SIGNATURE  SERIES                                                                                        

-Drain Line Connection-

1. Pull out clip and remove drain line assembly located on the left side of control valve. Remove drain line hose barb and    
    wrap threads with Teflon tape. Reinstall drain line hose barb. Caution: Hand tighten only!! Replace drain line assembly   
    and reinstall clip.
2. Install 1/2” I.D. drain line tubing (not included) from hose barb to an open drain. A 4” gap between the end of the drain    
    line and the open drain is required to prevent waste water backflow. Keep the drain line as short as possible. An  

 

    overhead drain line can be used if necessary, but should discharge below the control valve. A siphon trap (taped loop)    
    at the outlet of the drain line is advisable to keep the drain line full and assure correct flow during regeneration. 
    Elbows or other fittings must be kept at a bare minimum.

Note: 

Where the drain line is elevated above the control valve or exceeds 20 feet in length, 3/4” I.D. drain line tubing    

   

          should be used.

 -Brine Line and Overflow Connection-

1. Position brine tank on a smooth, level surface near the softener resin tank. If necessary, the brine tank can be placed at  
    a higher level than the resin tank, but never at a lower level.
2. Install one end of 3/8” O.D. by 1/4” I.D. brine line tubing (included with unit) to compression fitting located on left side of   
    control valve.
3. Remove brine tank cover.
4. Remove cap from brine well.
5. Insert opposite end of brine line through outer hole in brine tank.
6. Connect brine line to push lock fitting on safety brine valve located inside brine well. Replace brine well cap.
7. Install 1/2” I.D. drain line tubing (not included) to the overflow fitting on brine tank located just below the brine line.
8. Run the opposite end of brine tank drain line to a suitable drain.
9.   Install optional RK15 Res-Care Feeder in brine tank per instructions.  (Sold Separately!)

Note:

 The brine tank drain line is gravity flow and must discharge below the overflow fitting.

Caution: 

Do not TEE to the main drain line from control valve.

Notice:

 The brine overflow is provided as a back-up in the event the safety float shut-off should fail, allowing the brine  

 

 

tank to overfill. This drain connection would then carry the excess water to the drain and prevent flooding of the    

 

floor. Therefore, no liability will or can be assumed by the manufacturer of the softener should this occur.

-Electrical Connection-

1. Connect the power supply to the control valve and plug into a 115 volt / 60 Hz receptacle.

-Installing Battery Back Up-

1. Remove the rear cover.
2. Install a 9 volt battery. Refer to page 3, item 3 of the Signature Series Service Manual.

- Pressurizing The System -

1.  Make certain Signature Series Control Valve is in 

SERVICE 

position.

2.  Slowly rotate bypass valve to the 

SERVICE 

position. 

3.  Open the nearest faucet to evacuate air from plumbing lines.
4.  Check for leaks! If water is observed leaking from bottom of bypass, close and open bypass lever several times to  

          

     seat o-rings.
5.  After air is evacuated from plumbing lines, close bypass (position of bypass lever is perpendicular to the direction of         
     pipes) 

Note :      

Salt settings are pre-set at the factory for the maximum shown on the capacity charts. 

Warning : 

Do not reduce salt settings below 9 lbs. as the water level in the brine tank will not reach the grid plate.

7

Installation

Summary of Contents for Terminatr MSI32

Page 1: ... SIGNATURE SERIES Signature Series Terminatr Installation Operation Manual ...

Page 2: ...ERIES www csiwater com Online at Register Your Product Softener Specifications Page 3 Softener Installation Page 4 Softener Capacity Page 8 Installing the Control Valve Page 10 Error Codes Page 11 Warranty Page 12 ...

Page 3: ...fications 3 General Specifications TSI32 MSI32 TSI48 MSI48 TSI64 MSI64 TSI96 MSI96 Grains Capacity Regeneration Lbs Salt Used Per Tank 35 000 15 32 000 9 26 500 6 52 500 24 48 000 15 39 750 9 70 000 30 64 000 18 53 000 12 105 000 45 96 000 27 85 000 18 Maximum Raw Water Hardness grains 75 100 100 100 Maximum Clear Iron Manganese 15 20 20 20 Exchange Resin cu ft per tank 1 0 1 5 2 0 3 0 Mineral Tan...

Page 4: ...me the sodium ions used for the exchange process become depleted and must be replenished The water softener provides a Regeneration process whereby brine solution enters the mineral tank driving off the collected hardness ions and replenishes the surface of the resin beads with more sodium ions This process is automati cally initiated by the control valve on the mineral tank The regeneration proce...

Page 5: ...cement and plumbing connections Major System Components 1 Brine Tank This tank holds the salt that is added to the softener This salt is dissolved with water to form a brine solution used in the softener regeneration process 2 Resin Tank This tank contains the ion exchange resin media Water flows through the resin tank under pressure to come into contact with the resin for water softening 3 Contro...

Page 6: ... around the softener 1 Position softener at desired location for installation See Installation Diagrams 2 For MSI96 Units ONLY The resin material is shipped separately from the mineral tank Remove the valve by unscrewing from center hole Use a cork or tape to place over top of distributor tube to prevent material from entering tube while filling Place funnel in hole Pour several gallons of water i...

Page 7: ...ce brine well cap 7 Install 1 2 I D drain line tubing not included to the overflow fitting on brine tank located just below the brine line 8 Run the opposite end of brine tank drain line to a suitable drain 9 Install optional RK15 Res Care Feeder in brine tank per instructions Sold Separately Note The brine tank drain line is gravity flow and must discharge below the overflow fitting Caution Do no...

Page 8: ...anual Warning Do not reduce salt setting below 9 lbs as the water level in the brine tank will not reach the grid plate Control Valve Operation 1 Advance control valve to BACKWASH cycle 1 position and allow water to run to drain for 3 to 4 minutes Warning Close valve on bypass prior to selecting the backwash position After backwash position has been established slightly open bypass to evacuate air...

Page 9: ...dule 5 Make final check for leaks 6 Be certain to REGISTER YOUR PRODUCT at www csiwater com 7 Leave all manuals with unit Operation Care and Cleaning When the inlet outlet knobs on the bypass valve are in the SERVICE position position of bypass knobs are parallel to the inlet outlet piping water is directed through the water softener Water may be bypassed by turning the inlet outlet knobs to the b...

Page 10: ...unit Never use harsh abrasive cleaners 3 Protect the water softener and drain line from freezing 4 Reset time for daylight saving time periods 5 Replace 9 volt battery once a year 6 Inspect and clean the brine tank when sediment appears in the bottom of the salt compartment 7 Always keep the brine tank supplied with good quality salt a type designed for use in water softeners ...

Page 11: ...body cycle power to clear the error code Manually cycle the powerhead through the regeneration cycle steps to verify that the motor can cycle properly while the powerhead is disconnected from the valve body If the error 3 does not reappear skip to step 3 below If the error 3 does reappear order a board motor kit to replace the circuit board motor 3 Remove piston and seals from the valve body and i...

Page 12: ...as described in the manual To any failure or malfunction resulting from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water pressure not exceeding 125 psi oth er than CSI storage use operation accident or alteration lightning flooding or other environmental conditions To ...

Reviews: