REMIND 

 

1U remote control panel 

 

 

Summary of Contents for REMIND

Page 1: ... Ltd Lion Technology Park Station Road East Whittlesford Cambridge CB22 4WL England E mail sales crystalvision tv Website www crystalvision tv Tel 44 0 1223 497049 Fax 44 0 1223 497059 REMIND 1U remote control panel ...

Page 2: ... Vision modules designed for that purpose Do not use the frame unless all the rear connector positions are filled either with Crystal Vision Rear Modules or with Crystal Vision blanking plates Only suitably trained personnel should perform service procedures Apart from procedures described in this manual there are no user serviceable parts within the frame If the frame requires any other servicing...

Page 3: ... General Safety Summary 2 Introduction 4 Specification 4 Mains Connections 4 Power Supply 4 Front Panel indication 5 Rear Signal Connections 5 Slot Numbers 7 Front Panel Control Module on the Remind Panel 7 Using the Front Panel Controls 8 Controlling Two Frames From One Panel 8 Replacing a REM1U 8 Maintenance 9 Replacing the mains input fuses 9 ...

Page 4: ...ser adjustment of suitable Crystal Vision modules with a menu driven user interface The Remind front panel Specification Size mm 482 w x 44 h x 90 d Weight 1 0 kg Supply Voltage 110 240Vac 47 400 Hz Amb Temp Range 0 40 O C Mains Connections The frame is connected to the mains supplies by means of a detachable power cord Rewireable IEC connector supplied Any power cord used should be fitted with su...

Page 5: ... This option is for future development and at present is not supported Pin number Function 1 TD 2 TD 3 RD 4 Not used Internal 75 ohm resistor to GND 5 Not used Internal 75 ohm resistor to GND 6 RD 7 Not used Internal 75 ohm resistor to GND 8 Not used Internal 75 ohm resistor to GND RJ45 Connectors labelled 422 Control and Control loop Pin number Function 1 RX RS422 i p Statesman 2 RX RS422 i p Sta...

Page 6: ...es a connection to these 422 I O ports should share a common GND this will normally occur through the earth pin on the mains connector GPI Connections The High density D type connectors on the rear of the frame contain various outputs associated with other generic frames The outputs that may be off use to the Remind customer are listed below Note 5 0 Vdc maximum 500mA total internally fused by aut...

Page 7: ...o controller on the front panel PCB and the two power supplies have an address and are treated as if they are cards so the reported number of cards available will include the PSUs and front panel The address of the front panel on the first frame is 1 00 and the address of the psu is 1 14 likewise the address of the second frame is 2 00 and the address of the psu is 2 14 Pressing ENTER when these a...

Page 8: ...elled UPPER LOWER on the top edge of the front panel PCB in one frame must be set to LOWER and on the second frame set to UPPER TIA EIA 568A CAT 5 Patch TIA EIA 568A CAT 5 Patch Controlling two frames from a Remind remote panel Using a Remind with existing cabling Where a Remind is used in place of a REM1U an adapter cable will be required to convert the existing 15 way D type connector to an 8 pi...

Page 9: ...o stored inside the connector The fuse can only be accessed when the power cord is disconnected The sequence is as follows Disconnect the power cord from the rear of the frame Using a flat bladed screwdriver or similar tool gently lever out the fuse drawer from the relevant IEC connector using the tab visible at the bottom of the connector depression Remove the defective fuse and replace with eith...