2.6 NMC Card Installation
Slot number 1 of the chassis is reserved for the Network Management Controller (NMC). The NMC card
provides the full network management features. When the NMC is installed, the rack and all line cards become
manageable by industry standard SNMP protocol. (Please refer to Chapter 3 for more information on the operation
of the network management features). The remaining slots, numbered 2 through 8, may contain any other FRM220
Series In-band Managed fiber media converter card.
Figure 2-7 NMC removal/replacement in slot number 1
IMPORTANT:
In the FRM220 In-Band Managed Rack, slot number1 must contain an NMC card. In a chassis where non-
managed line cards are employed (cards that use DIP switch settings), slot number 1 may then be used for a non-managed
media converter line card.
2.7 Line Card Installation
The Line Cards for the
FRM220 Series
are Fiber Media Converter Cards which slide into
CH08
chassis, and
interface with the back panel "main board". The back panel provides a connection to the converter cards for power
and serial control.
The media converter cards are designed to be "hot" swappable, meaning
CH08
chassis need not be powered
off in order to remove or replace a card. Removal and installation of converter cards with the rack chassis under
power will not affect the operation of other converter cards.
Removal of a converter card is accomplished by loosening the one (1) captive screw (right) and then pulling the
card straight out of the chassis with the same screw. Replace the card by reversing the procedure, align in the slot
groove and gently seat the card, retightening the captive screw.
Figure 2-8 Line card removal/replacement