INSTALLATION AND OPERATION MANUAL, ELECTRIC COUNTER CONVECTION
STEAMER, MODELS: SX-3, SX-5
PART NUMBER 10080R5
5
2007-01-02
2.0 INSTALLATION INSTRUCTIONS
GENERAL
The SX-3 and SX-5 steamers are single compartment electric pressureless steam cookers with
an internal electric steam generator that maintains water temperature at approximately 205°F.
SX-3 is rated 7.5 kW as standard; 10 kW is optional. SX-5 is rated 15 kW.
At high altitude locations a lower temperature is required to achieve atmospheric steaming.
Contact your authorized service office to have the thermostat adjusted if the steamer will be
operated at high altitudes.
INSTALLATION
UNPACKING
Immediately after unpacking the steamer, check for possible shipping damage. If the steamer
is found to be damaged, save the packaging material and contact the carrier within 15 days of
delivery.
Prior to installation, verify that the electrical service agrees with the specifications on the
machine data plate which is located on the left side panel.
LOCATION
Allow space for plumbing and electrical connections. Minimum clearances are 2" on the sides
and 6" on the back for proper air circulation. Allow adequate access for operating and servicing
the steamer (36" at the front of the steamer and 15" above the steamer).
LEGS (OPTIONAL)
If the optional 4" adjustable legs are used, remove the four levelling feet on the bottom of the
steamer.
LEVELLING FEET (Standard) OR 4" ADJUSTABLE LEGS (Optional)
Thread the four 2" levelling feet shipped in a bag inside the steamer cabinet into the threaded
holes on the bottom corners of the steamer. Or, thread the four optional 4" adjustable legs into
the threaded holes on the bottom corners of the steamer.