background image

MANUAL

 

10

077

R

3

INSTALLATION & OPERATION 

MANUAL 

 Direct Steam 

Tilting

 Kettles

DLT-20   DLT-30   DLT-40   DLT-60   DLT-80   DLT-100

DPT-20   DPT-30   DPT-40   DPT-60   DPT-80

WARNING 

Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read 

the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. 

IMPORTANT FOR FUTURE REFERENCE 

Please complete this information and retain this 

manual for the life of the equipment:

 

Model #:   ___________________________  
Serial #:   ___________________________  
Date Purchased:   ____________________  

CROWN FOOD SERVICE EQUIPMENT 

Division of Middleby Canada Company Inc

70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9 

Telephone: 919-762-1000              www.crownsteamgroup.com 

Printed in Canada 

Summary of Contents for DLT-100

Page 1: ...and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipm...

Page 2: ...all safety messages that follow this symbol to avoid possible injury or death WARNING Improper installation operation adjustment alteration service or maintenance can cause property damage injury or d...

Page 3: ...7R3 3 2013 07 16 TABLE OF CONTENTS DESCRIPTION PAGE SERVICE CONNECTIONS DLT 4 SERVICE CONNECTIONS DPT 5 1 0 INSTALLATION INSTRUCTIONS 6 2 0 INTRODUCTION DESCRIPTION 7 3 0 BASIC FUNCTIONING 7 4 0 OPERA...

Page 4: ...INSTALLATION AND OPERATION MANUAL DIRECT STEAM TILTING KETTLES MODELS DLT DPT Part No 10077R3 4 2013 07 16 SERVICE CONNECTIONS...

Page 5: ...INSTALLATION AND OPERATION MANUAL DIRECT STEAM TILTING KETTLES MODELS DLT DPT Part No 10077R3 5 2013 07 16 SERVICE CONNECTIONS...

Page 6: ...base making contact with floor surface to fulfil NSF requirements 6 Connect steam line 3 4 pipe size to the kettle making sure there is a steam control valve strainer fairly convenient to the kettle...

Page 7: ...that kettle in U S gallons Thus a DLT 40 is a two thirds jacketed direct steam kettle mounted on legs with a capacity of 40 gallons U S If the letter F is added to the suffix this indicates that the k...

Page 8: ...steam supply is OFF 2 Pre rinse inside of kettle thoroughly and drain to remove any food particles 3 Using a nylon brush clean kettle with a mild detergent and warm water rinse Never use steel wool or...

Page 9: ...ents that are corrosive Use of cleaning agents that contain chloride acids or salts are corrosive and may cause pitting and corrosion when used over a period of time this will reduce the life of the a...

Page 10: ...lever test should also be performed at the end of any non service period CAUTION Hot high pressure fluid may be discharged from body drain and vent during try lever test Care must be taken to avoid an...

Page 11: ...the rubber vulcanized stem piece has been damaged and must be replaced EXTREMELY SLOW COOKING TIME If the cooking time is abnormally slow then the difficulty may be due to insufficient steam pressure...

Page 12: ...at 30 p s i reaches a temperature of 274 degrees Fahrenheit 135 degrees Celsius Since air is an unsuitable media through which heat may be transferred the air should be exhausted from the jacket by op...

Reviews: