GBD-II

 

SHOCK & BREAKAGE   

GLASS BREAK DETECTOR

 

 
 

                         

 

 

 

 

     

    ELECTRONIC ENGINEERING LTD. 

 

INSTALLATION INSTRUCTIONS 

P/N 7101108

    Ver. 2.0  A.Y.

 

 

The GBD-II is the ultimate answer for all those 
tired of false alarms. It listens for sounds of 
breaking glass, which produce two sequential 
signals of different frequencies. The unique 
phased frequency detection circuitry of this 
detector allows detection of both shock signal 
and the strong signal of glass breakage 
creating a “false alarm free” glass break 
detector. 
The detector does not need to be attached to 
the window, providing volume protection, and 
allowing you to protect several windows with 
one detector. 

FEATURES 

  Phased Frequency Detection system, 

detects low frequency impact sound as well 
as the glass breakage sound thereby 
eliminating false alarms. 

  Separate sound & shock adjustment. 

  Memory function. 

  Volume protection. 

  Ceiling or wall mounting. 

 

FIG. 1 - MOUNTING 

 

 
The detector offers flexible installation. It can 
be Either ceiling mounted or wall mounted as 
shown in the figure above. 

 

 

MOUNTING LOCATION ( See FIG. 1 ) 

  If heavy blinds or curtains cover the glass, 

you must locate the detector behind the 
blinds on the window frame or above it, 
otherwise the blinds might block the sound. 
Make sure to test the unit thoroughly for 
proper detection. 

  Install the detector in a direct line of sight 

with the protected glass. 

  Do not mount the unit in front of air ducts, 

or close to bells (measuring 0.5m (or 
larger) in diameter).

 

  For a few protected glasses in one room, 

locate the detector in optimal distance from 
them to achieve the best detection.

 

 
Note:  

for symmetrical cover of the detection 

area it is recommended to place the 
detector on the ceiling.

 

 

 

MOUNTING THE DETECTOR ( FIG. 2 ) 

1.

  Use a small screwdriver to push the prong 

on top of the case and open the case. 

2.

  There is no need to remove the PCB 

(Printed Circuit Board) from the case. 

3.

  Insert the wires through the wiring hole (B). 

4.

  Use the mounting holes (A) to mount the 

detector. 

5.

  Connect the wires to the terminal.(See 

Terminal Connections) 

6.

  Close the case. 

 

JUMPERS ( FIG. 4 ) 

 

JP1

 - Shock / Glass selector for detection 

calibration. 

 

JP2

 - Reduces the sensitivity of sound 

detection by 50%. 

 

JP3

 - Latch. See The Memory Function. 

 

 

FIG. 2 - THE BACK COVER 

 

A

A

B

 

 

 

FIG. 3 - TERMINAL BLOCK 

 

TERMINAL BLOCK CONNECTIONS 

Terminal 1 - Marked  -  ( -12V ) 

Connect to the negative Voltage output or 
ground of the control panel. 

Terminal 2 - Marked  +  ( +12V ) 

Connect to the positive Voltage output of 9-16 
Vdc

 source (usually from the alarm control unit)

 

Terminals 3 & 4 - Marked  TAMPER   

If a Tamper function is required connect these 
terminals to a 24hour normally closed protective 
zone in the control unit. If the front cover of the 
detector is opened, an immediate alarm signal will 
be sent to the control unit.

 

Terminals 5 & 6 - Marked  RELAY 

 

These are the output relay contacts of the detector. 

    

  

 

 

 
 

 

 

THE CALIBRATION TOOL ( * ) 

The Simulator/Tester & Calibration tool is 
especially designed to check phased 
frequency glass break detectors. 
Since the detector will react to the high 
frequency breakage sound only when it comes 
sequentially after a low frequency SHOCK 
sound, this device is necessary to check for 
proper operation of the GBD-II without actually 
breaking the glass. 

Manual mode

In this mode, the Simulator will emit the high 
frequency sound of breaking glass for "Glass" 
adjustment. 

Automatic mode

In order to simulate breaking glass, place the 
Simulator on the surface of the protected 
glass, and gently hit it with your hand.  The 
Simulator will then emit the sound of breaking 
glass. Be careful not to break the glass while 
testing the detector. 

  It is recommended to use

 

simulator

 

CROW  

P/N: 0040011 

 

TESTING THE DETECTOR 

First use the Simulator in manual mode to 
simulate the noise of glass breaking. Check 
that the yellow LED is ON. If it does not light, 
the sensitivity calibration is necessary (See 
Sound Calibration). 
Now use your hand or a padded object to 
carefully strike the glass. If the green LED 
does not light, adjust as necessary (See 
Shock Calibration). 
Now use the Simulator in automatic mode and 
check that the red LED lights. If the red LED is 
ON, your detector is working properly. 
Otherwise try adjusting the sound and shock 
setting until the red LED lights. 