background image

 

INSTALLATION INSTRUCTIONS  

S W A N   C A M    

QUAD ELEMENT PIR & MONO/COLOUR CAMERA MOTION DETECTOR With PET IMMUNITY 

 

 

 

PRODUCT FEATURES 

 
Video sensing device

 

  High sensitivity and high-resolution board 

camera. 

  Electronic shutter control. 

 

Audio sensing device

 

  Omnidirectional response. 

  High sensitivity. 

 

AGC

 

 

  Quad (four element) PYRO sensor and hard 

lens for outstanding detection performance and 
elimination of false alarms. 

  ASIC based electronics with movement speed 

spectrum analysis. 

  User-friendly installation with swivel bracket. 

  BI directional temperature compensation. 

  Environmental immunity. 

  Pet immunity up to 25Kg. Pet active bellow 1m. 

  Height installation calibrations free from 1.8m to 

2.4m. 

  Wide range operating voltage. 

  High reliability and trouble free operation. 

 

SELECT MOUNTING LOCATION 

Choose a location most likely to intercept an intruder. 
(Our recommendation is a corner installation). See 
detection pattern fig.3. The quad-element high quality 
sensor detects motion crossing the beam; it is slightly 
less sensitive detecting motion toward the detector. 
The SWAN CAM performs best when provided with a 
constant and stable environment and background. 
AVOID THE FOLLOWING LOCATIONS 

  Facing direct sunlight. 

  Facing areas that may change temperature 

rapidly. 

 

Areas where there are air ducts or substantial 
airflows.

 

    Fig.1 

 

 

DETECTOR INSTALLATION

 

 

The detector can either be wall, corner or ceiling 
mounted by using special bracket base for the bracket 
mounting. 
Refer to bracket description.  (See fig. 6). 

1. To remove the front cover, unscrew the holding screw 

and gently raise the front cover. (See fig.2). 

2. Insert wire through the bracket and holes “A” and 

“B”. (See fig.1) 

3. Mount the bracket base to the wall or to the ceiling 

with the suitable adaptor. Hold the detector base in 
front of the protected area and tighten the bracket 
screw.  

4. Insert the wires through the bracket and connect the 

wires to the terminal block. 

5. Replace the cover by inserting it back in the 

appropriate closing pins and screw in the holding 
screw. 

 

 

 
 

Fig.2 

 

 

DETECTOR CONNECTION 

 

 

 

Terminal 1 - Marked “ - ” (GND) 

Connect to the negative supply voltage output or ground

  

Terminal 2 - Marked “ + ” (+12V) 

Connect to a positive supply voltage output of 8.2 -
16Vdc source (usually from the alarm control unit) 

 
Terminals 3 & 4 - Marked “ TAMP ”

 

If a Tamper function is required connect these terminals 
to a 24-hour normally closed protective zone in the 
control unit. If the front cover of the detector is opened, 
an immediate alarm signal will be sent to the control 
unit. 

Terminals 5,6 & 7 - Marked 

 N.C, C & N.O 

 

These are the output relay contacts of the detector. 
Connect to a normally closed or normally opened zone 
in the control panel. 

Terminals 8 & 9 - Marked “ AUD ”& “GND” 

This is the audio signal output. These two terminals 
should be connected to an audio input. 

Terminals 9 & 10 - Marked “ GND ”& “VID” 

This is the video signal output. These two terminals 
should be connected to video input.

  

 

 

TESTING THE DETECTOR 

Wait one minute after applying 12Vdc power - warm up

 

time.  
Conduct testing with the protected area cleared of all 
people. 

 
Walk test

 

1.  Remove front cover.                                              
2.  Set LED to ON position. 
3.  Reassemble the front cover. 
4.  Start walking slowly across the detection zone. 
5.  Observe that the LED lights whenever motion is     

detected. 

6.  Allow 5 sec. between each test for the detector to 

stabilize. 

7.  After the walk test is completed, you can set the 

LED to OFF position. 

 
NOTE:

  

Walk tests should be conducted, at least once a year, to 
confirm proper operation and coverage of the detector. 

 

 

 

 

 
 

 

 

 

Fig.3 

 

     

 

 

 
 

Fig.4 