Chapter 2 Installation
12
DC
Alarm 1 Alarm2
Programmable alarm relays
AC
FRM220-CH20
Light, Visual Alarm
Siren, Audible Alarm
2.4 Electrical Installation
With an AC power module, AC power is supplied to
CH08
through a standard IEC C14 3-prong receptacle,
located on the rear of the module. Any national power cord with IEC C13 line plug may be used to connect AC
power to the power module. With a DC24 or DC48 module, DC voltage is connected to the terminal block located
on the rear of the module, observing the proper polarity.
CH08
should always be grounded through the protective
earth lead of the power cable in AC installations, or via the frame ground connection for DC installations.
Figure 2-4 IEC (AC) & terminal block (DC) power connector pin assignment
2.5 Alarm Installation
The alarm relay provides one set of Power Failure contacts (normally open) and another set of FAN Failure
contacts (normally open) contacts for monitoring the power and fans condition of
CH08
. The alarm contacts may
also be programmed through the management interface to react to different fault conditions.
Figure 2-5 Alarm Relay Contacts
Figure 2-6 Example of electrical circuit for visual and audible alarms
Left: Live line
Right: Neutral line
Middle: Ground
Left: -V (-48V)
Right: +V (0V)
Middle: Frame Ground
DC IN
-V FG +V
36~60VDC
18~36VDC
IEC C13 line plug
125VAC
1A
110VDC
0.6A
30VDC
4A
Alarm Contacts
1 2
FRM220-CH08