Crown CRN30 Operating & Installation Instructions Download Page 1

The above sink Boiling Water Unit  dispenses boiling water — Please treat it with care. 

If a tundish is used it must be placed  above the sink in the open. 

IMPORTANT: THIS UNIT MUST BE INSTALLED BY AN AUTHORISED PLUMBER. 

WARNING: 

WE RECOMMEND A BACKFLOW  PREVENTION DEVICE COMPLYING WITH THE REQUIREMENT OF A.S. 3500.1 BE 
INSTALLED ON THE  WATER SUPPLY INLET TO THIS UNIT. 

*Unit to be connected in  accordance with A.S.3500 & A.S.3000 

    

PROUDLY MADE IN AUSTRALIA 

Boiling Water Units 

 

30, 40, 50 & 60 litres 

 

Wall Mounted 

 

Optional Stainless Steel Cover 

 

Simple service if required 

 

No costly parts 

 

1 year warranty 

 

Energy efficient 

 

Standard colour bond finish 

 

OPERATING & INSTALLATION INSTRUCTIONS                              

CELSIUS 100 ABOVE SINK BOILING WATER UNIT. Series JE 

Summary of Contents for CRN30

Page 1: ...VICE COMPLYING WITH THE REQUIREMENT OF A S 3500 1 BE INSTALLED ON THE WATER SUPPLY INLET TO THIS UNIT Unit to be connected in accordance with A S 3500 A S 3000 PROUDLY MADE IN AUSTRALIA Boiling Water Units 30 40 50 60 litres Wall Mounted Optional Stainless Steel Cover Simple service if required No costly parts 1 year warranty Energy efficient Standard colour bond finish OPERATING INSTALLATION INST...

Page 2: ...8 6 0 775 600 250 CRN60 60 300 200 260 4 8 6 0 840 600 250 DO NOT SWITCH ON POWER WITHOUT WATER RUNNING OUT FROM THE TAP POWER MUST BE OFF UNTIL INSTALLATION IS COMPLETE This unit is fitted with a computerised element and boil dry protection Maximum inlet pressure 820 kpa Fit PLV if required Minimum inlet pressure 200 kpa If a lower pressure is encountered refer to manufacturer DO NOT PLUG IN POWE...

Page 3: ... area where water can be disposed of in a safe manner 5 Plug unit into 10 amp power outlet If installing larger 3 6kw element model be sure that lead and plug is 15amp The same as power outlet 6 Turn ON water supply to unit and OPEN the outlet tap 7 Wait until water flows out of the tap 8 When water flows out of the tap please SWITCH THE POWER ON BEFORE USING WE RECOMMEND THE FITTING OF A TRIPPLE ...

Page 4: ...f necessary Remove ball float and check to make sure there is no water in it Replace if necessary CONTINUOUS BOILING BALL VALVE DEFECTIVE FAULTY ELEMENT Ensure ball valve is closed off does not leak Replace if necessary Replace element WATER NOT HOT POWER NOT TURNED ON ELEMENT FAULTY Check if power is ON Check the element is drawing the cor rect current Replace if found to be faulty NO WATER WATER...