0
B A T C H
I D SERIAL NO
Proof of Performance Report
DCA-11
020163
DC-300A
laboratory power amplifier
Serial Number Line Voltage
Amcron Label
CH.l
1. Quies. offset of less than 1OmV
2. 1 KHz 180 watts RMS minimum into
8 ohms, per channel, both channels
operating, 0.1% total harmonic
distortion
3. 4 ohm test
4. Protection tests
5. Reliability test
6. 20KHz 1 5 5 w a t t s p e r c h a n n e l
minimum RMS (both channels
operating) into 8 ohm. 0.05% total
harmonic distortion
7. 10 KHz. sq. wave
8. Mono operation
9. IM Dist. into 8 ohms (%)
155W
(60-7KHz 4:1) S.M.P.T.E.
49.0W
15.5w
4.9w
1.55w
490mW
155mW
4 9 m W
15.5mW
10. Hum and noise-db below 155W into
8 ohm (20Hz
-
20KHz)
db
CH.2