background image

T

he Crown

®

 

660A is a six-channel amplifi er 

for commercial and industrial audio. It pro-
vides 4-ohm and constant-voltage outputs 

(70V and 100V) on channels 1 through 4, and 
4-ohm outputs on channels 5 and 6. 

The 660A has six inputs and six 60W power 
amplifi er channels for multi-zone systems. It can 
drive different types of speakers in different areas 
of a facility.

Some applications include schools, hospitals, 
factories, restaurant/retail, houses of worship, 
fi tness facilities, A/V boardrooms, 5.1 surround 
systems, courtrooms, and prisons. Typical uses 
are paging, background music, security and 
evacuation instructions.

The amp is part of Crown’s Commercial Audio 
Series, which also includes mixers and mixer-
amps. These low-cost units provide all necessary 
features in a simple building-block format. 

The sound system can be upgraded as a facility 
expands. For example, you can add more mixers 
for more inputs, or add more power amps (or 
mixer-amps) to handle more zones.

Specifi cations

Performance

Frequency Reponse 

(at 1 watt from 4-ohm tap):

 

70 Hz to 19 kHz +/- 1 dB.

Frequency Response 

(at line out):

 

20 Hz to 20 

kHz +/- 1 dB.

Power Bandwidth 

(at 4-ohm tap, 2 dB below 

maxium 1 kHz power):

 

50 Hz to 20 kHz with 

< 0.5% THD.

Signal to Noise Ratio 

(ref. to rated power, master 

volume at minimum):

 

85 dB.

DC Output Offset:

 < ±5 mV. 

THD:

 Less than 0.5% at rated power at 1 kHz. 

Input Sensitivity 

(for full output at maximum 

gain): 800 mV.

Input Impedance (nominal): 

100 kilohms.

Minimum Load Impedance: 

100V output: 160 ohms.
70V output: 80 ohms.
4-ohm output: 4/8 ohms.

Crosstalk (all controls at “10”):

 –70 dB at 1kHz.

Load Impedance: 

Ch. 1-4: 4 ohms and 70V/100V.
Ch. 5-6: 4 ohms.

AC Line Voltages Available: 

100V  50/60 Hz
120V  60 Hz
220V  50/60 Hz
230V  50/60 Hz
240V  50/60 Hz

AC Voltage Tolerance:

 +10%/–20%.

Operating Temperature/Humidity: 

 0° C to 40° C 

at 95% relative humidity (non-condensing). 

Storage Temperature: 

–20° C to 85° C.

Front Panel Controls and Indicators

Power Switch: 

Pushbutton on-off switch.

Power Indicator:

 Blue LED indicates power on.

Output Signal Presence Indicator: 

Green LED, 

one for each output channel, illuminates when 
output signal level exceeds 100 mV (45 dB below 
full power) from the 4-ohm tap. 

Clip Indicators:

 Red LED, one per output channel. 

Illuminates at threshold of audible distortion. 

Volume Controls:

 One per output channel. 

Detented potentiometer with knob.

Tone Controls:

 Bass and Treble non-detented 

potentiometers on each channel. Bass ±10 dB at 
100 Hz, Treble ±10 dB at 10 kHz.

Back Panel Controls and Connectors

Reset Switch:

 Resets the circuit breaker that 

protects the power supply. 220/230/240V units 
have a fuse instead.

Input Connectors:

 Detachable 3-pin Phoenix-type, 

high-impedance balanced, one per channel.

AC Power Inlet:

 Detachable IEC. 

Amplifi er Outputs Connectors:

 One per channel, 

4-position terminal strip with COM (Common), 4 
ohms, 70V and 100V terminals for channels 1-4 
and one 4-position terminal strip (4 ohms, + and 
– for each channel) for channels 5 and 6. Accepts 
up to 10 AWG terminal forks. Non-touch cover 
included.

VCA Connector:

 Each pair of channels has a 4-pin 

Phoenix-type connector for two VCA control lines 
of +10 VDC and ground. Compatible with Crown 
1-VCAP and 4-VCAP modules. 

Cooling

Convection cooled.

Protection

Current Limit Protection: 

Included.

Thermal Limit Protection: 

Over-temperature 

thermal cutout.

DC-Fault Load Protection:

 Included.

Turn On/Turn Off:

 No thumps or pops.

Included Accessories 

Power cord
Detachable rack ears
Screws for rack ears
Non-touch cover for output connectors
Phoenix-type connectors
Spade lugs

C O M M E R C I A L   A U D I O   S E R I E S 

•  Six inputs, six 60W amplifi er output channels; 

4-ohm and 70V/100V outputs 

•  Ideal for commercial and industrial use

•  Balanced Phoenix-type line inputs; touch-

proofed screw-terminal speaker outputs

•  Advanced protection system includes 

output current limiting, DC protection, cir-
cuit breaker/fuse, and thermal protection; 
details available online at www.crownau-
dio.com

•  Three-Year, No-Fault, Fully Transferable 

Warranty completely protects your invest-
ment and guarantees its specifi cations

Features

1 kHz 
Power

60W

Minimum guaranteed power 
into 4 ohms or 70V/100V
output

660A

*1 kHz Power: refers to maximum power in watts at 
1 kHz with 0.5% THD.

*

660A

Reviews: