SH-MAG-SHOCK-8F/9F 

TWO WAY WIRELESS 

MAGNETIC DOOR/WINDOW CONTACT 

& SHOCK DETECTOR 

 

PRODUCT FEATURES 

DETECTOR OPENING 

CIRCUIT LAYOUT 

 

The SH-MAG provide perimeter protection for premises with 

early warning upon attempted intrusion. 
SH-MAG & SHOCK device analyzes shocks while ignoring 

background vibrations. It can be configured Over-The-Air and 

feature a 5 year battery life. 

 

  Freewave2™ Two Way ISM 

 

GFSK with 5 frequencies & LBT

 

  Immunity to attenuation feature 

  Powered by 1 Lithium batteries 3.0V Size CR123 

  Contact Open/Close transmission 

  Shock detection transmission 

  Tamper Open/Close transmission 

  Battery life up to 5 years 

 

Operating Frequencies: 868MHz or 916MHz

 

  Event Transmission: 

Alarm  
Tamper Open/Close 
Supervision 
Battery status 

  Bi-Color LED indications  

  Up to 500m transmission range in open space 

  Remotely configurable 

 

 

 

 

Figure 1 

Pull out the detector cover 

 

 

 

 

Figure 2

 

Remove the batteries cover 

 

 

INSTRUCTION MANUAL

 

P/N 7101689_C 

 

BATTERY INSERTION 

DETECTOR MOUNTING 

LEARNING PROCESS 

 

 

 

 

Figure 3

 

 

 

Batteries can be replaced by the user 

Battery type: 

Lithium. 3V Type: CR123A   Size: 2/3AA

 

 

 
 

 

 

 

 

Figure 4

 

 

Place the Magnet unit near this marking

 

 

 

 

 

 

Figure 5 

Basic installation at 10mm between FW2-Mag and Magnet Unit. 

 
 
 

Configurations 

Axis 

Removal Distance 

(mm) 

Approach Distance 

(mm) 

Wood 

15 

12 

20 

17 

35 

260 

Iron 

10 

17 

14 

32 

28 

 

 

For pairing process, please refer to your control panel 

instructions. 

 

To pair your device with Shepherd

 panel, please proceed 

as follows: 

 

1.  Enter in installing mode via the "Installer Webpage" 

 

2.  Go to "Zones" and select the zone # you want to learn 

 

1.  Add Zone -(Reminder: insert Link Type “

ISM

” , device’s 

ID

, Device Type “

Magnetic & vibration sensor

”.) 

2.  Set the detector configuration: supervision time, VIB 

sensitivity, and save configuration. 

 

3.  Place a battery as instructed in Figure 3 and wait until 

the Red / Green LED stops blinking. 

 

4. The device should register to the Control Panel. 

 

5. When registration process is successfully completed, the 

Green LED will constantly light ON for 3 seconds and 

then turn OFF. 

 

6. If Green LED continues flashing more than 5 minutes 

and stopped, please check MAG-SHOCK settings 

details, remove battery and repeat steps 3,4,5. 

 

7. If Led flashes green constantly , please check if  device’s 

ID is correct or missing. 