w w C T C U c o m Fiber From the main menu select item number 2 to access the fiber status menu Note Tx Power Rx Power Rx Sensitivity and Temperature are only available ...

Page 6: ...em E1 T1 Loop Back Test Function Select 1 Disable 2 LLB 3 RLB ESC Go to previous menu Please select an item 9 w w w C T C U c o m LAN From the main menu select item number 4 to access the LAN status menu 1 LAN Service Enable or disable the transmission on the LAN trunk 2 Negotiation This LAN port supports both auto negotiation per IEE802 3u and manual forced mode When in auto the speed and duplex ...

Page 7: ...20 FOM01 Set local and remote multiplexers to the right E1 T1 transport and enable the port Configure the LAN port for proper connection either with auto negotiation or by manual forced mode An in band management channel will transparently carry configuration data from remote side equipment back to the central side for remote management For normal operation ensure that all Loop Backs are disabled ...

Page 8: ...FRM220 3R 2 7G 2S 3S C FRM220 5E1 ET100T D FRM220 5E1 ET100S E FRM220 Eoe1 F FRM220 3R 10G SS SX XX G FRM220 3R 10G SS SX XX CDR H FRM220 MUX DEMUX I FRM220 E1 DATA J FRM220 FOM04 K FRM220 FOM04 FPGA M FTEC N 2R 4G 2S 3S O FRM220 3R 10G SXX P FRM220 3R 10G SXX CDR Q FRM220 FOM01 R FRM220 FOM01 FPGA ESC Previous Menu 13 w w w C T C U c o m About SFP Units FRM220 FOM01 SFP accepts any SFP unit that ...