3.1 Setting up and connecting
The frame address, which only relates to Indigo DTSE, must be set to zero.
The frame can be connected to a network port or directly to a PC from the rear
panel RJ45 port labelled ‘Ethernet’. Usually, if connecting directly to a modern
computer, a straight CAT5 cable only is needed. A crossover cable might be
necessary with older equipment.
Set the default IP address 10.0.0.201
For Indigo DTSE frames, the configuration switches and status LEDs can be found
on the upper edge of the front panel PCB. To access the internal web page, set the
frame to the default IP address (10.0.0.201) by setting switch S2 on the upper PCB
to the left.
The front panel PCB must now be power cycled in order for changes in the switch
settings to be implemented. This can be achieved by either briefly interrupting the
power to the frame or, if this is not convenient, removing the ribbon-cable
connection to the front panel. Care must be taken not to bend any pins in the cable
connect as attempting to re-straighten any bent pins will likely result in their fracture.
Set the PC’s Local Area Connection (LAN) controller’s sub-mask to 255.255.255.0
and the IP address within the same IP group i.e. 10.0.0.250. For Windows 7 users
this is most easily accessed from the Network and Sharing Centre: