Crystal Vision
Maintenance
9 Maintenance
Warning:
These servicing instructions are for use by qualified personnel only. To
reduce risk of electric shock, do not perform any servicing other than that
contained in the Operating Instructions unless you are qualified to do so.
Refer all servicing to qualified service personnel.
Refer also to the General Safety Summary in the Installation chapter.
9.1 Inserting and removing power supplies
The PSU-160i and PS-80i power supplies can be inserted and removed while the system is
powered without damage. However, this will result in loss of frame power.
Note:
The Indigo 1-DP range can have a single power supply removed without loss of
frame power.
To gain access to the Indigo PSUs proceed as follows:
•
If possible, power down the frame
•
Pull down the front panel using the black knobs at either side of the panel
•
Release the captive screw to the left of the PSU fan
•
Remove the fan assembly by applying sideways pressure on the fan assembly outwards
and towards the right hand frame side
Note:
Take care not to damage the panel ribbon cable when removing the fan
assembly.
Once the fan assembly has been pulled backwards to free the fan connector plug, the PSU
fan will stop and the front panel PSU FAN LED will change from green to red.
The PSU fan assembly
In addition to the PSU and fan LEDs on the front control panel, there is also a red error LED
on the PSU. This LED will flash slowly if there is no fan speed signal present on the fan
connector SK1 caused by the fan removal.
Indigo 1 User Manual R1.14
64