Page 59
CDi DriveCore Series Operation Manual
Using the AUX Port
Page 59
Using the AUX Port
Using the AUX Port
The AUX port can be used for basic monitoring of the amplifier and for remote standby (sleep). The port is shared with the GPIO using an 8-pin block
connector, with pin 6 used as ground.
Sleep
The amplifier can be put to sleep by connecting pins 6 and 8 together on the AUX port. When applying this connection, the amplifier will shut down and
remain asleep until the connection between pins 6 and 8 is opened. When the connection between pins 6 and 8 is open, the amplifier will revert to its last
configuration and begin to output audio within ~15 seconds. Network communication will be re-established once the network interface card boots. While
the amplifier is asleep, the front panel
POWER
button is disabled and, if pressed, the blue power indicator will blink briefly to indicate the device is asleep.
Sleep Closed
SERIAL NUMBER
SERIAL NUMBER
BAR CODE
100-240V
~
50/60Hz 350W
1718 W. MISHAWAKA RD.
ELKHART IN 46517 USA
CAUTION - TO REDUCE THE RISK OF ELECTRIC
SHOCK, GROUNDING OF THE CENTER PIN
OF THIS PLUG MUST BE MAINTAINED
ATTENTION - POUR RÉDUIRE LE RISQUE DE CHOC
ÉLECTRIQUE LA FICHE CENTRALE LA PRISE DOIT ÊTRE
BRANCHÉE POUR MAINTENIR LA MISE À LA TERRE
WARNING
-
TO REDUCE THE RISK
OF FIRE OF ELECTRICAL SHOCK, DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
AVERTISSEMENT
- ENERGIE
ELECTRIQUE DANGEREUSE` VOIR LE
CAHIER D’INSTRUCTIONS.
APPARATET MA TILKOPLES JORDET
STIKKONTAKT.
APPARATEN SKALL ANSLUTAS TILL
JORDAT UTTAG.
LAITE ON LIITETTÄVÄ
SUOJAKOSKETTIMILLA
VARUSTETTUUN PISTORASIAAN.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVERTISSEMENT:
RISQUE DE CHOC
ELECTRIQUE - NE PAS OUVRIR
CLASS 2 OUTPUT WIRING PERMITTED.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING CONDITIONS.
1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE.
2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
WARNING
OUTPUT
OUTPUT
INPUT
2
1
4
3
2
1
DUAL
DUAL
BRIDGE
OUTPUT
WIRING
ETHERNET
100Mb
ACT
GPIO/AUX
BLU link
IN
OUT
OUT
1
2
IN
3
AMP
S
TA
TUS
7
+3.
3V
4
5
IN
6
SL
EEP
8
Sleep Open
SERIAL NUMBER
SERIAL NUMBER
BAR CODE
100-240V
~
50/60Hz 350W
1718 W. MISHAWAKA RD.
ELKHART IN 46517 USA
CAUTION - TO REDUCE THE RISK OF ELECTRIC
SHOCK, GROUNDING OF THE CENTER PIN
OF THIS PLUG MUST BE MAINTAINED
ATTENTION - POUR RÉDUIRE LE RISQUE DE CHOC
ÉLECTRIQUE LA FICHE CENTRALE LA PRISE DOIT ÊTRE
BRANCHÉE POUR MAINTENIR LA MISE À LA TERRE
WARNING
-
TO REDUCE THE RISK
OF FIRE OF ELECTRICAL SHOCK, DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
AVERTISSEMENT
- ENERGIE
ELECTRIQUE DANGEREUSE` VOIR LE
CAHIER D’INSTRUCTIONS.
APPARATET MA TILKOPLES JORDET
STIKKONTAKT.
APPARATEN SKALL ANSLUTAS TILL
JORDAT UTTAG.
LAITE ON LIITETTÄVÄ
SUOJAKOSKETTIMILLA
VARUSTETTUUN PISTORASIAAN.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVERTISSEMENT:
RISQUE DE CHOC
ELECTRIQUE - NE PAS OUVRIR
CLASS 2 OUTPUT WIRING PERMITTED.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING CONDITIONS.
1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE.
2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
WARNING
OUTPUT
OUTPUT
INPUT
2
1
4
3
2
1
DUAL
BRIDGE
OUTPUT
WIRING
ETHERNET
100Mb
ACT
GPIO/AUX
BLU link
IN
OUT
OUT
1
2
IN
3
AMP
S
TA
TUS
7
+3.
3V
4
5
IN
6
SL
EEP
8
Amp Status
Amp Status can be used for basic monitoring of the amplifier. Monitoring of the amplifier can determine if the amplifier is operating within optimal
parameters, or if the amplifier has been shut off or is in fault. Between pins 6 and 7, there will be either a +5VDC potential or a 2Hz square wave (heart
beat). This option can be set from the Amp Info panel in Audio Architect, see
"Amplifier Information" on page 32
.
Amp Status Closed
SERIAL NUMBER
SERIAL NUMBER
BAR CODE
100-240V
~
50/60Hz 350W
1718 W. MISHAWAKA RD.
ELKHART IN 46517 USA
CAUTION - TO REDUCE THE RISK OF ELECTRIC
SHOCK, GROUNDING OF THE CENTER PIN
OF THIS PLUG MUST BE MAINTAINED
ATTENTION - POUR RÉDUIRE LE RISQUE DE CHOC
ÉLECTRIQUE LA FICHE CENTRALE LA PRISE DOIT ÊTRE
BRANCHÉE POUR MAINTENIR LA MISE À LA TERRE
WARNING
-
TO REDUCE THE RISK
OF FIRE OF ELECTRICAL SHOCK, DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
AVERTISSEMENT
- ENERGIE
ELECTRIQUE DANGEREUSE` VOIR LE
CAHIER D’INSTRUCTIONS.
APPARATET MA TILKOPLES JORDET
STIKKONTAKT.
APPARATEN SKALL ANSLUTAS TILL
JORDAT UTTAG.
LAITE ON LIITETTÄVÄ
SUOJAKOSKETTIMILLA
VARUSTETTUUN PISTORASIAAN.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVERTISSEMENT:
RISQUE DE CHOC
ELECTRIQUE - NE PAS OUVRIR
CLASS 2 OUTPUT WIRING PERMITTED.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING CONDITIONS.
1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE.
2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
WARNING
OUTPUT
OUTPUT
INPUT
2
1
4
3
2
1
DUAL
DUAL
BRIDGE
OUTPUT
WIRING
ETHERNET
100Mb
ACT
GPIO/AUX
BLU link
IN
OUT
OUT
1
2
IN
3
AMP
S
TA
TUS
7
+3.
3V
4
5
IN
6
SL
EEP
8
Amp Status Open
SERIAL NUMBER
SERIAL NUMBER
BAR CODE
100-240V
~
50/60Hz 350W
1718 W. MISHAWAKA RD.
ELKHART IN 46517 USA
CAUTION - TO REDUCE THE RISK OF ELECTRIC
SHOCK, GROUNDING OF THE CENTER PIN
OF THIS PLUG MUST BE MAINTAINED
ATTENTION - POUR RÉDUIRE LE RISQUE DE CHOC
ÉLECTRIQUE LA FICHE CENTRALE LA PRISE DOIT ÊTRE
BRANCHÉE POUR MAINTENIR LA MISE À LA TERRE
WARNING
-
TO REDUCE THE RISK
OF FIRE OF ELECTRICAL SHOCK, DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
AVERTISSEMENT
- ENERGIE
ELECTRIQUE DANGEREUSE` VOIR LE
CAHIER D’INSTRUCTIONS.
APPARATET MA TILKOPLES JORDET
STIKKONTAKT.
APPARATEN SKALL ANSLUTAS TILL
JORDAT UTTAG.
LAITE ON LIITETTÄVÄ
SUOJAKOSKETTIMILLA
VARUSTETTUUN PISTORASIAAN.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVERTISSEMENT:
RISQUE DE CHOC
ELECTRIQUE - NE PAS OUVRIR
CLASS 2 OUTPUT WIRING PERMITTED.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING CONDITIONS.
1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE.
2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
WARNING
OUTPUT
OUTPUT
INPUT
2
1
4
3
2
1
DUAL
DUAL
BRIDGE
OUTPUT
WIRING
ETHERNET
100Mb
ACT
GPIO/AUX
BLU link
IN
OUT
OUT
1
2
IN
3
AMP
S
TA
TUS
7
+3.
3V
4
5
IN
6
SL
EEP
8
Summary of Contents for 2/300
Page 91: ......