TEMPERATURE SENSOR
PRODUCT FEATURES
DETECTOR OPENING
KNOCKOUT HOLES
The SH-TEMP-PRB-XT is an advanced temperature sensor
with integrated RF transceiver designed to be a fully
supervised low-current device.
The SH-TEMP-PRB-XT is a part of the FREEWAVE2 devices
that uses an advanced 2way RF transceiver combined with
an intelligent communication protocol.
Temperature over the external sensor by using unique cord
with NTC connected to the external input (e.g. measure
freezer internal temperature)
Temperature measurements are transmitted to the control
panel.
Each SH-TEMP-PRB-XT has a unique factory set ID code
(24bit) which by registration is set into memory of the paired
FREEWAVE2 TRANSCEIVER, enabling more secured
communication
and devices be remotely controlled from a
specific transceiver.
Figure 1
Unscrew the holding screw and remove the front cover
Gently twist the PCB board to disengage it from the
plastic cover.
Figure 2
Detector mounting:
Place the screws and make sure you tighten the tamper
screw (middle screw) easily, so the back tamper switch will
press the switch successfully when the PCB placed back.
INSTRUCTION MANUAL
P/N 7105965 Rev B (D.Z)
DEVICE OVERVIEW
PAIRING PROCESS
BATTERY INSERTION
SENSOR LED DESCRIPTION
Figure 3
For pairing process, please refer to your control panel instructions.
To pair your device with Control panel, please proceed as follows:
1.
Login installer mode via the "Installer Webpage"
2.
Go to "Zones" and select the zone # you want to learn
1.
Add Zone -Type “
ISM
”, insert device
SN. (device’s ID)
The system automatically detects the device type
“
Temperature
”
2.
Set the detector configuration:
“Refrigerated storage” - Pre-set temperatures
“Room temperature” - Pre-set temperature
“Custom” – Temperature setting according to customer
requirement, Please see more details in this manual section
THRESHOLD SETTINGS.
save configuration.
3.
Place a battery as instructed in Figure 4 and wait until the Red
/ Green LED stops blinking.
4.
The device should register to the Control Panel.
5.
When registration process is successfully completed, the Green
LED will constantly light ON for 3 seconds and then turn OFF.
6.
If Green LED continues flashing more than 5 minutes and
stopped, please check the SH-TMP SN, remove battery and
repeat steps 3, 4 and 5.
7.
In order to receive alarm of High/Low temp’ and warning, the
working mode should set “24 hour auto reset”.
8.
Please see
THRESHOLD SETTINGS
for device configuration
Figure 4
Insert the supplied battery into the battery by respecting
polarity.
LED on device will start blinking. Please refer to above
para "Learning process" for device registration.
GREEN / RED Led flashes 6 times alternately:
Sensor has been successfully registered into the control
panel.
The cover may be placed back and closed.
GREEN Led blinks 20 times
:
Device is not registered into the control panel.
Please refer to above para. "Pairing Process" for pairing
instructions.
RED Led blinks continually (over 20 seconds):
Battery voltage is critically low.
The device may not work correctly. Please refer to para.
"Battery Replacement" below.