Crystal Vision
Installation
2.4 Connector pinout
Remote control / GPI connections
Each module slot has six connections that are brought out to one or more of the two
high density D-Type connectors on the rear of the frame labelled RMT 1 and RMT 2.
These connections are referred to as lines 'a' to 'f'. The functions assigned to them
are dependent on the module inserted in each slot, but a typical use is as a GPI line.
Refer to the documentation supplied with each Crystal Vision module to determine
the actual functions assigned.
RMT 1 and RMT 2 connections (26-way high density D-Type socket)
Pin number
RMT (Remote) 1 - function
RMT (Remote) 2 - function
1
+5.3V +/- 10% dc out
N/C
2
Frame GND
N/C
3
N/C
N/C
4
N/C
N/C
5
N/C
Relay close on fault on
PSU
6
N/C
Frame GND
7
Slot 2 GPI ‘a’
RX+ RS422 – link bus i/p
8
Slot 1 GPI ‘a’
TX- RS422 Statesman o/p
9
Slot 1 GPI ‘b’
TX+ RS422 Statesman o/p
10
N/C
Slot 2 GPI ‘e’
11
N/C
Slot 2 GPI ‘f’
12
N/C
N/C
13
N/C
N/C
14
N/C
Relay common on PSU
15
N/C
+5.3V +/- 10% dc out
16
Slot 2 GPI ‘b’
RX- RS422 – link bus i/p
17
Slot 2 GPI ‘c’
TX+ RS422 – link bus o/p
18
Slot 1 GPI ‘c’
RX+ RS422 Statesman i/p
19
N/C
Slot 1 GPI ‘e’
20
N/C
Slot 1 GPI ‘f’
21
N/C
N/C
22
N/C
N/C
23
N/C
Relay open on fault on PSU
24
N/C
N/C
25
Slot 2 GPI ‘d’
TX- RS422
26
Slot 1 GPI ‘d’
RX- RS422 Statesman i/p
Note:
The total current available from the 5.3V DC outputs is limited to approximately
1.5 Amps.
To maintain EMC compliance only good quality screened cable assemblies
should be used.
Power supply relay connections
Fitted inside the unit is a relay to indicate if the frame is in an alarm state caused by a
power supply problem, a fan stopping or an overheating frame.
Pinout is as follows:
Description
Pin number
relay common
Remote 2 pin 14
open on fault
Remote 2 pin 23
close on fault
Remote 2 pin 5
Indigo DT User Manual R1.8
8
05 July 2018