Crystal Vision
Control and Status monitoring
Resample
Select to enable resampling of the selected stereo pair output from
the de-embedder. Resampling is used to seamlessly match the
timing of audio signals when the user-controlled delay is altered
and is the default condition. If resampling is deselected it is
essential that the input and output source is derived from the same
source and the timing should not be adjusted while on air. Without
resampling, an adjustment in timing will cause a number of audio
samples to
be dropped or repeated. As Dolby E signals cannot be
resampled, the control will be ignored.
Discrete inputs
Monitor external analogue or AES input channel status, invert channels, detect
Dolby E encoded channel pairs, mono and resample stereo pairs. Screen grab
below shows a DIOP4 in the front piggyback position with eight digital inputs.
Present
On when embedded channel detected.
Silent
On if the audio channel is silent i.e. consistently below
the set threshold.
Invert
Select to enable inversion of the de-embedder output for
the selected channel.
Dolby E
On if the channel pair has Dolby E encoding (AES inputs
only).
Mono
Select to mono the channel pair
. N.B. Only the first
channel of the stereo pair is converted to mono, the
second channel is unchanged. The mono output is gain
corrected to maintain unity gain.
SYNNER-VF User Manual R1.1
27
03 January 2017