HV Breakout Module – Appendix
Installation Manual
40
Version 01.20 // 2021
Fig. 7-8: Step 5: Attaching and fixing the shrink sleeve
"
Slide a 10 mm long piece of shrink sleeve over the HV power cable up to
the marking (Fig. 7-7).
"
Fix the shrink sleeve by applying heat.
Fig. 7-9: Step 6: Dismantling the wire
"
Remove the inner sheath to the required length.
17
Fig. 7-10: Step 7: Sliding the shrink sleeve over the cable and attaching the ring terminal
"
Slide an approx. 25 mm long piece of shrink sleeve over the cable.
"
Attach the ring terminal to the dismantled wire.
"
Use the crimping pliers to crimp the ring terminal at two points and then solder it.
Fig. 7-11: Step 8: Placing and fixing the shrink sleeve
"
Slide the shrink sleeve over the crimped end of the ring terminal so that
about 15 mm of the shrink sleeve will cover the ring terminal.
"
Fix the shrink sleeve by applying heat.
→ For information on how to connect the HV power cables to the measurement module,
please refer to chapter 4.3.3.3 "HV BM 1.x: Connecting the HV power cables".
17 Stripping length of the inner sheath depending on the cable cross section: 35 mm²: 20 mm, 50 mm²: 12 mm,
70 mm²: 15 mm, 95 mm²: 25 mm