background image

 

 

 

CruizCore

®

 XG1350 USER MANUAL 

 

   

 

Microinfinity reserves all rights in this document and its subject matter. The recipient acknowledges these rights and assures the use of this document only for the purpose it was delivered. 

NOTICE:  We  recommend  extensive  testing  of  this  product  before  using  it  in  a  final 
application.  Specifically,  this  product  should  be  tested  in  the  same  environmental 
conditions  that  it  is  intended  to  be  used.  Furthermore, we  strongly  recommend  caution 
when  using  our  product  in  sensitive  applications  that  can  cause  injures,  death  or 
property  damage  due  to  the  wrong  operation  of  this  product,  which  may  be  caused  by 
unexpected  environmental  changes  such  as  temperature,  shock,  excessive  and 
continuous vibration, etc. These applications include but are not limited to: 

 

Aircraft equipment 

 

Air vehicles 

 

Aerospace equipment 

 

Underwater vehicles 

 

Medical equipment 

 

Transportation equipment 

 

Disaster prevention/crime prevention equipment 

 

Applications which require especially high reliability and accuracy 

 

 

Disclaimer and Limitation of Liability for Damages.   

Microinfinity  shall  not  be  liable,  under  any  circumstances,  for  any  special,  indirect,  incidental, 
consequential,  or  contingent  damages  for  any  reason,  whether  or  not  the  buyer  has  been 
advised of the possibility of such damages. 

 

Summary of Contents for XG1350

Page 1: ...User Manual Rev1 1 CruizCore XG1350 Digital Gyroscope 2013 05 20 Copyright Microinfinity Co Ltd http www minfinity com Contact Info EMAIL support minfinity com TEL 82 31 546 7426 FAX 82 31 546 7409...

Page 2: ...USER MANUAL Microinfinity reserves all rights in this document and its subject matter The recipient acknowledges these rights and assures the use of this document only for the purpose it was delivere...

Page 3: ...is Kit 3 2 3 Cable Pin out 4 2 3 1 USB Cable 4 2 4 Mounting Information Coordinate System 4 2 5 Sensor Start up 5 3 Software Description 6 3 1 Output Data Format 6 3 2 Monitoring Program 6 3 2 1 Insta...

Page 4: ...igure 4 CruizCore XG1350 coordinates system 5 Figure 5 Program main window 6 Figure 6 Rate window 7 Figure 7 Angle window 7 Figure 8 Data window 8 List of Tables Table 1 CruizCore XG1350 part list des...

Page 5: ...0 USER MANUAL Microinfinity reserves all rights in this document and its subject matter The recipient acknowledges these rights and assures the use of this document only for the purpose it was deliver...

Page 6: ...sensors it has the advantage of being light weight small size and consuming low power The XG1350 is packaged in a hard case for increasing protection against external impact The XG1350 uses an adapti...

Page 7: ...ath or property damage due to the wrong operation of this product which may be caused by unexpected environmental changes such as temperature shock excessive and continuous vibration etc These applica...

Page 8: ...on to minimize the power noises The input voltage range of 4 75 V to 5 25 V is acceptable for power supply 2 2 Part List Included with this Kit The CruizCore XG1350 is a full developer s kit intended...

Page 9: ...e System The CruizCore XG1350 coordinate system has its sensitive axis perpendicular to the device flatter area see Figure 4 therefore the gyro will show a positive angular rate and angle increment wh...

Page 10: ...vered 5 2 5 Sensor Start up The CruizCore XG1350 startup time is less than one second it internally compensates for errors due to changes in temperature However sudden temperature changes shortly afte...

Page 11: ...oring program For convenience the program displays the parsed data in numerical and graphical forms and allows saving the data for subsequent analysis The following explanation is based on the Monitor...

Page 12: ...ays the information related to the CruizCore XG1350 in five different formats or windows rate angle acceleration compass and angle acceleration data 3 2 3 Rate Window This window shows the yaw rate of...

Page 13: ...rmat the parsed sensor data and accumulated heading and acceleration data since the sensor was reset see Figure 10 3 2 8 Icon Toolbar The icon toolbar gives access to the most important features and f...

Page 14: ...rt All the Rate and Angle data will be saved Output data filename is Log_ current year month day hour minute second out in Log folder Example Log_20110703084425 out Data Save stop Data save will be st...

Page 15: ...it was delivered 10 4 System Characteristics The following tables summarize the main characteristics of the CruizCore XG1350 These specifications subject to change without notice and several paramete...

Page 16: ...C 95 RH 10h 30 C 2h 75 C 2h 10cycles Refer to Table 5 4 Thermal shock 40 C 85 C 1hour at each temperature 10cycles Refer to Table 5 5 Drop Free drop from 750mm height on a wooden board for 6 times Re...

Page 17: ...RAMETER CONDITION VALUE UNIT Min Typ Max INPUT VOLTAGE OPERATING 4 75 5 25 V RECOMMENDED 5 V CURRENT 5 V 10 mA POWER 5 V 50 mW CAUTION ESD electrostatic discharge sensitive device Electrostatic charge...

Page 18: ...sec FULL ALIGNMENT1 5 min ANGULAR RATE CONTINUOUS 100 deg sec INSTANTANEOUS2 150 deg sec RESOLUTION 0 01 deg sec SCALE FACTOR ERROR 0 5 1 BIAS DRIFT 10 50 deg hr ACCELERATION MEASUREMENT RANGE 2 G DA...

Page 19: ...USER MANUAL Microinfinity reserves all rights in this document and its subject matter The recipient acknowledges these rights and assures the use of this document only for the purpose it was delivere...

Page 20: ...the purpose it was delivered 15 Contact Information Corporate Office Microinfinity Co Ltd 8F KANC 906 10 Iui dong Yeongtong gu Suwon si Gyeonggi do 443 270 Korea Tel 82 31 546 7408 Fax 82 31 546 7409...

Page 21: ...s with your comments about this manual and product 1 What are the best features of this document and product 2 How does this document meet your hardware and software development needs 3 Do you find th...

Reviews:

Related manuals for XG1350