background image

1  2  3 

TL - 360 

 

4 ELEMENT 

CEILING MOUNT 

PASSIVE INFRARED DETECTOR 

 
 

                                             

 

TALON SERIES

 

 

INSTALLATION INSTRUCTIONS 

P/N 7111069 REV.1   A.Y.

 

 

TL-360 FEATURES “Super Catch” 

∗ 

Fully sealed sensor chamber. 

∗ 

VLSI Technology (Very Large Scale 
Integration). 

∗ 

Maximum RFI & EMI Immunity. 

∗ 

4 Element Pyro Sensor. 

∗ 

Pulse Count. 

∗ 

Sophisticated signal processing. 

∗ 

Memory function. 

∗ 

Hard Spherical Lens 360

°

 coverage. 

∗ 

Bidirectional temperature 
compensation. 

∗ 

Flourescent light stability. 

  

INTRODUCTION 

The TL-360 is a 4-element passive infrared 
intrusion detector for use in electronic 
security systems in ceiling mount 
applications. 
You will obtain optimum performance from 
your TL-360 PIR detector by following this 
manual. 

 

 

The TL-360 reduces false alarms to an 
unprecedented minimal level due to its 
effective elimination of background noises 
and nuisance stimuli. The TL-360 employs 
Automatic Pulse Count making it extremely 
adaptable to various environments. The 
unique VLSI, using sophisticated signal 
processing, makes this detector virtually 
free of false alarms. 

The TL-360 integrates VLSI & SMD (surface 
mount device) to their full advantage. 

The detector is easy to install, with no 
necessary adjustments. 

HARD SPHERICAL LENS 

The TL-360 is equipped with a special hard 
lens. This lens is the latest development in 
the security field and complies with all the 
new standards requirements. It gives wide 
coverage patterns, even at low mounting 
heights. It is especially immune to sunlight, 
halogen lights and fluorescent lights and is 
impervious to attack. 

 

4  5  6 

MOUNTING THE DETECTOR 

Choose location most likely to intercept an 
intruder. Refer to the detection  pattern. 

1.  Hold the detector in your hand and 

release the mounting plate by turning 
it counter-clock-wise, and separate it 
from the case (Fig. 1). 

2.  Insert the wires through the hole in the 

center of the mounting plate (Fig. 2). 

3.  Mount the plate using the holes 

marked mounting holes. 

WIRE SIZE REQUIREMENTS 

Use #22 AWG (0.5 mm) or wires with a 
larger diameter. Use the following table to 
determine required wire gauge (diameter) 
and length of wire between the detector 
and the control panel. 
Wire Length        m  200   300    400    800 
Wire Diameter   mm  .5     .75     1.0     1.5 
Wire Length        ft. 800  1200  2000  3400 
Wire Gauge        #    22     20      18      16 

 

FIG. 1 - TL-360 . EXTERNAL VIEW 

 

 

 

 

FIG. 2 - TL-360. INTERNAL VIEW 

 
 

 

 

7  8  9 

TERMINAL BLOCK CONNECTIONS 

 

 

 

 
Run the cable through the cable entry hole 
and connect the wires in accordance with 
the following instructions:

 

Terminal 1 - Marked “ - ” ( GND ) 

Connect to ground of the control panel. 

Terminal 2 - Marked “ + ” ( + 12V ) 

Connect to a positive Voltage output of 
8.2-16 Vdc source (usually from the alarm 
control unit). 

Terminals 3 & 4 - Marked “ RELAY ”

 

These are the output relay contacts of the 
detector. Connect  to a normally closed 
zone in the control panel. 

Terminals 5 & 6 - Marked “ TAMPER ”  

If a Tamper function is required connect

 

 

these terminals to a 24 hour normally 
closed protective zone in the control unit. If 
the front cover of the detector is opened, 
an immediate alarm signal will be sent to 
the control unit. 

Terminal 7 - Marked “ MEM ”

 

The alarm memory function allows the 
identification of an alerting detector out of 
multiple detectors connected to one (or the 
same) zone of the control unit.

 

To enable this function, connect (switch 
on) the M terminal to a sw12 to 
+16V

DC 

source (e.g. Arm / Disarm voltage 

output from the control unit.) 

In case of an alarm, the memory function 
stores the alarm event in the detector. 

 

To identify the detector that alarmed, 
disconnect (switch off) (grounded) the 
voltage from MEM terminal. 

The LED of the detector with the alarm 
event in memory will light constantly until 
memory function is reset. 

To reset the memory function, switch on 
and switch off the M terminal.

 

 

 

PULSE COUNT

 

SETTING - Slide switch

 

(Fig.3). Provides control for normal or  high 
risk operating environments. 

Position 1 (to left) 

For stable environments. 

Position AUTO (to right) 

For harsh environments. 
This setting enables special software to 
modify detection  speed. 
When an intrusion is detected, the LED will 
activate  and the alarm relay will switch into 
alarm condition (open circuit) for 1.6 sec. 
To change position of the slide switch you 
have to open the detector: 

1.  Turn the detector counter-clock wise 

and separate it from the mounting base. 

2.  Change position of the slide switch. 
3.  Close the detector and reinstall 

assembly screws. 

 

 

   1    2     3    4    5    6    7

 

12VDC    RELAY   TAMPER  MEM

 

-    +      

 

NC

 

NC      MEM     

 

Pulse Count 
Switch 

Sensitivity/Range 
Adjustment 

Rubber 
Insulation 

Terminal Strip 

OPEN

 

CLOS

O

 

C

 

Separate cover 
from base 